A Six Degree of Freedom Head Acceleration Measurement Device for Use in Football
The DOI matches its Crossref record.
Abstract
The high incidence rate of concussions in football provides a unique opportunity to collect biomechanical data to characterize mild traumatic brain injury. The goal of this study was to validate a six degree of freedom (6DOF) measurement device with 12 single-axis accelerometers that uses a novel algorithm to compute linear and angular head accelerations for each axis of the head. The 6DOF device can be integrated into existing football helmets and is capable of wireless data transmission. A football helmet equipped with the 6DOF device was fitted to a Hybrid III head instrumented with a 9 accelerometer array. The helmet was impacted using a pneumatic linear impactor. Hybrid III head accelerations were compared with that of the 6DOF device. For all impacts, peak Hybrid III head accelerations ranged from 24 g to 176 g and 1,506 rad/s 2 to 14,431 rad/s 2. Average errors for peak linear and angular head acceleration were 1% ± 18% and 3% ± 24%, respectively. The average RMS error of the temporal response for each impact was 12.5 g and 907 rad/s 2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rotational Head Kinematics in Football Impacts: An Injury Risk Function for Concussion
Rowson, S., Duma, S. M., Beckwith, J. G., Chu, J. J., Greenwald, R. M., Crisco, J. J., Brolinson, P. G., Duhaime, A.-C., McAllister, T. W., & Maerlender, A. C. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0392-4 · Cited by 491
Self-citationRowson, S., & Duma, S. M. (2013) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0731-0 · Cited by 392
Self-citationRowson, S., & Duma, S. M. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0322-5 · Cited by 290
Self-citationMeaney, D. F., Morrison, B., & Dale Bass, C. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4026364 · Cited by 247
Head-Impact–Measurement Devices: A Systematic Review
O'Connor, K. L., Rowson, S., Duma, S. M., & Broglio, S. P. (2017) · Journal of Athletic Training · doi:10.4085/1062-6050.52.2.05 · Cited by 210
Self-citationBeckwith, J. G., Greenwald, R. M., & Chu, J. J. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0422-2 · Cited by 204
Self-citationSix Degree-of-Freedom Measurements of Human Mild Traumatic Brain Injury
Hernandez, F., Wu, L. C., Yip, M. C., Laksari, K., Hoffman, A. R., Lopez, J. R., Grant, G. A., Kleiven, S., & Camarillo, D. B. (2015) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1212-4 · Cited by 197
Siegmund, G. P., Guskiewicz, K. M., Marshall, S. W., DeMarco, A. L., & Bonin, S. J. (2016) · Annals of Biomedical Engineering · doi:10.1007/s10439-015-1420-6 · Cited by 145
Nano-Composite Foam Sensor System in Football Helmets
Merrell, A. J., Christensen, W. F., Seeley, M. K., Bowden, A. E., & Fullwood, D. T. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-017-1910-9 · Cited by 19
Metadata
- Authors
- Rowson, S., Beckwith, J. G., Chu, J. J., Leonard, D. S., Greenwald, R. M., & Duma, S. M.
- Venue
- Journal of Applied Biomechanics
- Publisher
- Human Kinetics
- Published
- 2011-02
- Volume
- 27
- Issue
- 1
- Pages
- 8-14
- ISSN
- 1065-8483 (ISSN-L)
- 1543-2688
- OpenAlex
- W2125746892
- Cited by
- 142
- References
- 0
- FWCI
- 13.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.