Validity and Comparability of a Wrist-Worn Accelerometer in Children
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: Wrist-worn accelerometers may provide an alternative to hip-worn monitors for assessing physical activity as they are easier to wear and may thus facilitate long-term recordings. The current study aimed at a) assessing the validity of the Actiwatch (wrist-worn) for estimating energy expenditure, b) determining cut-off values for light, moderate, and vigorous activities, c) studying the comparability between the Actiwatch and the Actigraph (hip-worn), and d) assessing reliability. Methods: For validity, indirect calorimetry was used as criterion measure. ROC-analyses were applied to identify cut-off values. Comparability was tested by simultaneously wearing of the 2 accelerometers during free-living condition. Reliability was tested in a mechanical shaker. Results: All-over correlation between accelerometer output and energy expenditure were found to be 0.80 (P < .001).Based on ROC-analysis, cut-off values for 1.5, 3, and 6 METs were found to be 80, 262, and 406 counts per 15 s, respectively. Energy expenditure estimates differed between the Actiwatch and the Actigraph (P < .05). The intra- and interinstrument coefficient of variation of the Actiwatch ranged between 0.72% and 8.4%. Conclusion: The wrist-worn Actiwatch appears to be valid and reliable for estimating energy expenditure and physical activity intensity in children aged 8 to 10 years.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Role of Nonexercise Activity Thermogenesis in Resistance to Fat Gain in Humans
Levine, J. A., Eberhardt, N. L., & Jensen, M. D. (1999) · Science · doi:10.1126/science.283.5399.212 · Cited by 997
Cited by
Age Group Comparability of Raw Accelerometer Output from Wrist- and Hip-Worn Monitors
HILDEBRAND, M., VAN HEES, V. T., HANSEN, B. H., & EKELUND, U. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000289 · Cited by 1,043
Self-citationEstimating Activity and Sedentary Behavior from an Accelerometer on the Hip or Wrist
ROSENBERGER, M. E., HASKELL, W. L., ALBINALI, F., MOTA, S., NAWYN, J., & INTILLE, S. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31827f0d9c · Cited by 237
“No comparison was made with data collected at the hip (10).”
Identifying Children’s Nocturnal Sleep Using 24-h Waist Accelerometry
BARREIRA, T. V., SCHUNA, J. M., MIRE, E. F., KATZMARZYK, P. T., CHAPUT, J.-P., LEDUC, G., & TUDOR-LOCKE, C. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000486 · Cited by 163
“E P ID E M IO LO G Y measure physical activity and sedentary behavior in children with relative success (3,10,11).”
BackgroundDev, M. K., Black, A. A., Cuda, D., & Wood, J. M. (2022) · Translational Vision Science & Technology · doi:10.1167/tvst.11.3.21 · Cited by 10
Metadata
- Authors
- Ekblom, O., Nyberg, G., Bak, E. E., Ekelund, U., & Marcus, C.
- Venue
- Journal of Physical Activity and Health
- Publisher
- Human Kinetics
- Published
- 2012-03
- Volume
- 9
- Issue
- 3
- Pages
- 389-393
- ISSN
- 1543-3080 (ISSN-L)
- 1543-5474
- OpenAlex
- W4297902384
- Cited by
- 99
- References
- 1
- FWCI
- 4.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validity and Comparability of a Wrist-Worn Accelerometer in Children. https://app.cochat.ai/papers/10.1123/jpah.9.3.389
- The paper
- Ekblom, O., Nyberg, G., Bak, E. E., Ekelund, U., & Marcus, C. (2012). Validity and Comparability of a Wrist-Worn Accelerometer in Children. Journal of Physical Activity and Health. https://doi.org/10.1123/jpah.9.3.389
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.