Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.

In operando x-ray imaging of nanoscale devices: Composition, valence, and internal electrical fields

Open access
Johannes, Andreas, Salomon, Damien, Martinez-Criado, Gema, Glaser, Markus, Lugstein, Alois, Ronning, Carsten · 2017 · Science Advances

Abstract

Unrivaled XANES imaging resolution of <100 nm, XANES and XBIC conclusively identify the active area of a nanowire device.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1126/sciadv.aao4044

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Composition of the nanowire heterostructure. Composition of the nanowire heterostructure. (A) Schematic illustration of the device and measurement approach. (B) Scanning electron microscopy (SEM) image with a superimposed color plot of the Kα-XRF intensities of the heavy elements in the Si-Ga-GaAs-Si nanowire heterostructure device with Ni contacts. (C) Normalized XRF intensities plotted as a function of position along the wire. The Ga/(Ga + As) ratio is 0.5 at the GaAs segment (highlighted in green) and approaches 1 at one end of the GaAs segment (highlighted in red). The numbered arrows in (C) indicate the position on the nanowire axis, where the XRF spectra of single pixels shown in (D) were measured.
Fig. 1 Composition of the nanowire heterostructure. Composition of the nanowire heterostructure. (A) Schematic illustration of the device and measurement approach. (B) Scanning electron microscopy (SEM) image with a superimposed color plot of the Kα-XRF intensities of the heavy elements in the Si-Ga-GaAs-Si nanowire heterostructure device with Ni contacts. (C) Normalized XRF intensities plotted as a function of position along the wire. The Ga/(Ga + As) ratio is 0.5 at the GaAs segment (highlighted in green) and approaches 1 at one end of the GaAs segment (highlighted in red). The numbered arrows in (C) indicate the position on the nanowire axis, where the XRF spectra of single pixels shown in (D) were measured.CC BY-NC · PubMed Central
Fig. 2 Simultaneous XRF and XBIC recording. (A) 2D mapping of the Ga/(Ga + As) ratio, normalized XRF signal of (Ga + As), and XBIC at −0.7-V bias; each pixel is 20 × 20 nm2. In the line scan (B) extracted from the maps, the colored background indicates the Si (white), Ga (red), and GaAs (green) sections of the heterostructure as identified by XRF. (C) I-V characteristics of this device in logarithmic (top) and linear scale (bottom). The black hollow circles show the current without x-ray nanobeam (that is, dark conditions), whereas the red filled circles represent the maximum current found when the x-ray nanobeam was focused on the active area of the device.
Fig. 2 Simultaneous XRF and XBIC recording. (A) 2D mapping of the Ga/(Ga + As) ratio, normalized XRF signal of (Ga + As), and XBIC at −0.7-V bias; each pixel is 20 × 20 nm2. In the line scan (B) extracted from the maps, the colored background indicates the Si (white), Ga (red), and GaAs (green) sections of the heterostructure as identified by XRF. (C) I-V characteristics of this device in logarithmic (top) and linear scale (bottom). The black hollow circles show the current without x-ray nanobeam (that is, dark conditions), whereas the red filled circles represent the maximum current found when the x-ray nanobeam was focused on the active area of the device.CC BY-NC · PubMed Central
Fig. 3 Position-resolved Ga-edge XANES spectra measured on a nanoscale along the nanowire heterostructure. (A) The lower group of spectra (1 blue→10 red) shows the normalized, averaged data offset according to their position along the nanowire. The top four graphs (green, red, blue, and dark blue) show the spectra of reference materials, as indicated in the legend (6, 27). The inset SEM image is overlaid with a color plot indicating the points from which the respective XANES spectra (1 to 10) were extracted. The green vertical line indicates the absorption edge of Ga in GaAs. Relative to this line, the black horizontal lines and the bar graph in (B) indicate the shift of the measured absorption edge as a function of the position along the nanowire. (C) Normalized fractions of a linear combination analysis of the measured XANES spectra using the reference materials.
Fig. 3 Position-resolved Ga-edge XANES spectra measured on a nanoscale along the nanowire heterostructure. (A) The lower group of spectra (1 blue→10 red) shows the normalized, averaged data offset according to their position along the nanowire. The top four graphs (green, red, blue, and dark blue) show the spectra of reference materials, as indicated in the legend (6, 27). The inset SEM image is overlaid with a color plot indicating the points from which the respective XANES spectra (1 to 10) were extracted. The green vertical line indicates the absorption edge of Ga in GaAs. Relative to this line, the black horizontal lines and the bar graph in (B) indicate the shift of the measured absorption edge as a function of the position along the nanowire. (C) Normalized fractions of a linear combination analysis of the measured XANES spectra using the reference materials.CC BY-NC · PubMed Central
Fig. 4 Energy-dependent XBIC analysis. (A) Simultaneously recorded Ga XRF (red) and XBIC (black, standardized; blue, as measured) signals as a function of x-ray energy. The insets show an SEM image overlaid with the map of the sum of the respective signal for all energies. The black square in the inset maps indicated the four pixels averaged to give the plotted spectra. (B) Band diagram showing the principal excitation mechanisms of absorption and inelastic scattering. (C) Main charge amplification process of impact ionization. Note that the de-excitation cascade of a single absorption event leads to a large number of charge carriers.
Fig. 4 Energy-dependent XBIC analysis. (A) Simultaneously recorded Ga XRF (red) and XBIC (black, standardized; blue, as measured) signals as a function of x-ray energy. The insets show an SEM image overlaid with the map of the sum of the respective signal for all energies. The black square in the inset maps indicated the four pixels averaged to give the plotted spectra. (B) Band diagram showing the principal excitation mechanisms of absorption and inelastic scattering. (C) Main charge amplification process of impact ionization. Note that the de-excitation cascade of a single absorption event leads to a large number of charge carriers.CC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 41 references

Research works printed but not linked: 1

  1. A. Kaneko A. Yagishita K. Yahashi T. Kubota M. Omura K. Matsuo I. Mizushima K. Okano H. Kawasaki S. Inaba T. Izumida T. Kanemura N. Aoki K. Ishimaru H. Ishiuchi K. Suguro K. Eguchi Y. Tsunashima Sidewall transfer process and selective gate sidewall spacer formation technology for sub-15nm FinFET with elevated source/drain extension IEEE International Electron Devices Meeting 2005. IEDM Technical Digest Washington DC 5 December 2005 (IEEE 2005).

Cited by

Metadata

Authors
Johannes, A., Salomon, D., Martinez-Criado, G., Glaser, M., Lugstein, A., & Ronning, C.
Affiliations
  • European Synchrotron Radiation Facility (FR)
  • European Synchrotron Radiation Facility, 71 Avenue des Martyrs, Grenoble 30843, France.
  • TU Wien (AT)
  • Friedrich Schiller University Jena (DE)
Corresponding author
Johannes, Andreas
Venue
Science Advances
Published
2017-12
Volume
3
Issue
12
Pages
eaao4044-eaao4044
ISSN
2375-2548 (ISSN-L)
OpenAlex
W2775279603
Cited by
49
References
41
Citations by year
2026: 1 · 2025: 3 · 2024: 1 · 2023: 1 · 2022: 7 · 2021: 3 · 2020: 6 · 2019: 22 · 2018: 5
FWCI
8.51
Type
journal article
Language
en
Open access
Licence
cc-by-nc
Locations
  • Science Advances (publishedVersion, cc-by-nc)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • DIGITAL.CSIC (Spanish National Research Council (CSIC)) (submittedVersion, cc-by-nc)
Funders
  • Deutsche Forschungsgemeinschaft (award339734, RO 1198/14-1)
  • European Synchrotron Radiation Facility (award339741)
  • Bundesministerium für Bildung und Forschung (award339739, 05K16SJ1)
  • Austrian Science Fund (award339735, No. I 724-N16)
Topics
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced X-ray Imaging Techniques
  • Physical Sciences › Physics and Astronomy › Radiation › X-ray Spectroscopy and Fluorescence Analysis
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Electron and X-Ray Spectroscopy Techniques
Keywords
depletion region, semiconductor heterostructures, semiconductor nanowires, chemical speciation, built-in electric field, energy band diagram, current-voltage characteristics, strain gradient, epitaxial heterostructures

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.