The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
High-resolution non-destructive three-dimensional imaging of integrated circuits
Open accessAbstract
Modern nanoelectronics has advanced to a point at which it is impossible to image entire devices and their interconnections non-destructively because of their small feature sizes and the complex three-dimensional structures resulting from their integration on a chip. This metrology gap implies a lack of direct feedback between design and manufacturing processes, and hampers quality control during production, shipment and use. Here we demonstrate that X-ray ptychography—a high-resolution coherent diffractive imaging technique—can create three-dimensional images of integrated circuits of known and unknown designs with a lateral resolution in all directions down to 14.6 nanometres. We obtained detailed device geometries and corresponding elemental maps, and show how the devices are integrated with each other to form the chip. Our experiments represent a major advance in chip inspection and reverse engineering over the traditional destructive electron microscopy and ion milling techniques. Foreseeable developments in X-ray sources, optics and detectors, as well as adoption of an instrument geometry optimized for planar rather than cylindrical samples, could lead to a thousand-fold increase in efficiency, with concomitant reductions in scan times and voxel sizes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physics of Semiconductor Devices
Sze, S. M., & Ng, K. K. (2006) · doi:10.1002/0470068329 · Cited by 14,627
CMOS: Circuit Design, Layout, and Simulation
Baker, R. J. (2010) · doi:10.1002/9780470891179 · Cited by 709
Cited by
Zeng, M., Xiao, Y., Liu, J., Yang, K., & Fu, L. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00633 · Cited by 574
Further improvements to the ptychographical iterative engine
Maiden, A., Johnson, D., & Li, P. (2017) · Optica · doi:10.1364/optica.4.000736 · Cited by 452
In operando x-ray imaging of nanoscale devices: Composition, valence, and internal electrical fields
Johannes, A., Salomon, D., Martinez-Criado, G., Glaser, M., Lugstein, A., & Ronning, C. (2017) · Science Advances · doi:10.1126/sciadv.aao4044 · Cited by 49
Probing Organic Thin Films by Coherent X-ray Imaging and X-ray Scattering
Patil, N., Narayanan, T., Michels, L., Skjønsfjell, E. T. B., Guizar-Sicairos, M., Van den Brande, N., Claessens, R., Van Mele, B., & Breiby, D. W. (2019) · ACS Applied Polymer Materials · doi:10.1021/acsapm.9b00324 · Cited by 6
Self-citation
Metadata
- Authors
- Holler, M., Guizar-Sicairos, M., Tsai, E. H. R., Dinapoli, R., Müller, E., Bunk, O., Raabe, J., & Aeppli, G.
- Venue
- Nature
- Published
- 2017-03
- Volume
- 543
- Issue
- 7645
- Pages
- 402-406
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2595276417
- Cited by
- 497
- References
- 2
- FWCI
- 50.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-resolution non-destructive three-dimensional imaging of integrated circuits. https://app.cochat.ai/papers/10.1038/nature21698
- The paper
- Holler, M., Guizar-Sicairos, M., Tsai, E. H. R., Dinapoli, R., Müller, E., Bunk, O., Raabe, J., & Aeppli, G. (2017). High-resolution non-destructive three-dimensional imaging of integrated circuits. Nature. https://doi.org/10.1038/nature21698
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.