Optimal control pulses for the 1.2-GHz (28.2-T) NMR spectrometers
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The ability to measure nuclear magnetic resonance (NMR) spectra with a large sample volume is crucial for concentration-limited biological samples to attain adequate signal-to-noise (S/N) ratio. The possibility to measure with a 5-mm cryoprobe is currently absent at the 1.2-GHz NMR instruments due to the exceedingly high radio frequency power demands, which is four times compared to 600-MHz instruments. Here, we overcome the high-power demands by designing optimal control (OC) pulses with up to 20 times lower power requirements than currently necessary at a 1.2-GHz spectrometer. We show that multidimensional biomolecular NMR experiments constructed using these OC pulses can bestow improvement in the S/N ratio of up to 26%. With the expected power limitations of a 5-mm cryoprobe, we observe an enhancement in the S/N ratio of more than 240% using our OC sequences. This motivates the development of a cryoprobe with a larger volume than the current 3-mm cryoprobes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“More recently, OTC-designed pulses have been employed in triple-resonance experiments to achieve broader band widths [13,14] and minimize the power deposition in cryoprobes for ultra-high magnetic fields ( i.e. , 1.2 GHz). [15]”
From Artificial Intelligence-Designed Ultra-Low-Power Broadband Universal and Pulses for NMR Spectroscopy: Application to 19F NMR (2026) · cites this paper as [15]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Enhancement of nuclear magnetic resonance signals by polarization transfer
Morris, G. A., & Freeman, R. (1979) · Journal of the American Chemical Society · doi:10.1021/ja00497a058 · Cited by 2,015
Khaneja, N., Reiss, T., Kehlet, C., Schulte-Herbrüggen, T., & Glaser, S. J. (2005) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2004.11.004 · Cited by 1,854 · cited 1×
“OC theory was introduced to NMR spectroscopy two decades ago as gradient ascent pulse engineering (GRAPE) ( 37 , 38 ) algorithm, which is a general method for pulse design.”
MethodPrinciples of Nuclear Magnetic Resonance in One and Two Dimensions
Ernst, R. R., Bodenhausen, G., & Wokaun, A. (1990) · doi:10.1093/oso/9780198556473.001.0001 · Cited by 1,418
Recognition Dynamics Up to Microseconds Revealed from an RDC-Derived Ubiquitin Ensemble in Solution
Lange, O. F., Lakomek, N.-A., Farès, C., Schröder, G. F., Walter, K. F. A., Becker, S., Meiler, J., Grubmüller, H., Griesinger, C., & de Groot, B. L. (2008) · Science · doi:10.1126/science.1157092 · Cited by 1,044
Self-citationBand-selective radiofrequency pulses
Geen, H., & Freeman, R. (1991) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(91)90034-q · Cited by 828
Quantitative dynamics and binding studies of the 20S proteasome by NMR
Sprangers, R., & Kay, L. E. (2007) · Nature · doi:10.1038/nature05512 · Cited by 527
Facing and Overcoming Sensitivity Challenges in Biomolecular NMR Spectroscopy
Ardenkjaer‐Larsen, J., Boebinger, G. S., Comment, A., Duckett, S., Edison, A. S., Engelke, F., Griesinger, C., Griffin, R. G., Hilty, C., Maeda, H., et al. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201410653 · Cited by 351
Self-citationEmsley, L., & Bodenhausen, G. (1990) · Chemical Physics Letters · doi:10.1016/0009-2614(90)87025-m · Cited by 345
Skinner, T. E., Reiss, T. O., Luy, B., Khaneja, N., & Glaser, S. J. (2003) · Journal of Magnetic Resonance · doi:10.1016/s1090-7807(03)00153-8 · Cited by 298
Shaped radiofrequency pulses in high resolution NMR
Freeman, R. (1998) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/s0079-6565(97)00024-1 · Cited by 174
Research works printed but not linked: 68
- A. Abragam The Principles of Nuclear Magnetism (Oxford Univ. Press 1983) 618 pp.
- J. Cavanagh N. Skelton W. Fairbrother M. Rance A. Palmer III Protein NMR Spectroscopy Principles and Practice (Elsevier Academic Press ed. 2 2007).
- 10.1021/ja502705y · DOI
- 10.1016/j.pnmrs.2014.05.003 · DOI · Paper page
- 10.1038/s41467-022-31374-5 · DOI
- 10.1016/S0021-9258(18)45665-7 · DOI · Paper page
- 10.1073/pnas.0610313104 · DOI · Paper page
- 10.1021/ar200137d · DOI
- 10.1038/s41467-020-19371-y · DOI
- 10.1073/pnas.2004317117 · DOI
- 10.1126/science.8332909 · DOI · Paper page
- 10.1021/acs.chemrev.1c00937 · DOI
- 10.1002/anie.201304272 · DOI
- 10.1002/mrc.5106 · DOI
- 10.1088/1361-6668/ac4951 · DOI
- 10.1002/anie.201705936 · DOI
- 10.3390/biom11050752 · DOI
- 10.1007/s10858-021-00373-x · DOI
- 10.1007/s10858-021-00358-w · DOI
- 10.1002/anie.201800220 · DOI
- 10.1021/ja993743x · DOI
- 10.1007/s00216-006-0982-4 · doi:10.1007/s00216-006-0982-4
- 10.1063/1.1718815 · DOI
- 10.1002/cmr.a.21221 · doi:10.1002/cmr.a.21221
- 10.1016/j.jmr.2006.08.002 · DOI
- 10.1126/science.280.5362.421 · DOI · Paper page
- N. Khaneja “Geometric control in classical and quantum systems ” thesis Harvard University Cambridge MA (2000).
- N. Khaneja S. Glaser R. Brockett Subriemannian geodesics and optimal control of spin systems in Proceedings of the 2002 American Control Conference (IEEE 2002) vol. 4 pp. 2806–2811. · doi:10.1109/acc.2002.1025214
- 10.1103/PhysRevA.65.032301 · DOI · Paper page
- 10.1103/PhysRevA.63.032308 · DOI · Paper page
- 10.1006/jmre.2001.2480 · DOI
- N. C. Nielsen C. Kehlet S. J. Glaser N. Khaneja Optimal control methods in NMR spectroscopy. eMagRes (2010). · DOI
- 10.1016/j.jmr.2008.11.020 · DOI · Paper page
- I. Kuprov Optimal control of spin systems in Spin: From Basic Symmetries to Quantum Optimal Control (Springer International Publishing 2023) pp. 313–349. · doi:10.1007/978-3-031-05607-9_8
- 10.1016/j.jmr.2004.06.017 · DOI · Paper page
- 10.1016/j.jmr.2008.05.023 · DOI
- 10.1016/j.jmr.2012.09.013 · DOI · Paper page
- 10.1016/j.jmr.2003.12.001 · DOI
- 10.1016/j.jmr.2005.12.010 · DOI
- 10.1016/j.jmr.2010.11.008 · DOI · Paper page
- 10.1063/1.4949534 · DOI
- 10.1063/1.4928978 · DOI
- 10.1016/j.jmr.2011.07.023 · DOI · Paper page
- 10.1016/j.jmr.2013.04.007 · DOI
- 10.1016/j.jmr.2012.12.007 · DOI · Paper page
- 10.1016/j.jmr.2014.12.016 · DOI
- 10.1002/anie.202002463 · DOI · Paper page
- 10.1038/s41467-018-05400-4 · DOI
- 10.1002/anie.201400178 · DOI
- 10.1016/j.jmr.2012.02.007 · DOI
- 10.1007/s10858-022-00404-1 · DOI · Paper page
- 10.1016/j.jmr.2007.06.011 · DOI
- 10.1021/ja054035g · DOI
- 10.1126/sciadv.abj5913 · DOI
- 10.1021/jacs.2c06568 · DOI
- 10.1103/PhysRevA.98.023625 · DOI
- 10.1088/1361-6455/ab6df6 · DOI
- 10.1103/PhysRevA.101.063625 · DOI
- 10.1016/S0079-6565(98)00025-9 · DOI · Paper page
- L. Emsley, G. Bodenhausen, Optimization of shaped selective pulses for NMR using a quaternion description of their overall propagators. J. Magn. Reson. 97, 135–148 (1992).
- D. L. Goodwin “Advanced optimal control methods for spin systems ” thesis University of Southampton Southampton UK (2017).
- 10.1016/j.jmr.2013.02.012 · DOI
- 10.1016/S1090-7807(02)00194-5 · DOI
- 10.1016/S1090-7807(03)00003-X · DOI
- 10.1007/s10858-005-3592-0 · DOI
- 10.1016/j.jmr.2021.106928 · DOI
- 10.1016/j.jmr.2017.05.011 · DOI · Paper page
- 10.1007/s10858-017-0141-6 · DOI
Cited by
Manu, V. S., Barany, G., & Veglia, G. (2026) · doi:10.2139/ssrn.6626947
Metadata
- Authors
- Joseph, D., & Griesinger, C.
- Affiliations
- Max Planck Institute for Multidisciplinary Sciences, Göttingen, Niedersachsen D-37077, Germany.
- Venue
- Science Advances
- Published
- 2023-11-10
- Volume
- 9
- Issue
- 45
- ISSN
- 2375-2548
- Cited by
- 31
- References
- 10
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.