The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Femtotesla Magnetic Field Measurement with Magnetoresistive Sensors
Abstract
The measurement of magnetic fields in the femtotesla (fT, 10 –15 tesla) range is important for applications such as magnetometry, quantum computing, solid-state nuclear magnetic resonance, and magnetoencephalography. The only sensors capable of detecting these very small fields have been based on low-temperature superconducting quantum interference devices operating at 4.2 kelvin. We present a magnetic field sensor that combines a superconducting flux-to-field transformer with a low-noise giant magnetoresistive sensor. The sensor can be operated up to 77 kelvin. Our small-size prototype provides the capability of measuring 32 fT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Large Magnetoresistance at Room Temperature in Ferromagnetic Thin Film Tunnel Junctions
Moodera, J. S., Kinder, L. R., Wong, T. M., & Meservey, R. (1995) · Physical Review Letters · doi:10.1103/physrevlett.74.3273 · Cited by 3,707
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Functional neuroimaging of speech perception in infants
Dehaene-Lambertz, G., Dehaene, S., & Hertz-Pannier, L. (2002) · Science · doi:10.1126/science.1077066 · Cited by 1,113
Dynamics of brain activation during picture naming
Salmelin, R., Hari, R., Lounasmaa, O. V., & Sams, M. (1994) · Nature · doi:10.1038/368463a0 · Cited by 381
SQUID Sensors: Fundamentals, Fabrication and Applications
(1996) · doi:10.1007/978-94-011-5674-5 · Cited by 367
Drung, D., Cantor, R., Peters, M., Scheer, H. J., & Koch, H. (1990) · Applied Physics Letters · doi:10.1063/1.103650 · Cited by 223
DC-SQUID electronics based on adaptive positive feedback: experiments
Seppä, H., Ahonen, A., Knuutila, J., et al. (1991) · IEEE Transactions on Magnetics · doi:10.1109/20.133723 · Cited by 42
Cited by
Magnetic sensors and their applications
Lenz, J., & Edelstein, S. (2006) · IEEE Sensors Journal · doi:10.1109/jsen.2006.874493 · Cited by 1,312
Applications of the signal space separation method
Taulu, S., Simola, J., & Kajola, M. (2005) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2005.853302 · Cited by 548
Self-citationFreitas, P. P., Ferreira, R., Cardoso, S., & Cardoso, F. (2007) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/19/16/165221 · Cited by 422
Topological effects in nanomagnetism: from superparamagnetism to chiral quantum solitons
Braun, H.-B. (2012) · Advances in Physics · doi:10.1080/00018732.2012.663070 · Cited by 421
Presentation of electromagnetic multichannel data: The signal space separation method
Taulu, S., & Kajola, M. (2005) · Journal of Applied Physics · doi:10.1063/1.1935742 · Cited by 390
Metadata
- Authors
- Pannetier, M., Fermon, C., Le Goff, G., Simola, J., & Kerr, E.
- Venue
- Science
- Published
- 2004-06-11
- Volume
- 304
- Issue
- 5677
- Pages
- 1648-1650
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1993244266
- Cited by
- 314
- References
- 7
- FWCI
- 8.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Femtotesla Magnetic Field Measurement with Magnetoresistive Sensors. https://app.cochat.ai/papers/10.1126/science.1096841
- The paper
- Pannetier, M., Fermon, C., Le Goff, G., Simola, J., & Kerr, E. (2004). Femtotesla Magnetic Field Measurement with Magnetoresistive Sensors. Science. https://doi.org/10.1126/science.1096841
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.