The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Near-Field Microscopy Through a SiC Superlens
Abstract
The wave nature of light limits the spatial resolution in classical microscopy to about half of the illumination wavelength. Recently, a new approach capable of achieving subwavelength spatial resolution, called superlensing, was invented, challenging the already established method of scanning near-field optical microscopy (SNOM). We combine the advantages of both techniques and demonstrate a novel imaging system where the objects no longer need to be in close proxim-ity to a near-field probe, allowing for optical near-field microscopy of subsurface objects at sub-wavelength-scale lateral resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Negative Refraction Makes a Perfect Lens
Pendry, J. B. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.3966 · Cited by 12,159
Metamaterials and Negative Refractive Index
Smith, D. R., Pendry, J. B., & Wiltshire, M. C. K. (2004) · Science · doi:10.1126/science.1096796 · Cited by 4,541
Sub-Diffraction-Limited Optical Imaging with a Silver Superlens
Fang, N., Lee, H., Sun, C., & Zhang, X. (2005) · Science · doi:10.1126/science.1108759 · Cited by 3,968
Phonon-enhanced light–matter interaction at the nanometre scale
Hillenbrand, R., Taubner, T., & Keilmann, F. (2002) · Nature · doi:10.1038/nature00899 · Cited by 844
Self-citationScanning Interferometric Apertureless Microscopy: Optical Imaging at 10 Angstrom Resolution
Zenhausern, F., Martin, Y., & Wickramasinghe, H. K. (1995) · Science · doi:10.1126/science.269.5227.1083 · Cited by 692
Super-resolution imaging through a planar silver layer
Melville, D. O. S., & Blaikie, R. J. (2005) · Optics Express · doi:10.1364/opex.13.002127 · Cited by 471
Near-field optics: from subwavelength illumination to nanometric shadowing
Lewis, A., Taha, H., Strinkovski, A., Manevitch, A., Khatchatouriants, A., Dekhter, R., & Ammann, E. (2003) · Nature Biotechnology · doi:10.1038/nbt898 · Cited by 170
Cited by
Optical negative-index metamaterials
Shalaev, V. M. (2007) · Nature Photonics · doi:10.1038/nphoton.2006.49 · Cited by 2,801
Far-Field Optical Hyperlens Magnifying Sub-Diffraction-Limited Objects
Liu, Z., Lee, H., Xiong, Y., Sun, C., & Zhang, X. (2007) · Science · doi:10.1126/science.1137368 · Cited by 2,177
Searching for better plasmonic materials
West, P. R., Ishii, S., Naik, G. V., Emani, N. K., Shalaev, V. M., & Boltasseva, A. (2010) · Laser & Photonics Reviews · doi:10.1002/lpor.200900055 · Cited by 2,116
Low-Loss Plasmonic Metamaterials
Boltasseva, A., & Atwater, H. A. (2011) · Science · doi:10.1126/science.1198258 · Cited by 1,543
Theory of surface plasmons and surface-plasmon polaritons
Pitarke, J. M., Silkin, V. M., Chulkov, E. V., & Echenique, P. M. (2007) · Reports on Progress in Physics · doi:10.1088/0034-4885/70/1/r01 · Cited by 1,524
Metadata
- Authors
- Taubner, T., Korobkin, D., Urzhumov, Y., Shvets, G., & Hillenbrand, R.
- Venue
- Science
- Published
- 2006-09-15
- Volume
- 313
- Issue
- 5793
- Pages
- 1595-1595
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2075448644
- Cited by
- 597
- References
- 7
- FWCI
- 25.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.