The DOI matches its Crossref record; 31 of the 32 references it cites were found in a registry or an index, and 1 are not checked yet.
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Open accessAbstract
Time has always had a special status in physics because of its fundamental role in specifying the regularities of nature and because of the extraordinary precision with which it can be measured. This precision enables tests of fundamental physics and cosmology, as well as practical applications such as satellite navigation. Recently, a regime of operation for atomic clocks based on optical transitions has become possible, promising even higher performance. We report the frequency ratio of two optical atomic clocks with a fractional uncertainty of 5.2 × 10–17. The ratio of aluminum and mercury single-ion optical clock frequencies ν Al+/ν Hg+is 1.052871833148990438(55), where the uncertainty comprises a statistical measurement uncertainty of 4.3 × 10–17, and systematic uncertainties of 1.9 × 10–17 and 2.3 × 10–17 in the mercury and aluminum frequency standards, respectively. Repeated measurements during the past year yield a preliminary constraint on the temporal variation of the fine-structure constant α of\batchmode \documentclass[fleqn,10pt,legalpaper]{article} \usepackage{amssymb} \usepackage{amsfonts} \usepackage{amsmath} \pagestyle{empty} \begin{document} \({\dot{{\alpha}}}{/}{\alpha}=(-1.6{\pm}2.3){\times}10^{-17}{/}\mathrm{year}\) \end{document}.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“Atomic clock experiments constrain the current variation of the fine structure constant, | α/α 0 | < 10 -17 yr -1 [13]”
From Stress-energy tensor of a scalar field on a product spacetime with a time-dependent compact dimension (2026) · cites this paper as [13]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredIn the citing paper
“d dt ln m Hg m Al ¼ ð5:3 Æ 7:9Þ Â 10 À17 yr À1 :ð131Þ”
From Fundamental constants: from measurement to the universe, a window on gravitation and cosmology (2025) · cites this paper as Rosenband et al. 2008
In the citing paper
“_ a EM =a EM ¼ ðÀ1:6 Æ 2:3Þ Â 10 À17 yr À1 on a EM alone”
From Fundamental constants: from measurement to the universe, a window on gravitation and cosmology (2025) · cites this paper as Rosenband et al. 2008
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Effect of Collisions upon the Doppler Width of Spectral Lines
Dicke, R. H. (1953) · Physical Review · doi:10.1103/physrev.89.472 · Cited by 1,491
Nobel Lecture: Passion for precision
Hänsch, T. W. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1297 · Cited by 913
Minimization of ion micromotion in a Paul trap
Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1998) · Journal of Applied Physics · doi:10.1063/1.367318 · Cited by 720
Self-citationAn Optical Clock Based on a Single Trapped 199 Hg + Ion
Diddams, S. A., Udem, T., Bergquist, J., Curtis, E. A., Drullinger, R. E., Hollberg, L. W., Itano, W. M., Lee, W. D., Oates, C. W., Vogel, K. R., et al. (2001) · Science · doi:10.1126/science.1061171 · Cited by 720
Self-citationSpectroscopy Using Quantum Logic
Schmidt, P. O., Rosenband, T., Langer, C., Itano, W. M., Bergquist, J. C., & Wineland, D. J. (2005) · Science · doi:10.1126/science.1114375 · Cited by 643
Self-citationNobel Lecture: Defining and measuring optical frequencies
Hall, J. L. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1279 · Cited by 630
Visible Lasers with Subhertz Linewidths
Young, B. C., Cruz, F. C., Itano, W. M., & Bergquist, J. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.3799 · Cited by 605
Self-citationUltrastable Optical Clock with Neutral Atoms in an Engineered Light Shift Trap
Katori, H., Takamoto, M., Pal’chikov, V. G., & Ovsiannikov, V. D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.173005 · Cited by 580
Heating of trapped ions from the quantum ground state
Turchette, Q. A., Kielpinski, D., King, B. E., Leibfried, D. G., Meekhof, D. M., Myatt, C. J., Rowe, M. A., Sackett, C. A., Wood, C. S., Itano, W. M., et al. (2000) · Physical Review A · doi:10.1103/physreva.61.063418 · Cited by 532
Self-citationMonoion oscillator as potential ultimate laser frequency standard
DEHMELT, H. G. (1982) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.1982.6312526 · Cited by 326
Optical Frequency Synthesis and Comparison with Uncertainty at the 10 -19 Level
Ma, L.-S., Bi, Z., Bartels, A., Robertsson, L., Zucco, M., Windeler, R. S., Wilpers, G., Oates, C., Hollberg, L., & Diddams, S. A. (2004) · Science · doi:10.1126/science.1095092 · Cited by 319
Self-citationSingle-Atom Optical Clock with High Accuracy
Oskay, W. H., Diddams, S. A., Donley, E. A., Fortier, T. M., Heavner, T. P., Hollberg, L. W., Itano, W. M., Jefferts, S. R., Delaney, M. J., Kim, K., et al. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.020801 · Cited by 298
Self-citationDzuba, V. A., Flambaum, V. V., & Webb, J. K. (1999) · Physical Review A · doi:10.1103/physreva.59.230 · Cited by 294
Scaling and Suppression of Anomalous Heating in Ion Traps
Deslauriers, L., Olmschenk, S., Stick, D., Hensinger, W. K., Sterk, J. D., & Monroe, C. R. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.103007 · Cited by 291
Laser stabilization at the millihertz level
Salomon, C., Hils, D., & Hall, J. L. (1988) · Journal of the Optical Society of America B · doi:10.1364/josab.5.001576 · Cited by 246
Observation of the S01→P03 Clock Transition in Al+27
Rosenband, T., Schmidt, P. O., Hume, D. B., Itano, W. M., Fortier, T. M., Stalnaker, J. E., Kim, K., Diddams, S. A., Koelemeij, J. C. J., Bergquist, J., et al. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.220801 · Cited by 226
Self-citationFortier, T. M., Ashby, N., Bergquist, J. C., Delaney, M. J., Diddams, S. A., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Kim, K., et al. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.070801 · Cited by 226
Self-citationExternal-field shifts of the 199-Hg(+) optical frequency standard
Itano, W. M. (2000) · Journal of Research of the National Institute of Standards and Technology · doi:10.6028/jres.105.065 · Cited by 221
Self-citationFortier, T. M., Bartels, A., & Diddams, S. A. (2006) · Optics Letters · doi:10.1364/ol.31.001011 · Cited by 213
Self-citationSympathetic cooling of 9Be+ and 24Mg+ for quantum logic
Barrett, M. D., DeMarco, B., Schaetz, T., Meyer, V., Leibfried, D. G., Britton, J., Chiaverini, J., Itano, W. M., Jelenkovic, B. M., Jost, J. D., et al. (2003) · Physical Review A · doi:10.1103/physreva.68.042302 · Cited by 192
Self-citationRecoilless optical absorption and Doppler sidebands of a single trapped ion
Bergquist, J., Itano, W. M., & Wineland, D. J. (1987) · Physical Review A · doi:10.1103/physreva.36.428 · Cited by 187
Self-citationHigh-Fidelity Adaptive Qubit Detection through Repetitive Quantum Nondemolition Measurements
Hume, D. B., Rosenband, T., & Wineland, D. J. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.120502 · Cited by 182
Self-citationLaser-cooling limits and single-ion spectroscopy
Wineland, D. J., Itano, W. M., Bergquist, J., & Hulet, R. G. (1987) · Physical Review A · doi:10.1103/physreva.36.2220 · Cited by 165
Self-citationCoddington, I. R., Swann, W. C., Lorini, L., Bergquist, J., Coq, Y. L., Oates, C. W., Quraishi, Q. S., Feder, K. S., Nicholson, J. W., Westbrook, P. S., et al. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.71 · Cited by 118
Self-citationFiber-laser frequency combs with subhertz relative linewidths
Swann, W. C., McFerran, J. J., Coddington, I. R., Newbury, N. R., Hartl, I., Fermann, M. E., Westbrook, P. S., Nicholson, J. W., Feder, K. S., Langrock, C., et al. (2006) · Optics Letters · doi:10.1364/ol.31.003046 · Cited by 115
Self-citationAn optical lattice clock with spin-polarized 87Sr atoms
Baillard, X., Fouché, M., Targat, R. L., Westergaard, P. G., Lecallier, A., Chapelet, F., Abgrall, M., Rovera, D., Laurent, P., Rosenbusch, P., et al. (2007) · The European Physical Journal D · doi:10.1140/epjd/e2007-00330-3 · Cited by 112
Angstmann, E., Dzuba, V. A., & Flambaum, V. V. (2004) · Physical Review A · doi:10.1103/physreva.70.014102 · Cited by 108
A laser frequency lock referenced to a single trapped ion
Bernard, J. E., Marmet, L., & Madej, A. A. (1998) · Optics Communications · doi:10.1016/s0030-4018(98)00121-7 · Cited by 91
Oskay, W. H., Itano, W. M., & Bergquist, J. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.163001 · Cited by 74
Self-citationThe relativistic redshift with 3 10 17uncertainty at NIST, Boulder, Colorado, USA
Pavlis, N. K., & Weiss, M. A. (2003) · Metrologia · doi:10.1088/0026-1394/40/2/311 · Cited by 57
Optical-to-microwave frequency comparison with fractional uncertainty of 10-15
Stalnaker, J. E., Diddams, S. A., Fortier, T. M., Kim, K., Hollberg, L. W., Bergquist, J., Itano, W. M., Delany, M. J., Lorini, L., Oskay, W. H., et al. (2007) · Applied Physics B · doi:10.1007/s00340-007-2762-z · Cited by 55
Self-citationNIST cesium fountains: current status and future prospects
Jefferts, S. R., Heavner, T. P., Parker, T. E., & Shirley, J. H. (2007) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.734965 · Cited by 21
Flagged first, then by citations
Cited by
Sorted by citations
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Quantum information with Rydberg atoms
Saffman, M. E., Walker, T. G., & Mølmer, K. (2010) · Reviews of Modern Physics · doi:10.1103/revmodphys.82.2313 · Cited by 2,904
“the similar approach applied in ion traps (Rosenband et al., 2008)).”
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Self-citationMicroresonator-Based Optical Frequency Combs
Kippenberg, T. J., Holzwarth, R., & Diddams, S. A. (2011) · Science · doi:10.1126/science.1193968 · Cited by 2,159
Self-citationNanoscale magnetic sensing with an individual electronic spin in diamond
Maze, J. R., Stanwix, P. L., Hodges, J. S., Hong, S., Taylor, J. M., Cappellaro, P., Jiang, L., Dutt, M. V. G., Togan, E., Zibrov, A. S., et al. (2008) · Nature · doi:10.1038/nature07279 · Cited by 2,010
Metadata
- Authors
- Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., Diddams, S. A., Swann, W. C., Newbury, N. R., Itano, W. M., Wineland, D. J., & Bergquist, J. C.
- Affiliations
- National Institute of Standards and Technology (US)
- Corresponding author
- Rosenband, T.
- Schmidt, P. O.
- Lorini, L.
- Oskay, W. H.
- Stalnaker, J. E.
- ORCID
- Venue
- Science
- Published
- 2008-03-28
- Volume
- 319
- Issue
- 5871
- Pages
- 1808-1812
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1997269293
- Cited by
- 1,450
- References
- 31
- Citations by year
- 2026: 27 · 2025: 62 · 2024: 52 · 2023: 44 · 2022: 43 · 2021: 50 · 2020: 60 · 2019: 78 · 2018: 65 · 2017: 76 · 2016: 85 · 2015: 96 · 2014: 129 · 2013: 99 · 2012: 99
- FWCI
- 73.95
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Science (publishedVersion)
- PubMed (publishedVersion)
- CINECA IRIS Institutional Research Information System (IRIS Istituto Nazionale di Ricerca Metrologica) (submittedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Keywords
- optical atomic clocks, aluminum ions, mercury ions, frequency ratio, frequency metrology, fine-structure constant variation, systematic uncertainties
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review