The DOI matches its Crossref record; 31 of the 32 references it cites were found in a registry or an index, and 1 are not checked yet.
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Open accessAbstract
Time has always had a special status in physics because of its fundamental role in specifying the regularities of nature and because of the extraordinary precision with which it can be measured. This precision enables tests of fundamental physics and cosmology, as well as practical applications such as satellite navigation. Recently, a regime of operation for atomic clocks based on optical transitions has become possible, promising even higher performance. We report the frequency ratio of two optical atomic clocks with a fractional uncertainty of 5.2 × 10–17. The ratio of aluminum and mercury single-ion optical clock frequencies ν Al+/ν Hg+is 1.052871833148990438(55), where the uncertainty comprises a statistical measurement uncertainty of 4.3 × 10–17, and systematic uncertainties of 1.9 × 10–17 and 2.3 × 10–17 in the mercury and aluminum frequency standards, respectively. Repeated measurements during the past year yield a preliminary constraint on the temporal variation of the fine-structure constant α of\batchmode \documentclass[fleqn,10pt,legalpaper]{article} \usepackage{amssymb} \usepackage{amsfonts} \usepackage{amsmath} \pagestyle{empty} \begin{document} \({\dot{{\alpha}}}{/}{\alpha}=(-1.6{\pm}2.3){\times}10^{-17}{/}\mathrm{year}\) \end{document}.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“Atomic clock experiments constrain the current variation of the fine structure constant, | α/α 0 | < 10 -17 yr -1 [13]”
From Stress-energy tensor of a scalar field on a product spacetime with a time-dependent compact dimension (2026) · cites this paper as [13]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredIn the citing paper
“d dt ln m Hg m Al ¼ ð5:3 Æ 7:9Þ Â 10 À17 yr À1 :ð131Þ”
From Fundamental constants: from measurement to the universe, a window on gravitation and cosmology (2025) · cites this paper as Rosenband et al. 2008
In the citing paper
“_ a EM =a EM ¼ ðÀ1:6 Æ 2:3Þ Â 10 À17 yr À1 on a EM alone”
From Fundamental constants: from measurement to the universe, a window on gravitation and cosmology (2025) · cites this paper as Rosenband et al. 2008
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Effect of Collisions upon the Doppler Width of Spectral Lines
Dicke, R. H. (1953) · Physical Review · doi:10.1103/physrev.89.472 · Cited by 1,491
Nobel Lecture: Passion for precision
Hänsch, T. W. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1297 · Cited by 913
Minimization of ion micromotion in a Paul trap
Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1998) · Journal of Applied Physics · doi:10.1063/1.367318 · Cited by 720
Self-citationAn Optical Clock Based on a Single Trapped 199 Hg + Ion
Diddams, S. A., Udem, T., Bergquist, J., Curtis, E. A., Drullinger, R. E., Hollberg, L. W., Itano, W. M., Lee, W. D., Oates, C. W., Vogel, K. R., et al. (2001) · Science · doi:10.1126/science.1061171 · Cited by 720
Self-citationSpectroscopy Using Quantum Logic
Schmidt, P. O., Rosenband, T., Langer, C., Itano, W. M., Bergquist, J. C., & Wineland, D. J. (2005) · Science · doi:10.1126/science.1114375 · Cited by 643
Self-citationNobel Lecture: Defining and measuring optical frequencies
Hall, J. L. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1279 · Cited by 630
Visible Lasers with Subhertz Linewidths
Young, B. C., Cruz, F. C., Itano, W. M., & Bergquist, J. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.3799 · Cited by 605
Self-citationUltrastable Optical Clock with Neutral Atoms in an Engineered Light Shift Trap
Katori, H., Takamoto, M., Pal’chikov, V. G., & Ovsiannikov, V. D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.173005 · Cited by 580
Heating of trapped ions from the quantum ground state
Turchette, Q. A., Kielpinski, D., King, B. E., Leibfried, D. G., Meekhof, D. M., Myatt, C. J., Rowe, M. A., Sackett, C. A., Wood, C. S., Itano, W. M., et al. (2000) · Physical Review A · doi:10.1103/physreva.61.063418 · Cited by 532
Self-citationMonoion oscillator as potential ultimate laser frequency standard
DEHMELT, H. G. (1982) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.1982.6312526 · Cited by 326
Flagged first, then by citations
Cited by
Sorted by citations
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Quantum information with Rydberg atoms
Saffman, M. E., Walker, T. G., & Mølmer, K. (2010) · Reviews of Modern Physics · doi:10.1103/revmodphys.82.2313 · Cited by 2,904
“the similar approach applied in ion traps (Rosenband et al., 2008)).”
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Self-citationMicroresonator-Based Optical Frequency Combs
Kippenberg, T. J., Holzwarth, R., & Diddams, S. A. (2011) · Science · doi:10.1126/science.1193968 · Cited by 2,159
Self-citationNanoscale magnetic sensing with an individual electronic spin in diamond
Maze, J. R., Stanwix, P. L., Hodges, J. S., Hong, S., Taylor, J. M., Cappellaro, P., Jiang, L., Dutt, M. V. G., Togan, E., Zibrov, A. S., et al. (2008) · Nature · doi:10.1038/nature07279 · Cited by 2,010
Search for new physics with atoms and molecules
Safronova, M. S., Budker, D., DeMille, D. P., Kimball, D. F. J., Derevianko, A., & Clark, C. W. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.025008 · Cited by 1,642
Cold and ultracold molecules: science, technology and applications
Carr, L. D., DeMille, D. P., Krems, R. V., & Ye, J. (2009) · New Journal of Physics · doi:10.1088/1367-2630/11/5/055049 · Cited by 1,357
“State-of-the-art optical atomic clocks have set the most stringent limits on both types of α variations [176, 183], but atoms generally lack transitions that can reveal relative μ variations (∆μ/μ) in a model-independent way.”
BackgroundEntangled states of trapped atomic ions
Blatt, R., & Wineland, D. J. (2008) · Nature · doi:10.1038/nature07125 · Cited by 1,214
“In addition to this demonstration, this protocol is now used in a high-accuracy optical clock based on single 27 Al p ion”
Self-citationAn optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Rapid and precise absolute distance measurements at long range
Coddington, I., Swann, W. C., Nenadovic, L., & Newbury, N. R. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.94 · Cited by 1,059
Self-citation20 years of developments in optical frequency comb technology and applications
Fortier, T., & Baumann, E. (2019) · Communications Physics · doi:10.1038/s42005-019-0249-y · Cited by 995
Self-citationBritton, J. W., Sawyer, B. C., Keith, A. C., Wang, C.-C. J., Freericks, J. K., Uys, H., Biercuk, M. J., & Bollinger, J. J. (2012) · Nature · doi:10.1038/nature10981 · Cited by 941
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Self-citationAn Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817
Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
Self-citationVarying Constants, Gravitation and Cosmology
Uzan, J. (2011) · Living Reviews in Relativity · doi:10.12942/lrr-2011-2 · Cited by 880
“[34] also used the data of [440] to conclude”
BackgroundMethodOptical frequency combs: Coherently uniting the electromagnetic spectrum
Diddams, S. A., Vahala, K. J., & Udem, T. (2020) · Science · doi:10.1126/science.aay3676 · Cited by 746
“As with the microwave-to-optical mode of operation, the ratio of optical frequencies can also been interpreted to constrain physical models in which the fine-structure constant a is not in fact constant (87, 88).”
BackgroundSelf-citationSingle-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
(2019) · doi:10.1103/physrevlett.123.033201 · Cited by 711
Self-citationArchitecture for the photonic integration of an optical atomic clock
Newman, Z. L., Maurice, V. N., Drake, T. E., Stone, J. R., Briles, T. C., Spencer, D. T., Fredrick, C. D., Li, Q., Westly, D., Ilic, B., et al. (2019) · Optica · doi:10.1364/optica.6.000680 · Cited by 638
Self-citationCryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
Quantum Teleportation Between Distant Matter Qubits
Olmschenk, S., Matsukevich, D. N., Maunz, P., Hayes, D., Duan, L.-M., & Monroe, C. (2009) · Science · doi:10.1126/science.1167209 · Cited by 458
“Since its introduction, the rf ion trap has been used for a wealth of applications, including atomic clocks, measurements of fundamental constants, mass and frequency spectroscopy [35, 36, 37, 38], and, of course, quantum information [9].”
MethodA 920-Kilometer Optical Fiber Link for Frequency Metrology at the 19th Decimal Place
Predehl, K., Grosche, G., Raupach, S. M. F., Droste, S., Terra, O., Alnis, J., Legero, T., Hänsch, T. W., Udem, T., Holzwarth, R., et al. (2012) · Science · doi:10.1126/science.1218442 · Cited by 543
Pepe, F. A., Cristiani, S., Rebolo, R., Santos, N. C., Dekker, H., Cabral, A., Marcantonio, P. D., Figueira, P., Curto, G. L., Lovis, C., et al. (2020) · Astronomy and Astrophysics · doi:10.1051/0004-6361/202038306 · Cited by 596
Hunting for topological dark matter with atomic clocks
Derevianko, A., & Pospelov, M. (2014) · Nature Physics · doi:10.1038/nphys3137 · Cited by 522
“[4]) uses two co-located clocks with different sensitivity coefficients.”
BackgroundMethodInfluentialNobel Lecture: Superposition, entanglement, and raising Schrödinger’s cat
Wineland, D. J. (2013) · Reviews of Modern Physics · doi:10.1103/revmodphys.85.1103 · Cited by 511
Self-citationTheory and applications of atomic and ionic polarizabilities
Mitroy, J., Safronova, M. S., & Clark, C. W. (2010) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/43/20/202001 · Cited by 491
Demonstration of 4.8 × 10−17 stability at 1 s for two independent optical clocks
Oelker, E., Hutson, R. B., Kennedy, C. J., Sonderhouse, L., Bothwell, T., Goban, A., Kedar, D., Sanner, C., Robinson, J. M., Marti, G. E., et al. (2019) · Nature Photonics · doi:10.1038/s41566-019-0493-4 · Cited by 475
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
A clock network for geodesy and fundamental science
Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., et al. (2016) · Nature Communications · doi:10.1038/ncomms12443 · Cited by 460
Quantum State Engineering and Precision Metrology Using State-Insensitive Light Traps
Ye, J., Kimble, H. J., & Katori, H. (2008) · Science · doi:10.1126/science.1148259 · Cited by 413
Ion-trap measurements of electric-field noise near surfaces
Brownnutt, M., Kumph, M., Rabl, P., & Blatt, R. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.1419 · Cited by 413
“As another example, the effects of ion heating in optical clocks can contribute fractional uncertainties at the 10−17 level due to second-order Doppler shifts (Rosenband et al., 2008).”
BackgroundSearching for dilaton dark matter with atomic clocks
Arvanitaki, A., Huang, J., & Van Tilburg, K. (2015) · Physical Review D · doi:10.1103/physrevd.91.015015 · Cited by 404
Frequency ratio measurements at 18-digit accuracy using an optical clock network
Boulder Atomic Clock Optical Network (BACON) Collaboration*, Beloy, K., Bodine, M. I., Bothwell, T., Brewer, S. M., Bromley, S. L., Chen, J.-S., Deschênes, J.-D., Diddams, S. A., Fasano, R. J., et al. (2021) · Nature · doi:10.1038/s41586-021-03253-4 · Cited by 390
Self-citationFundamental physics with the Square Kilometre Array
Weltman, A., Bull, P., Camera, S., Kelley, K., Padmanabhan, H., Pritchard, J., Raccanelli, A., Riemer–Sørensen, S., Shao, L., Andrianomena, S., et al. (2020) · Publications of the Astronomical Society of Australia · doi:10.1017/pasa.2019.42 · Cited by 515
“However, these results are in tension with terrestrial experiments using optical atomic clocks, which set a very stringent limit on the temporal variation of α (Rosenband et al., 2008).”
ResultVarying Constants, Gravitation and Cosmology
Uzan, J. (2011) · DOAJ (DOAJ: Directory of Open Access Journals) · Cited by 392
The Buffer Gas Beam: An Intense, Cold, and Slow Source for Atoms and Molecules
Hutzler, N. R., Lu, H.-I., & Doyle, J. M. (2012) · Chemical Reviews · doi:10.1021/cr200362u · Cited by 377
Tenfold reduction of Brownian noise in high-reflectivity optical coatings
Cole, G. D., Zhang, W., Martin, M. J., Ye, J., & Aspelmeyer, M. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.174 · Cited by 381
A trapped single ion inside a Bose–Einstein condensate
Zipkes, C., Palzer, S., Sias, C., & Köhl, M. (2010) · Nature · doi:10.1038/nature08865 · Cited by 382
Prospects for a Millihertz-Linewidth Laser
Meiser, D., Ye, J., Carlson, D. R., & Holland, M. (2009) · Physical Review Letters · doi:10.1103/physrevlett.102.163601 · Cited by 378
Improved Limit on a Temporal Variation ofmp/mefrom Comparisons ofYb+and Cs Atomic Clocks
Huntemann, N., Lipphardt, B., Tamm, C., Gerginov, V., Weyers, S., & Peik, E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210802 · Cited by 366
Repetitive Readout of a Single Electronic Spin via Quantum Logic with Nuclear Spin Ancillae
Jiang, L., Hodges, J. S., Maze, J. R., Maurer, P. C., Taylor, J. M., Cory, D. G., Hemmer, P., Walsworth, R. L., Yacoby, A., Zibrov, A. S., et al. (2009) · Science · doi:10.1126/science.1176496 · Cited by 354
Single-Ion Nuclear Clock for Metrology at the 19th Decimal Place
Campbell, C. J., Radnaev, A. G., Kuzmich, A., Dzuba, V. A., Flambaum, V. V., & Derevianko, A. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.120802 · Cited by 347
Kitching, J. E., Knappe, S. A., & Donley, E. A. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2157679 · Cited by 332
“measurement is on the order of unity, but the vastly improved transition frequency still results in better overall stability, approaching at 1 s [19].”
BackgroundValentino, E. D., Said, J. L., Riess, A. G., Pollo, A., Poulin, V., Gómez-Valent, A., Weltman, A., Palmese, A., Huang, C. D., van de Bruck, C., et al. (2025) · Physics of the Dark Universe · doi:10.1016/j.dark.2025.101965 · Cited by 590
Coherent dual-comb spectroscopy at high signal-to-noise ratio
Coddington, I., Swann, W., & Newbury, N. (2010) · Physical Review A · doi:10.1103/physreva.82.043817 · Cited by 322
Self-citationHighly charged ions: Optical clocks and applications in fundamental physics
Kozlov, M. G., Safronova, M. S., López-Urrutia, J. R. C., & Schmidt, P. O. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.045005 · Cited by 302
Self-citationA precision measurement of the gravitational redshift by the interference of matter waves
Müller, H., Peters, A., & Chu, S. (2010) · Nature · doi:10.1038/nature08776 · Cited by 316
A spectrograph for exoplanet observations calibrated at the centimetre-per-second level
Wilken, T., Curto, G. L., Probst, R. A., et al. (2012) · Nature · doi:10.1038/nature11092 · Cited by 300
Progress in atomic fountains at LNE-SYRTE
Guéna, J., Abgrall, M., Rovera, D., Laurent, P., Chupin, B., Lours, M., Santarelli, G., Rosenbusch, P., Tobar, M. E., Li, R., et al. (2012) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2208 · Cited by 291
“The accuracy and stability of optical atomic clocks have now largely surpassed those of microwave clocks, and notably atomic fountain clocks [88][89][90][91].”
BackgroundEquivalence principle violations and couplings of a light dilaton
Damour, T., & Donoghue, J. F. (2010) · Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields · doi:10.1103/physrevd.82.084033 · Cited by 330
“This is about 40 times smaller than the current best atomic-clock experimental sensitivity to the variation of α [45].”
Background8 × 10^−17 fractional laser frequency instability with a long room-temperature cavity
Häfner, S., Falke, S., Grebing, C., Vogt, S., Legero, T., Merimaa, M., Lisdat, C., & Sterr, U. (2015) · Optics Letters · doi:10.1364/ol.40.002112 · Cited by 286
“//dx.doi.org/10.1364/XX.99.099999 Lasers with high frequency stability are urgently needed in various fields of physics and technology, e.g. for precision measurements, for operation of optical clocks [1, 2] or generation of low phase noise microwave signals [3]. The stability of today’s best optical clocks [4] is limi…”
BackgroundInfluentialOptical lattice clocks and quantum metrology
Katori, H. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.45 · Cited by 281
Coupled quantized mechanical oscillators
Brown, K. R., Ospelkaus, C., Colombe, Y., Wilson, A. C., Leibfried, D., & Wineland, D. J. (2011) · Nature · doi:10.1038/nature09721 · Cited by 279
“ample, it could extend the capabilities of quantum-logic spectroscopy [9, 19, 20] to ions that cannot be trapped within the same potential well as the measurement ion, such as oppositely charged ions or even anti-matter particles [9, 10].”
BackgroundSelf-citationOptical clock comparison for Lorentz symmetry testing
Sanner, C., Huntemann, N., Lange, R., Tamm, C., Peik, E., Safronova, M. S., & Porsev, S. G. (2019) · Nature · doi:10.1038/s41586-019-0972-2 · Cited by 282
Spin- 1/2 Optical Lattice Clock
Lemke, N., Ludlow, A. D., Barber, Z. W., Fortier, T. M., Diddams, S. A., Jiang, Y., Jefferts, S. R., Heavner, T. P., Parker, T. E., & Oates, C. W. (2009) · Physical Review Letters · doi:10.1103/physrevlett.103.063001 · Cited by 274
Self-citationThe CIPM list of recommended frequency standard values: guidelines and procedures
Riehle, F., Gill, P., Arias, F., & Robertsson, L. (2018) · Metrologia · doi:10.1088/1681-7575/aaa302 · Cited by 281
“These measurements included 27Al+/199Hg+ [35], 40Ca+/87Sr [36], 171Yb+(E3)/171Yb+(E2) [37], 199Hg/87Sr [38], and 171Yb/87Sr [39].”
Riehle, F. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.235 · Cited by 264
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
“Within laboratories or over short distances, fibre links can be established very easily, using similar (but usually simplified) techniques (Rosenband et al 2008) to those presented in this chapter.”
InfluentialSelf-citationOptical frequency comb with submillihertz linewidth and more than 10 W average power
Schibli, T. R., Hartl, I., Yost, D. C., Martin, M. J., Marcinkevičius, A., Fermann, M. E., & Ye, J. (2008) · Nature Photonics · doi:10.1038/nphoton.2008.79 · Cited by 262
“79" language="eng" relation="no" origsrc="yes"> Optical atomic clocks have now surpassed the best caesium frequency standards in both stability and systematic uncertaint”
BackgroundSearch for Ultralight Scalar Dark Matter with Atomic Spectroscopy
Van Tilburg, K., Leefer, N., Bougas, L., & Budker, D. (2015) · Physical Review Letters · doi:10.1103/physrevlett.115.011802 · Cited by 253
Colloquium : Physics of optical lattice clocks
Derevianko, A., & Katori, H. (2011) · Reviews of Modern Physics · doi:10.1103/revmodphys.83.331 · Cited by 254
“Fundamental research ranges from testing the effects of special and general relativity (Turyshev, 2009) to probing time-variation of fundamental constants (Rosenband et al., 2008).”
BackgroundInfluentialExperimental realization of an optical second with strontium lattice clocks
Le Targat, R., Lorini, L., Le Coq, Y., Zawada, M., Guéna, J., Abgrall, M., Gurov, M., Rosenbusch, P., Rovera, D. G., Nagórny, B., et al. (2013) · Nature Communications · doi:10.1038/ncomms3109 · Cited by 250
Self-citationSub-milliwatt-level microresonator solitons with extended access range using an auxiliary laser
Zhang, S., Silver, J. M., Bino, L. D., Copie, F., Woodley, M. T. M., Ghalanos, G. N., Svela, A. Ø., Moroney, N., & Del’Haye, P. (2019) · Optica · doi:10.1364/optica.6.000206 · Cited by 249
Ultrastable lasers based on vibration insensitive cavities
Millo, J., Magalhães, D. V., Mandache, C., Coq, Y. L., English, E., Westergaard, P. G., Lodewyck, J., Bize, S., Lemonde, P., & Santarelli, G. (2009) · Physical Review A · doi:10.1103/physreva.79.053829 · Cited by 244
Invited Article: A compact optically coherent fiber frequency comb
Sinclair, L. C., Deschênes, J.-D., Sonderhouse, L., Swann, W. C., Khader, I. H., Baumann, E., Newbury, N. R., & Coddington, I. R. (2015) · Review of Scientific Instruments · doi:10.1063/1.4928163 · Cited by 236
Self-citationPrecision atomic physics techniques for nuclear physics with radioactive beams
Blaum, K., Dilling, J., & Nörtershäuser, W. (2013) · Physica Scripta · doi:10.1088/0031-8949/2013/t152/014017 · Cited by 236
Cavity-Enhanced Direct Frequency Comb Spectroscopy: Technology and Applications
Adler, F., Thorpe, M. J., Cossel, K. C., & Ye, J. (2010) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-060908-155248 · Cited by 244
Searching for Dark Matter and Variation of Fundamental Constants with Laser and Maser Interferometry
Stadnik, Y. V., & Flambaum, V. V. (2015) · Physical Review Letters · doi:10.1103/physrevlett.114.161301 · Cited by 246
“10−17/yr [10].”
BackgroundHees, A., Guéna, J., Abgrall, M., Bize, S., & Wolf, P. (2016) · Physical Review Letters · doi:10.1103/physrevlett.117.061301 · Cited by 249
Frequency ratio of Yb and Sr clocks with 5 × 10−17 uncertainty at 150 seconds averaging time
Nemitz, N., Ohkubo, T., Takamoto, M., Ushijima, I., Das, M., Ohmae, N., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.20 · Cited by 221
“depth of U 0 = 100 E r , the results correspond to a fractional frequency shift of (Δν bg / ν Yb ) / Δ𝑓relVG = −1.9(1.4)×10−18/GHz. For an alignment of the VBG centre-frequency according to 𝑓relVG= 0(5) GHz in normal operation, we include a fractional uncertainty of 1.2×10−17 (at 100 E r ) in the lattice light shift u…”
BackgroundMethodInfluentialKennedy, C. J., Oelker, E. G., Robinson, J. M., Bothwell, T., Kedar, D., Milner, W. R., Marti, G. E., Derevianko, A., & Ye, J. (2020) · Physical Review Letters · doi:10.1103/physrevlett.125.201302 · Cited by 219
Single-ion quantum lock-in amplifier
Kotler, S., Akerman, N., Glickman, Y., Keselman, A., & Ozeri, R. (2011) · Nature · doi:10.1038/nature10010 · Cited by 212
“is multiplied by either sin(2ˇf mt) or cos(2ˇf mt) and the two results are integrated over an integration window 3 T, I lock in= 1 T Z T 0 M(t) cos(2ˇf mt)dt Q lock in= 1 T Z T 0 M(t) sin(2ˇf mt)dt: (1) The signal S 0 is proportional to (I2 lock in + Q 2 lock in ) 1=2. The constant phase ’can be extracted by tan(’) =…”
BackgroundMicroscopic Control and Detection of Ultracold Strontium in Optical-Tweezer Arrays
Norcia, M. A., Young, A. W., & Kaufman, A. M. (2018) · Physical Review X · doi:10.1103/physrevx.8.041054 · Cited by 226
“It further would be suitable for fundamental studies of squeezing and long-range entanglement on an optical clock transition [34, 48, 72, 73].”
BackgroundOperation of an optically coherent frequency comb outside the metrology lab
Sinclair, L. C., Coddington, I. R., Swann, W. C., Rieker, G. B., Hati, A., Iwakuni, K., & Newbury, N. R. (2014) · Optics Express · doi:10.1364/oe.22.006996 · Cited by 210
Self-citationESPRESSO: The next European exoplanet hunter
Pepe, F., Molaro, P., Cristiani, S., Rebolo, R., Santos, N., Dekker, H., Mégevand, D., Zerbi, F., Cabral, A., Marcantonio, P. D., et al. (2014) · Astronomische Nachrichten · doi:10.1002/asna.201312004 · Cited by 161
“For example, the constancy of the fine structure constant α is ensured to within a few parts per 10−17 over a 1-yr period (Rosenband et al. 2008).”
BackgroundQuantum tests of the Einstein Equivalence Principle with the STE–QUEST space mission
Altschul, B., Bailey, Q. G., Blanchet, L., Bongs, K., Bouyer, P., Cacciapuoti, L., Capozziello, S., Gaaloul, N., Giulini, D., Hartwig, J., et al. (2015) · Advances in Space Research · doi:10.1016/j.asr.2014.07.014 · Cited by 204
Improved Limits for Violations of Local Position Invariance from Atomic Clock Comparisons
Lange, R., Huntemann, N., Rahm, J. M., Sanner, C., Shao, H., Lipphardt, B., Tamm, C., Weyers, S., & Peik, E. (2021) · Physical Review Letters · doi:10.1103/physrevlett.126.011102 · Cited by 200
Increasing Sensing Resolution with Error Correction
Arrad, G., Vinkler-Aviv, Y., Aharonov, D., & Retzker, A. (2014) · Physical Review Letters · doi:10.1103/physrevlett.112.150801 · Cited by 207
Rellergert, W. G., DeMille, D. P., Greco, R. R., Hehlen, M. P., Torgerson, J. R., & Hudson, E. R. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.200802 · Cited by 200
Berengut, J. C., Dzuba, V. A., & Flambaum, V. V. (2010) · Physical Review Letters · doi:10.1103/physrevlett.105.120801 · Cited by 186
Probing New Long-Range Interactions by Isotope Shift Spectroscopy
Berengut, J. C., Budker, D., Cedric Delaunay, B., Flambaum, V. V., Frugiuele, C., Fuchs, E., Grojean, C., Harnik, R., Ozeri, R., Pérez, G., et al. (2018) · Physical Review Letters · doi:10.1103/physrevlett.120.091801 · Cited by 190
Quantum simulations with cold trapped ions
Johanning, M., Varón, A. F., & Wunderlich, C. (2009) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/0953-4075/42/15/154009 · Cited by 208
“Today, by using trapped ions as frequency standards unsurpassed ccuracy and precision has been reached (e.g., [Rosenband et al. 2008] and references ther in), and in addition, trapped ions are used for a wide range of investigations into fundamental questions of physics, for instance in the field…”
BackgroundSpectral and temporal characterization of a fused-quartz-microresonator optical frequency comb
Papp, S. B., & Diddams, S. A. (2011) · Physical Review A · doi:10.1103/physreva.84.053833 · Cited by 180
Self-citationSpace clocks and fundamental tests: The ACES experiment
Cacciapuoti, L., & Salomon, C. (2009) · The European Physical Journal Special Topics · doi:10.1140/epjst/e2009-01041-7 · Cited by 187
Enhancing quantum sensing sensitivity by a quantum memory
Zaiser, S., Rendler, T., Jakobi, I., Wolf, T. A., Lee, S., Wagner, S., Bergholm, V., Schulte‐Herbrüggen, T., Neumann, P., & Wrachtrup, J. (2016) · Nature Communications · doi:10.1038/ncomms12279 · Cited by 180
The status of varying constants: a review of the physics, searches and implications
Martins, C. J. A. P. (2017) · Reports on Progress in Physics · doi:10.1088/1361-6633/aa860e · Cited by 179
Hite, D. A., Colombe, Y., Wilson, A. C., Brown, K. R., Warring, U., Jördens, R., Jost, J. D., McKay, K. S., Pappas, D. P., Leibfried, D., et al. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.103001 · Cited by 176
Self-citationExtreme Ultraviolet Frequency Comb Metrology
Kandula, D. Z., Gohle, C., Pinkert, T. J., Ubachs, W., & Eikema, K. S. E. (2010) · Physical Review Letters · doi:10.1103/physrevlett.105.063001 · Cited by 169
Towards a redefinition of the second based on optical atomic clocks
Riehle, F. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.012 · Cited by 174
“storage of a chain of multiple ions. To use a transition with a small natural line width often a quadrupole transition (e.g. 2S 1=2 - D 5=2) is employed like in the Ca +[14, 15, 16], Sr [17, 18], Hg+ [19], or Yb [20, 21] clocks (Fig. 2). All these transitions have a natural lifetime that supports a line width on the o…”
MethodA strontium lattice clock with 3 × 10−17inaccuracy and its frequency
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., et al. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/073023 · Cited by 182
“In addition to their role as future primary standards, optical clocks are of interest as sensitive probes in areas such as relativistic geodesy [9], tests of relativity [10, 11], and searches for variations of fundamental constants [1, 12, 13, 14, 15].”
BackgroundInfluentialCoherent optical clock down-conversion for microwave frequencies with 10 −18 instability
Nakamura, T., Davila-Rodriguez, J., Leopardi, H., Sherman, J. A., Fortier, T. M., Xie, X., Campbell, J. C., McGrew, W. F., Zhang, X., Hassan, Y. S., et al. (2020) · Science · doi:10.1126/science.abb2473 · Cited by 169
Self-citationOptical flywheels with attosecond jitter
Benedick, A., Fujimoto, J. G., & Käertner, F. X. (2012) · Nature Photonics · doi:10.1038/nphoton.2011.326 · Cited by 168
Long-distance frequency transfer over an urban fiber link using optical phase stabilization
Jiang, H., Kéfélian, F., Crane, S. G., Lopez, O., Lours, M., Millo, J., Holleville, D., Lemonde, P., Chardonnet, C., Amy‐Klein, A., et al. (2008) · Journal of the Optical Society of America B · doi:10.1364/josab.25.002029 · Cited by 166
Absolute Frequency Measurement of the Ca+40 4s S1/22−3d D5/22 Clock Transition
Chwalla, M., Benhelm, J., Kim, K., Kirchmair, G., Monz, T., Riebe, M., Schindler, P., Villar, A. S., Hänsel, W., Roos, C. F., et al. (2009) · Physical Review Letters · doi:10.1103/physrevlett.102.023002 · Cited by 165
Relaxion stars and their detection via atomic physics
Banerjee, A., Budker, D., Eby, J., Kim, H., & Perez, G. (2020) · Communications Physics · doi:10.1038/s42005-019-0260-3 · Cited by 163
Theoretical aspects of the equivalence principle
Damour, T. (2012) · Classical and Quantum Gravity · doi:10.1088/0264-9381/29/18/184001 · Cited by 164
Optical frequency transfer via 146 km fiber link with 10^−19 relative accuracy
Grosche, G., Terra, O., Predehl, K., Holzwarth, R., Lipphardt, B., Vogt, F., Sterr, U., & Schnatz, H. (2009) · Optics Letters · doi:10.1364/ol.34.002270 · Cited by 161
Strong Limit on a Variable Proton-to-Electron Mass Ratio from Molecules in the Distant Universe
Murphy, M. T., Flambaum, V. V., Müller, S., & Henkel, C. (2008) · Science · doi:10.1126/science.1156352 · Cited by 159
2 Theoretical Aspects of the Equivalence PrinciplePreprint
Damour, T. (2016) · Cited by 174
Metadata
- Authors
- Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., Diddams, S. A., Swann, W. C., Newbury, N. R., Itano, W. M., Wineland, D. J., & Bergquist, J. C.
- Affiliations
- National Institute of Standards and Technology (US)
- Corresponding author
- Rosenband, T.
- Schmidt, P. O.
- Lorini, L.
- Oskay, W. H.
- Stalnaker, J. E.
- ORCID
- Venue
- Science
- Published
- 2008-03-28
- Volume
- 319
- Issue
- 5871
- Pages
- 1808-1812
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1997269293
- Cited by
- 1,450
- References
- 31
- Citations by year
- 2026: 27 · 2025: 62 · 2024: 52 · 2023: 44 · 2022: 43 · 2021: 50 · 2020: 60 · 2019: 78 · 2018: 65 · 2017: 76 · 2016: 85 · 2015: 96 · 2014: 129 · 2013: 99 · 2012: 99
- FWCI
- 73.95
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Science (publishedVersion)
- PubMed (publishedVersion)
- CINECA IRIS Institutional Research Information System (IRIS Istituto Nazionale di Ricerca Metrologica) (submittedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Keywords
- optical atomic clocks, aluminum ions, mercury ions, frequency ratio, frequency metrology, fine-structure constant variation, systematic uncertainties
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review