The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
The cytosensor microphysiometer: biological applications of silicon technology
Abstract
A silicon-based device, dubbed a microphysiometer, can be used to detect and monitor the response of cells to a variety of chemical substances, especially ligands for specific plasma membrane receptors. The microphysiometer measures the rate of proton excretion from 10(4) to 10(6) cells. This article gives an overview of experiments currently being carried out with this instrument with emphasis on receptors with seven transmembrane helices and tyrosine kinase receptors. As a scientific instrument, the microphysiometer can be thought of as serving two distinct functions. In terms of detecting specific molecules, selected biological cells in this instrument serve as detectors and amplifiers. The microphysiometer can also investigate cell function and biochemistry. A major application of this instrument may prove to be screening for new receptor ligands. In this respect, the microphysiometer appears to offer significant advantages over other techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Identification of Heregulin, a Specific Activator of p185 erbB2
Holmes, W. E., Sliwkowski, M. X., Akita, R. W., Henzel, W. J., Lee, J., Park, J. W., Yansura, D., Abadi, N., Raab, H., Lewis, G. D., et al. (1992) · Science · doi:10.1126/science.256.5060.1205 · Cited by 962
Light-Addressable Potentiometric Sensor for Biochemical Systems
Hafeman, D. G., Parce, J. W., & McConnell, H. M. (1988) · Science · doi:10.1126/science.3375810 · Cited by 709
Self-citationDetection of Cell-Affecting Agents with a Silicon Biosensor
Parce, J. W., Owicki, J. C., Kercso, K. M., Sigal, G. B., Wada, H. G., Muir, V. C., Bousse, L. J., Ross, K. L., Sikic, B. I., & McConnell, H. M. (1989) · Science · doi:10.1126/science.2799384 · Cited by 295
Self-citationOwicki, J. C., & Wallace Parce, J. (1992) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(92)87004-9 · Cited by 273
Self-citationFraser, C. M., Wang, C. D., Robinson, D. A., Gocayne, J. D., & Venter, J. C. (1989) · Molecular Pharmacology · doi:10.1016/s0026-895x(25)09700-7 · Cited by 259
Continuous monitoring of receptor-mediated changes in the metabolic rates of living cells.
Owicki, J. C., Parce, J. W., Kercso, K. M., Sigal, G. B., Muir, V. C., Venter, J. C., Fraser, C. M., & McConnell, H. M. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.10.4007 · Cited by 124
Self-citationRaley-Susman, K., Miller, K., Owicki, J., & Sapolsky, R. (1992) · Journal of Neuroscience · doi:10.1523/jneurosci.12-03-00773.1992 · Cited by 45
Self-citation
Cited by
Nanotube Molecular Wires as Chemical Sensors
Kong, J., Franklin, N. R., Zhou, C., Chapline, M. G., Peng, S., Cho, K., & Dai, H. (2000) · Science · doi:10.1126/science.287.5453.622 · Cited by 6,043
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Supported Membranes: Scientific and Practical Applications
Sackmann, E. (1996) · Science · doi:10.1126/science.271.5245.43 · Cited by 2,151
Isolation and Characterization of a Novel Endogenous Peptide Ligand for the Human APJ Receptor
Tatemoto, K., Hosoya, M., Habata, Y., Fujii, R., Kakegawa, T., Zou, M.-X., Kawamata, Y., Fukusumi, S., Hinuma, S., Kitada, C., et al. (1998) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.1998.9489 · Cited by 1,685
Hong, S., Gronert, K., Devchand, P. R., Moussignac, R.-L., & Serhan, C. N. (2003) · Journal of Biological Chemistry · doi:10.1074/jbc.m300218200 · Cited by 1,000
Analysis and Interpretation of Microplate-Based Oxygen Consumption and pH Data
Divakaruni, A. S., Paradyse, A., Ferrick, D. A., Murphy, A. N., & Jastroch, M. (2014) · Methods in Enzymology · doi:10.1016/b978-0-12-801415-8.00016-3 · Cited by 518
Mitochondria buffer physiological calcium loads in cultured rat dorsal root ganglion neurons
Werth, J., & Thayer, S. (1994) · The Journal of Neuroscience · doi:10.1523/jneurosci.14-01-00348.1994 · Cited by 488
Dopamine receptors: Molecular biology, biochemistry and behavioural aspects
Jackson, D. M., & Westlind-Danielsson, A. (1994) · Pharmacology & Therapeutics · doi:10.1016/0163-7258(94)90041-8 · Cited by 483
Integration of Cell Culture and Microfabrication Technology
Park, T. H., & Shuler, M. L. (2003) · Biotechnology Progress · doi:10.1021/bp020143k · Cited by 473
Advances in measuring cellular bioenergetics using extracellular flux
Ferrick, D. A., Neilson, A., & Beeson, C. (2008) · Drug Discovery Today · doi:10.1016/j.drudis.2007.12.008 · Cited by 460
Hierlemann, A., & Gutierrez-Osuna, R. (2008) · Chemical Reviews · doi:10.1021/cr068116m · Cited by 456
Ostuni, E., Yan, L., & Whitesides, G. M. (1999) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00004-1 · Cited by 453
Supported membranes on soft polymer cushions: fabrication, characterization and applications
Sackmann, E., & Tanaka, M. (2000) · Trends in Biotechnology · doi:10.1016/s0167-7799(99)01412-2 · Cited by 417
Peptide Agonist of the Thrombopoietin Receptor as Potent as the Natural Cytokine
Cwirla, S. E., Balasubramanian, P., Duffin, D. J., Wagstrom, C. R., Gates, C. M., Singer, S. C., Davis, A. M., Tansik, R. L., Mattheakis, L. C., Boytos, C. M., et al. (1997) · Science · doi:10.1126/science.276.5319.1696 · Cited by 403
Boniface, J. J., Rabinowitz, J. D., Wülfing, C., Hampl, J., Reich, Z., Altman, J. D., Kantor, R. M., Beeson, C., McConnell, H. M., & Davis, M. M. (1998) · Immunity · doi:10.1016/s1074-7613(00)80629-9 · Cited by 373
Self-citationSin, A., Chin, K. C., Jamil, M. F., Kostov, Y., Rao, G., & Shuler, M. L. (2008) · Biotechnology Progress · doi:10.1021/bp034077d · Cited by 368
Cell-Based Biosensors and Their Application in Biomedicine
Liu, Q., Wu, C., Cai, H., Hu, N., Zhou, J., & Wang, P. (2014) · Chemical Reviews · doi:10.1021/cr2003129 · Cited by 348
Bousse, L. (1996) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(96)01906-5 · Cited by 345
Microfabrication in Biology and Medicine
Voldman, J., Gray, M. L., & Schmidt, M. A. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.401 · Cited by 344
Zhang, J., Nuebel, E., Wisidagama, D. R. R., Setoguchi, K., Hong, J. S., Van Horn, C. M., Imam, S. S., Vergnes, L., Malone, C. S., Koehler, C. M., et al. (2012) · Nature Protocols · doi:10.1038/nprot.2012.048 · Cited by 282
Ziegler, A., Nervi, P., Dürrenberger, M., & Seelig, J. (2005) · Biochemistry · doi:10.1021/bi0491604 · Cited by 266
Comparison of the hysteresis of Ta2O5 and Si3N4 pH-sensing insulators
Bousse, L., Mostarshed, S., van der Schoot, B., & de Rooij, N. F. (1994) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(94)87044-6 · Cited by 177
Torisawa, Y.-S., Shiku, H., Yasukawa, T., Nishizawa, M., & Matsue, T. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.05.028 · Cited by 124
Metadata
- Authors
- McConnell, H., Owicki, J., Parce, J., Miller, D., Baxter, G., Wada, H., & Pitchford, S.
- Venue
- Science
- Published
- 1992-09-25
- Volume
- 257
- Issue
- 5078
- Pages
- 1906-1912
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2036213823
- Cited by
- 622
- References
- 7
- FWCI
- 7.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.