The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Ionic Mechanisms Controlling Behavioral Responses of Paramecium to Mechanical Stimulation
Abstract
A mechanical stimulus applied to the anterior part of Paramecium causes a transient increase in membrane permeability to calcium. This permits a calcium current to flow into the cell, causing the membrane potential to approach the equilibrium level for calcium. The transient depolarization which results elicits a reversal in the direction of ciliary beat. When the organisms are free-swimming this is seen as the reversed locomotion of Jennings' "avoiding reaction." In contrast, a mechanical stimulus applied to the posterior part results in increased permeability to potassium ions, and hence an outward potassium current. The hyperpolarization which results causes an increase in the frequency of ciliary beat in the normal direction. In free-swimming specimens this is seen as an increase in the velocity of forward locomotion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Croonian Lecture - Ionic movements and electrical activity in giant nerve fibres
Hodgkin, A. L. (1958) · Proceedings of the Royal Society of London. Series B - Biological Sciences · doi:10.1098/rspb.1958.0001 · Cited by 499
Ionic Control of the Reversal Response of Cilia in Paramecium caudatum
Naitoh, Y. (1968) · The Journal of General Physiology · doi:10.1085/jgp.51.1.85 · Cited by 127
Self-citation
Cited by
Adler, J. (1969) · Science · doi:10.1126/science.166.3913.1588 · Cited by 667
Fluid Mechanics of Planktonic Microorganisms
Guasto, J. S., Rusconi, R., & Stocker, R. (2012) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-120710-101156 · Cited by 542
Calcium Entry Leads to Inactivation of Calcium Channel in Paramecium
Brehm, P., & Eckert, R. (1978) · Science · doi:10.1126/science.103199 · Cited by 533
Self-citationEckert, R. (1972) · Science · doi:10.1126/science.176.4034.473 · Cited by 518
Self-citationReactivated Triton-Extracted Models of Paramecium : Modification of Ciliary Movement by Calcium Ions
Naitoh, Y., & Kaneko, H. (1972) · Science · doi:10.1126/science.176.4034.523 · Cited by 442
Self-citationA Mechanosensitive Ion Channel in the Yeast Plasma Membrane
Gustin, M. C., Zhou, X.-L., Martinac, B., & Kung, C. (1988) · Science · doi:10.1126/science.2460920 · Cited by 374
Marcos, Fu, H. C., Powers, T. R., & Stocker, R. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1120955109 · Cited by 302
Localization of calcium channels in Paramecium caudatum.
Dunlap, K. (1977) · The Journal of Physiology · doi:10.1113/jphysiol.1977.sp011993 · Cited by 259
Ueki, N., Matsunaga, S., Inouye, I., & Hallmann, A. (2010) · BMC Biology · doi:10.1186/1741-7007-8-103 · Cited by 59
Electrogenesis in the lower Metazoa and implications for neuronal integration
Meech, R. W. (2015) · Journal of Experimental Biology · doi:10.1242/jeb.111955 · Cited by 20
Anesthetic action of volatile anesthetics by using Paramecium as a model
Zhou, M., Xia, H., Xu, Y., Xin, N., Liu, J., & Zhang, S. (2012) · Journal of Huazhong University of Science and Technology [Medical Sciences] · doi:10.1007/s11596-012-0071-1 · Cited by 7
Metadata
- Authors
- Naitoh, Y., & Eckert, R.
- Venue
- Science
- Published
- 1969-05-23
- Volume
- 164
- Issue
- 3882
- Pages
- 963-965
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2007314601
- Cited by
- 288
- References
- 2
- FWCI
- 4.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.