The DOI matches its Crossref record.
Atomic Force Microscopy and Dissection of Gap Junctions
Abstract
An atomic force microscope (AFM) was used to study the structure of isolated hepatic gap junctions in phosphate-buffered saline (PBS). The thickness of these gap junctions appears to be 14.4 nanometers, close to the dimensions reported by electron microscopy (EM). When an increasing force is applied to the microscope tip, the top membrane of the gap junction can be "dissected" away, leaving the extracellular domains of the bottom membrane exposed. When such "force dissection" is performed on samples both trypsinized and fixed with glutaraldehyde, the hexagonal array of gap junction hemichannels is revealed, with a center-to-center spacing of 9.1 nanometers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pérez, S., & Bertoft, E. (2010) · Starch - Stärke · doi:10.1002/star.201000013 · Cited by 1,492
Connections with Connexins: the Molecular Basis of Direct Intercellular Signaling
Bruzzone, R., White, T. W., & Paul, D. L. (1996) · European Journal of Biochemistry · doi:10.1111/j.1432-1033.1996.0001q.x · Cited by 1,302
Imaging modes of atomic force microscopy for application in molecular and cell biology
Dufrêne, Y. F., Ando, T., Garcia, R., Alsteens, D., Martinez-Martin, D., Engel, A., Gerber, C., & Müller, D. J. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.45 · Cited by 945
From Molecules to Cells: Imaging Soft Samples with the Atomic Force Microscope
Radmacher, M., Tillmann, R. W., Fritz, M., & Gaub, H. E. (1992) · Science · doi:10.1126/science.1411505 · Cited by 900
Emerging issues of connexin channels: biophysics fills the gap
L. Harris, A. (2001) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583501003705 · Cited by 800
High-speed atomic force microscopy for nano-visualization of dynamic biomolecular processes
Ando, T., Uchihashi, T., & Fukuma, T. (2008) · Progress in Surface Science · doi:10.1016/j.progsurf.2008.09.001 · Cited by 558
Reproducible Imaging and Dissection of Plasmid DNA Under Liquid with the Atomic Force Microscope
Hansma, H. G., Vesenka, J., Siegerist, C., Kelderman, G., Morrett, H., Sinsheimer, R. L., Elings, V., Bustamante, C., & Hansma, P. K. (1992) · Science · doi:10.1126/science.256.5060.1180 · Cited by 517
Deformation and height anomaly of soft surfaces studied with an AFM
Weisenhorn, A. L., Khorsandi, M., Kasas, S., Gotzos, V, & Butt, H. J. (1993) · Nanotechnology · doi:10.1088/0957-4484/4/2/006 · Cited by 427
Actin Filament Dynamics in Living Glial Cells Imaged by Atomic Force Microscopy
Henderson, E., Haydon, P. G., & Sakaguchi, D. S. (1992) · Science · doi:10.1126/science.1411511 · Cited by 415
Biological applications of atomic force microscopy
Lal, R., & John, S. A. (1994) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1994.266.1.c1 · Cited by 402
Self-citationImaging and manipulation of biological structures with the AFM
Fotiadis, D. (2002) · Micron · doi:10.1016/s0968-4328(01)00026-9 · Cited by 390
Nielsen, M. S., Nygaard Axelsen, L., Sorgen, P. L., Verma, V., Delmar, M., & Holstein‐Rathlou, N. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c110051 · Cited by 386
AFM: a versatile tool in biophysics
Alessandrini, A., & Facci, P. (2005) · Measurement Science and Technology · doi:10.1088/0957-0233/16/6/r01 · Cited by 384
Barbee, K. A., Davies, P. F., & Lal, R. (1994) · Circulation Research · doi:10.1161/01.res.74.1.163 · Cited by 350
Self-citationMapping interaction forces with the atomic force microscope
Radmacher, M., Cleveland, J. P., Fritz, M., Hansma, H. G., & Hansma, P. K. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)81011-2 · Cited by 332
Biological atomic force microscopy: what is achieved and what is needed
Shao, Z., Mou, J., Czajkowsky, D. M., Yang, J., & Yuan, J.-Y. (1996) · Advances in Physics · doi:10.1080/00018739600101467 · Cited by 325
Bian, K., Gerber, C., Heinrich, A. J., Müller, D. J., Scheuring, S., & Jiang, Y. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00033-2 · Cited by 314
Native Escherichia coli OmpF Porin Surfaces Probed by Atomic Force Microscopy
Schabert, F. A., Henn, C., & Engel, A. (1995) · Science · doi:10.1126/science.7701347 · Cited by 279
Müller, D. J., & Engel, A. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78195-5 · Cited by 257
Human cornea and sclera studied by atomic force microscopy
Meller, D., Meller, K., & Peters, K. (1997) · Cell and Tissue Research · doi:10.1007/s004410050798 · Cited by 88
Metadata
- Authors
- Hoh, J. H., Lal, R., John, S. A., Revel, J.-P., & Arnsdorf, M. F.
- Venue
- Science
- Published
- 1991-09-20
- Volume
- 253
- Issue
- 5026
- Pages
- 1405-1408
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1995685967
- Cited by
- 245
- References
- 0
- FWCI
- 7.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.