The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
In Situ Interfacial Mass Detection with Piezoelectric Transducers
Abstract
The converse piezoelectric effect, in which an electric field applied across a piezoelectric material induces a stress in that material, has spurred many recent developments in mass measurement techniques. These methods commonly rely on the changes in the vibrational resonant frequency of piezoelectric quartz oscillators that result from changes in mass on the surface of the oscillator. The dependence of frequency on mass has been exploited extensively for mass measurements in vacuum or gas phase, for example, thickness monitors for thin-film preparation and sensors for chemical agents. Advances in piezoelectric methodology in the last decade now allow dynamic measurements of minute mass changes (< 10 -9 grams per square centimeter) at surfaces, thin films, and electrode interfaces in liquid media as well. Mass measurements associated with a diverse collection of interfacial processes can be readily performed, including chemical and biological sensors, reactions catalyzed by enzymes immobilized on surfaces, electron transfer at and ion exchange in thin polymer films, and doping reactions of conducting polymers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Verwendung von Schwingquarzen zur W�gung d�nner Schichten und zur Mikrow�gung
Sauerbrey, G. (1959) · Zeitschrift f�r Physik · doi:10.1007/bf01337937 · Cited by 9,653
Use of quartz vibration for weighing thin films on a microbalance
Sauerbrey, G., & Sauerbrey, F. (1959) · The European Physical Journal A · Cited by 6,791
Piezoelectric Sorption Detector.
King, W. H. (1964) · Analytical Chemistry · doi:10.1021/ac60215a012 · Cited by 786
Mechanism of operation and design considerations for surface acoustic wave device vapour sensors
Wohltjen, H. (1984) · Sensors and Actuators · doi:10.1016/0250-6874(84)85014-3 · Cited by 465
Electrochemical applications of the quartz crystal microbalance
Deakin, M. R., & Buttry, D. A. (1989) · Analytical Chemistry · doi:10.1021/ac00195a001 · Cited by 323
Self-citationMicrogravimetric immunoassay with piezoelectric crystals
Roederer, J. E., & Bastiaans, G. J. (1983) · Analytical Chemistry · doi:10.1021/ac00264a030 · Cited by 298
Ebersole, R. C., Miller, J. A., Moran, J. R., & Ward, M. D. (1990) · Journal of the American Chemical Society · doi:10.1021/ja00164a070 · Cited by 208
Self-citationSelection of adsorbates for chemical sensor arrays by pattern recognition
Carey, W. P., Beebe, K. R., Kowalski, B. R., Illman, D. L., & Hirschfeld, T. (1986) · Analytical Chemistry · doi:10.1021/ac00292a036 · Cited by 200
VISCOELASTIC PROPERTIES OF DILUTE POLYMER SOLUTIONS
Ferry, J. D. (1979) · Macromolecular Chemistry · doi:10.1016/b978-0-08-022039-0.50009-6 · Cited by 198
Ballantine, D. S., Rose, S. L., Grate, J. W., & Wohltjen, H. (1986) · Analytical Chemistry · doi:10.1021/ac00127a035 · Cited by 191
Parathion antibodies on piezoelectric crystals
Ngeh-Ngwainbi, J., Foley, P. H., Kuan, S. S., et al. (1986) · Journal of the American Chemical Society · doi:10.1021/ja00278a012 · Cited by 171
Underpotential metal deposition on gold, monitored in situ with a quartz microbalance
Deakin, M. R., & Melroy, O. (1988) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/0022-0728(88)80288-2 · Cited by 166
Direct determination of the mass of an underpotentially deposited monolayer of lead on gold
Melroy, O. R., Kanazawa, K. K., Gordon, J. G., & Buttry, D. A. (1986) · Langmuir · doi:10.1021/la00072a003 · Cited by 138
Self-citationMolecular sieve sensors for selective detection at the nanogram level
Bein, T., Brown, K., Frye, G. C., & Brinker, C. J. (1989) · Journal of the American Chemical Society · doi:10.1021/ja00201a069 · Cited by 130
Odour-sensing system using a quartz-resonator sensor array and neural-network pattern recognition
Ema, K., Yokoyama, M., Nakamoto, T., & Moriizumi, T. (1989) · Sensors and Actuators · doi:10.1016/0250-6874(89)87036-2 · Cited by 121
Cited by
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Soft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
Cantilever transducers as a platform for chemical and biological sensors
Lavrik, N. V., Sepaniak, M. J., & Datskos, P. G. (2004) · Review of Scientific Instruments · doi:10.1063/1.1763252 · Cited by 1,117
Reviakine, I., Johannsmann, D., & Richter, R. P. (2011) · Analytical Chemistry · doi:10.1021/ac201778h · Cited by 871
A review of atmospheric aerosol measurements
McMurry, P. (2000) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00455-0 · Cited by 832
Metadata
- Authors
- Ward, M. D., & Buttry, D. A.
- Venue
- Science
- Published
- 1990-08-31
- Volume
- 249
- Issue
- 4972
- Pages
- 1000-1007
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2042537980
- Cited by
- 525
- References
- 15
- FWCI
- 18.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.