The DOI matches its Crossref record.
Bipolar Spin Switch
Abstract
A thin ferromagnetic film can be used to polarize the spin axes of the electrons carrying an electric current in a manner loosely analogous with a light polarizer. When such a film is fabricated on a gold film, a nonequilibrium population of spin-polarized electrons is built up in the gold causing a "spin bottleneck" effect. The addition of a second ferromagnetic film results in a device whose output voltage depends on the orientation of the spins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Spintronics: Fundamentals and applications
Žutić, I., Fabian, J., & Das Sarma, S. (2004) · Reviews of Modern Physics · doi:10.1103/revmodphys.76.323 · Cited by 11,268
Electrical spin injection and accumulation at room temperature in an all-metal mesoscopic spin valve
Jedema, F. J., Filip, A. T., & van Wees, B. J. (2001) · Nature · doi:10.1038/35066533 · Cited by 1,152
Fabian, J., Matos-Abiague, A., Ertler, C., Stano, P., & Žutić, I. (2007) · Acta Physica Slovaca. Reviews and Tutorials · doi:10.2478/v10155-010-0086-8 · Cited by 798
Bader, S. D., & Parkin, S. S. P. (2010) · Annual Review of Condensed Matter Physics · doi:10.1146/annurev-conmatphys-070909-104123 · Cited by 700
Control of Spin Precession in a Spin-Injected Field Effect Transistor
Koo, H. C., Kwon, J. H., Eom, J., Chang, J., Han, S. H., & Johnson, M. (2009) · Science · doi:10.1126/science.1173667 · Cited by 584
Self-citationFuture perspectives for spintronic devices
Hirohata, A., & Takanashi, K. (2014) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/47/19/193001 · Cited by 559
Spin dynamics in semiconductors
Wu, M. W., Jiang, J. H., & Weng, M. Q. (2010) · Physics Reports · doi:10.1016/j.physrep.2010.04.002 · Cited by 555
Extrinsic magnetotransport phenomena in ferromagnetic oxides
Ziese, M. (2002) · Reports on Progress in Physics · doi:10.1088/0034-4885/65/2/202 · Cited by 487
Separation of enantiomers by their enantiospecific interaction with achiral magnetic substrates
Banerjee-Ghosh, K., Ben Dor, O., Tassinari, F., Capua, E., Yochelis, S., Capua, A., Yang, S.-H., Parkin, S. S. P., Sarkar, S., Kronik, L., et al. (2018) · Science · doi:10.1126/science.aar4265 · Cited by 460
Spin-based logic in semiconductors for reconfigurable large-scale circuits
Dery, H., Dalal, P., Cywiński, Ł., & Sham, L. J. (2007) · Nature · doi:10.1038/nature05833 · Cited by 429
Spin injection and spin accumulation in all-metal mesoscopic spin valves
Jedema, F. J., Nijboer, M. S., Filip, & van Wees, B. J. (2003) · Physical Review B · doi:10.1103/physrevb.67.085319 · Cited by 312
Giant Magnetoresistance in Magnetic Layered and Granular Materials
(1994) · Solid State Physics · doi:10.1016/s0081-1947(08)60642-6 · Cited by 258
Solid state magnetic field sensors and applications
Heremans, J. (1993) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/26/8/001 · Cited by 252
Enantioseparation by crystallization using magnetic substrates
Tassinari, F., Steidel, J., Paltiel, S., Fontanesi, C., Lahav, M., Paltiel, Y., & Naaman, R. (2019) · Chemical Science · doi:10.1039/c9sc00663j · Cited by 101
Metadata
- Authors
- Johnson, M.
- Venue
- Science
- Published
- 1993-04-16
- Volume
- 260
- Issue
- 5106
- Pages
- 320-323
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1967516209
- Cited by
- 221
- References
- 0
- FWCI
- 6.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.