The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Confinement of Electrons to Quantum Corrals on a Metal Surface
Abstract
A method for confining electrons to artificial structures at the nanometer lengthscale is presented. Surface state electrons on a copper(111) surface were confined to closed structures (corrals) defined by barriers built from iron adatoms. The barriers were assembled by individually positioning iron adatoms with the tip of a 4-kelvin scanning tunneling microscope (STM). A circular corral of radius 71.3 Å was constructed in this way out of 48 iron adatoms. Tunneling spectroscopy performed inside of the corral revealed a series of discrete resonances, providing evidence for size quantization. STM images show that the corral's interior local density of states is dominated by the eigenstate density expected for an electron trapped in a round two-dimensional box.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Positioning single atoms with a scanning tunnelling microscope
Eigler, D. M., & Schweizer, E. K. (1990) · Nature · doi:10.1038/344524a0 · Cited by 3,161
Self-citationZangwill, A. (1988) · Cambridge University Press eBooks · doi:10.1017/cbo9780511622564 · Cited by 1,999
Bound-State Eigenfunctions of Classically Chaotic Hamiltonian Systems: Scars of Periodic Orbits
Heller, E. J. (1984) · Physical Review Letters · doi:10.1103/physrevlett.53.1515 · Cited by 1,476
Imaging standing waves in a two-dimensional electron gas
Crommie, M. F., Lutz, C. P., & Eigler, D. M. (1993) · Nature · doi:10.1038/363524a0 · Cited by 1,276
Self-citationAtomic and Molecular Manipulation with the Scanning Tunneling Microscope
Stroscio, J. A., & Eigler, D. M. (1991) · Science · doi:10.1126/science.254.5036.1319 · Cited by 1,131
Self-citationDirect observation of standing wave formation at surface steps using scanning tunneling spectroscopy
Hasegawa, Y., & Avouris, P. (1993) · Physical Review Letters · doi:10.1103/physrevlett.71.1071 · Cited by 631
Imaging Xe with a low-temperature scanning tunneling microscope
Eigler, D. M., Weiss, P. S., Schweizer, E. K., & Lang, N. D. (1991) · Physical Review Letters · doi:10.1103/physrevlett.66.1189 · Cited by 274
Self-citationSpectroscopy of a single adsorbed atom
Crommie, M. F., Lutz, C. P., & Eigler, D. M. (1993) · Physical review. B, Condensed matter · doi:10.1103/physrevb.48.2851 · Cited by 106
Self-citation
Cited by
Ab initio modeling of quantum transport properties of molecular electronic devices
Taylor, J., Guo, H., & Wang, J. (2001) · Physical Review B · doi:10.1103/physrevb.63.245407 · Cited by 3,497
Advances in atomic force microscopy
Giessibl, F. J. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.949 · Cited by 2,278
Nanotubes as nanoprobes in scanning probe microscopy
Dai, H., Hafner, J. H., Rinzler, A. G., Colbert, D. T., & Smalley, R. E. (1996) · Nature · doi:10.1038/384147a0 · Cited by 2,211
New Approaches to Nanofabrication: Molding, Printing, and Other Techniques
Gates, B. D., Xu, Q., Stewart, M., Ryan, D., Willson, C. G., & Whitesides, G. M. (2005) · Chemical Reviews · doi:10.1021/cr030076o · Cited by 2,020
Unconventional Methods for Fabricating and Patterning Nanostructures
Xia, Y., Rogers, J. A., Paul, K. E., & Whitesides, G. M. (1999) · Chemical Reviews · doi:10.1021/cr980002q · Cited by 1,538
Metadata
- Authors
- Crommie, M. F., Lutz, C. P., & Eigler, D. M.
- Venue
- Science
- Published
- 1993-10-08
- Volume
- 262
- Issue
- 5131
- Pages
- 218-220
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2074071059
- Cited by
- 1,690
- References
- 8
- FWCI
- 26.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.