The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Atomic Resolution of the Silicon (111)-(7×7) Surface by Atomic Force Microscopy
Open accessAbstract
Achieving high resolution under ultrahigh-vacuum conditions with the force microscope can be difficult for reactive surfaces, where the interaction forces between the tip and the samples can be relatively large. A force detection scheme that makes use of a modified cantilever beam and senses the force gradient through frequency modulation is described. The reconstructed silicon (111)-(7×7) surface was imaged in a noncontact mode by force microscopy with atomic resolution (6 angstroms lateral, 0.1 angstrom vertical).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1994) · doi:10.1201/9780429246593 · Cited by 40,500
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Frequency modulation detection using high-Q cantilevers for enhanced force microscope sensitivity
Albrecht, T. R., Grütter, P., Horne, D., & Rugar, D. (1991) · Journal of Applied Physics · doi:10.1063/1.347347 · Cited by 2,434
7 × 7 Reconstruction on Si(111) Resolved in Real Space
Binnig, G., Rohrer, H., Gerber, C., & Weibel, E. (1983) · Physical Review Letters · doi:10.1103/physrevlett.50.120 · Cited by 1,930
Structural analysis of Si(111)-7×7 by UHV-transmission electron diffraction and microscopy
Takayanagi, K., Tanishiro, Y., Takahashi, M., & Takahashi, S. (1985) · Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films · doi:10.1116/1.573160 · Cited by 1,317
True Atomic Resolution by Atomic Force Microscopy Through Repulsive and Attractive Forces
Ohnesorge, F., & Binnig, G. (1993) · Science · doi:10.1126/science.260.5113.1451 · Cited by 700
Observation of metallic adhesion using the scanning tunneling microscope
Dürig, U., Züger, O., & Pohl, D. W. (1990) · Physical Review Letters · doi:10.1103/physrevlett.65.349 · Cited by 182
Scanning force microscopy on the Si(111)7�7 surface reconstruction
Howald, L., L�thi, R., Meyer, E., G�thner, P., & G�ntherodt, H. J. (1994) · The European Physical Journal B · doi:10.1007/bf01312696 · Cited by 39
Cited by
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 3,709
Advances in atomic force microscopy
Giessibl, F. J. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.949 · Cited by 2,278
Self-citationDynamic atomic force microscopy methods
García, R. (2002) · Surface Science Reports · doi:10.1016/s0167-5729(02)00077-8 · Cited by 2,076
The surface science of nanocrystals
Boles, M. A., Ling, D., Hyeon, T., & Talapin, D. V. (2016) · Nature Materials · doi:10.1038/nmat4526 · Cited by 1,742
Combining Machine Learning and Computational Chemistry for Predictive Insights Into Chemical Systems
Keith, J. A., Vassilev-Galindo, V., Cheng, B., Chmiela, S., Gastegger, M., Müller, K.-R., & Tkatchenko, A. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00107 · Cited by 849
Metadata
- Authors
- Giessibl, F. J.
- Venue
- Science
- Published
- 1995-01-06
- Volume
- 267
- Issue
- 5194
- Pages
- 68-71
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1980745639
- Cited by
- 1,189
- References
- 8
- FWCI
- 19.04
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.