The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Scanning Interferometric Apertureless Microscopy: Optical Imaging at 10 Angstrom Resolution
Abstract
Interferometric near-field optical microscopy achieving a resolution of 10 angstroms is demonstrated. The scattered electric field variation caused by a vibrating probe tip in close proximity to a sample surface is measured by encoding it as a modulation in the optical phase of one arm of an interferometer. Unlike in regular near-field optical microscopes, where the contrast results from a weak source (or aperture) dipole interacting with the polarizability of the sample, the present form of imaging relies on a fundamentally different contrast mechanism: sensing the dipole-dipole coupling of two externally driven dipoles (the tip and sample dipoles) as their spacing is modulated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2020) · Electromagnetic Processes · doi:10.2307/j.ctv131bv37.5 · Cited by 21,966
Light Scattering by Small Particles
Van de Hulst, H. C., & Twersky, V. (1957) · Physics Today · doi:10.1063/1.3060205 · Cited by 5,619
Optical stethoscopy: Image recording with resolution λ/20
Pohl, D. W., Denk, W., & Lanz, M. (1984) · Applied Physics Letters · doi:10.1063/1.94865 · Cited by 2,040
Near-Field Optics: Microscopy, Spectroscopy, and Surface Modification Beyond the Diffraction Limit
Betzig, E., & Trautman, J. K. (1992) · Science · doi:10.1126/science.257.5067.189 · Cited by 1,808
Atomic force microscope–force mapping and profiling on a sub 100-Å scale
Martin, Y., Williams, C. C., & Wickramasinghe, H. K. (1987) · Journal of Applied Physics · doi:10.1063/1.338807 · Cited by 1,428
Self-citationSingle Molecules Observed by Near-Field Scanning Optical Microscopy
Betzig, E., & Chichester, R. J. (1993) · Science · doi:10.1126/science.262.5138.1422 · Cited by 1,262
Super-resolution Aperture Scanning Microscope
ASH, E. A., & NICHOLLS, G. (1972) · Nature · doi:10.1038/237510a0 · Cited by 953
Development of a 500 Å spatial resolution light microscope
Lewis, A., Isaacson, M., Harootunian, A., & Muray, A. (1984) · Ultramicroscopy · doi:10.1016/0304-3991(84)90201-8 · Cited by 757
Cited by
New Polymer Synthesis by Nitroxide Mediated Living Radical Polymerizations
Hawker, C. J., Bosman, A. W., & Harth, E. (2001) · Chemical Reviews · doi:10.1021/cr990119u · Cited by 3,850
Metal-Catalyzed Living Radical Polymerization
Kamigaito, M., Ando, T., & Sawamoto, M. (2001) · Chemical Reviews · doi:10.1021/cr9901182 · Cited by 3,275
Science and technology roadmap for graphene, related two-dimensional crystals, and hybrid systems
Ferrari, A. C., Bonaccorso, F., Fal'ko, V., Novoselov, K. S., Roche, S., Bøggild, P., Borini, S., Koppens, F. H. L., Palermo, V., Pugno, N., et al. (2015) · Nanoscale · doi:10.1039/c4nr01600a · Cited by 3,027
Nanoscale chemical analysis by tip-enhanced Raman spectroscopy
Stöckle, R. M., Suh, Y. D., Deckert, V., & Zenobi, R. (2000) · Chemical Physics Letters · doi:10.1016/s0009-2614(99)01451-7 · Cited by 1,606
Dendrimers in Supramolecular Chemistry: From Molecular Recognition to Self-Assembly
Zeng, F., & Zimmerman, S. C. (1997) · Chemical Reviews · doi:10.1021/cr9603892 · Cited by 1,406
Metadata
- Authors
- Zenhausern, F., Martin, Y., & Wickramasinghe, H. K.
- Venue
- Science
- Published
- 1995-08-25
- Volume
- 269
- Issue
- 5227
- Pages
- 1083-1085
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2039945745
- Cited by
- 692
- References
- 8
- FWCI
- 29.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.