Forskolin Stimulation of Water and Cation Permeability in Aquaporin1 Water Channels
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Aquaporin1, a six-transmembrane domain protein, is a water channel present in many fluid-secreting and -absorbing cells. In Xenopus oocytes injected with aquaporin1 complementary RNA, the application of forskolin or cyclic 8-bromo- adenosine 3′,5′-monophosphate increased membrane permeability to water and triggered a cationic conductance. The cationic conductance was also induced by direct injection of protein kinase A (PKA) catalytic subunit, reduced by the kinase inhibitor H7, and blocked by HgCl 2 , an inhibitor of aquaporin1. The cationic permeability of the aquaporin1 channel is activated by a cyclic adenosine monophosphate-dependent mechanism that may involve direct or indirect phosphorylation by PKA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Appearance of Water Channels in Xenopus Oocytes Expressing Red Cell CHIP28 Protein
Preston, G. M., Carroll, T. P., Guggino, W. B., & Agre, P. (1992) · Science · doi:10.1126/science.256.5055.385 · Cited by 2,059
Preston, G. M., & Agre, P. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.24.11110 · Cited by 816
Distribution of the aquaporin CHIP in secretory and resorptive epithelia and capillary endothelia.
Nielsen, S., Smith, B. L., Christensen, E. I., & Agre, P. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.15.7275 · Cited by 781
Aquaporin CHIP: the archetypal molecular water channel
Agre, P., Preston, G. M., Smith, B. L., Jung, J. S., Raina, S., Moon, C., Guggino, W. B., & Nielsen, S. (1993) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.1993.265.4.f463 · Cited by 685
A transient calcium‐dependent chloride current in the immature Xenopus oocyte.
Barish, M. E. (1983) · The Journal of Physiology · doi:10.1113/jphysiol.1983.sp014852 · Cited by 621
The mercury-sensitive residue at cysteine 189 in the CHIP28 water channel.
Preston, G. M., Jung, J. S., Guggino, W. B., & Agre, P. (1993) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)54108-9 · Cited by 592
Raina, S., Preston, G. M., Guggino, W. B., & Agre, P. (1995) · Journal of Biological Chemistry · doi:10.1074/jbc.270.4.1908 · Cited by 409
Transport of water and urea in red blood cells
Macey, R. I. (1984) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1984.246.3.c195 · Cited by 382
Chang, X. B., Tabcharani, J. A., Hou, Y. X., Jensen, T. J., Kartner, N., Alon, N., Hanrahan, J. W., & Riordan, J. R. (1993) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)82125-1 · Cited by 296
Ether-à-go-go encodes a voltage-gated channel permeable to K+ and Ca2+ and modulated by cAMP
Brüggemann, A., Pardo, L. A., Stühmer, W., & Pongs, O. (1993) · Nature · doi:10.1038/365445a0 · Cited by 241
Cited by
Aquaporins in the Kidney: From Molecules to Medicine
Nielsen, S., Frøkiær, J., Marples, D., Kwon, T.-H., Agre, P., & Knepper, M. A. (2002) · Physiological Reviews · doi:10.1152/physrev.00024.2001 · Cited by 1,251
Structure of a Glycerol-Conducting Channel and the Basis for Its Selectivity
Fu, D., Libson, A., Miercke, L. J. W., Weitzman, C., Nollert, P., Krucinski, J., & Stroud, R. M. (2000) · Science · doi:10.1126/science.290.5491.481 · Cited by 1,000
Cellular and Molecular Biology of the Aquaporin Water Channels
Borgnia, M., Nielsen, S., Engel, A., & Agre, P. (1999) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.68.1.425 · Cited by 846
Structure and function of aquaporin water channels
Verkman, A. S., & Mitra, A. K. (2000) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.2000.278.1.f13 · Cited by 750
AQUAPORINS AND WATER PERMEABILITY OF PLANT MEMBRANES
Maurel, C. (1997) · Annual Review of Plant Physiology and Plant Molecular Biology · doi:10.1146/annurev.arplant.48.1.399 · Cited by 559
Rapid gating and anion permeability of an intracellular aquaporin
Yasui, M., Hazama, A., Kwon, T.-H., Nielsen, S., Guggino, W. B., & Agre, P. (1999) · Nature · doi:10.1038/46045 · Cited by 500
Molecular Characterization of a Broad Selectivity Neutral Solute Channel
Tsukaguchi, H., Shayakul, C., Berger, U. V., Mackenzie, B., Devidas, S., Guggino, W. B., van Hoek, A. N., & Hediger, M. A. (1998) · Journal of Biological Chemistry · doi:10.1074/jbc.273.38.24737 · Cited by 478
The Aquaporins, Blueprints for Cellular Plumbing Systems
Agre, P., Bonhivers, M., & Borgnia, M. J. (1998) · Journal of Biological Chemistry · doi:10.1074/jbc.273.24.14659 · Cited by 463
Yang, B., & Verkman, A. S. (1997) · Journal of Biological Chemistry · doi:10.1074/jbc.272.26.16140 · Cited by 393
Effect of expressing the water channel aquaporin-1 on the CO2 permeability of Xenopus oocytes
Nakhoul, N. L., Davis, B. A., Romero, M. F., & Boron, W. F. (1998) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1998.274.2.c543 · Cited by 383
Aquaporin water channels in mammals
Ishibashi, K., Hara, S., & Kondo, S. (2009) · Clinical and Experimental Nephrology · doi:10.1007/s10157-008-0118-6 · Cited by 365
Weig, A., Deswarte, C., & Chrispeels, M. J. (1997) · Plant Physiology · doi:10.1104/pp.114.4.1347 · Cited by 250
Schäffner, A. R. (1998) · Planta · doi:10.1007/s004250050239 · Cited by 243
“A recent report by Yool et al. (1996) indicating that phosphorylation of mammalian AQP1 induces an ion conductivity could not be reproduced by several laboratories (Agre et al.”
BackgroundHigh-resolution x-ray structure of human aquaporin 5
Horsefield, R., Nordén, K., Fellert, M., Backmark, A., Törnroth-Horsefield, S., Terwisscha van Scheltinga, A. C., Kvassman, J., Kjellbom, P., Johanson, U., & Neutze, R. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0801466105 · Cited by 216
Aquaporin water channels and lung physiology
Verkman, A. S., Matthay, M. A., & Song, Y. (2000) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.2000.278.5.l867 · Cited by 212
Visualization of a water-selective pore by electron crystallography in vitreous ice
Ren, G., Reddy, V. S., Cheng, A., Melnyk, P., & Mitra, A. K. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.98.4.1398 · Cited by 183
Yang, B., Fukuda, N., van Hoek, A., Matthay, M. A., Ma, T., & Verkman, A. S. (2000) · Journal of Biological Chemistry · doi:10.1074/jbc.275.4.2686 · Cited by 181
Cloned Human Aquaporin-1 Is a Cyclic GMP-Gated Ion Channel
Anthony, T. L., Brooks, H. L., Boassa, D., Leonov, S., Yanochko, G. M., Regan, J. W., & Yool, A. J. (2000) · Molecular Pharmacology · doi:10.1016/s0026-895x(24)26424-5 · Cited by 179
Self-citationMechanism of Gating and Ion Conductivity of a Possible Tetrameric Pore in Aquaporin-1
Yu, J., Yool, A. J., Schulten, K., & Tajkhorshid, E. (2006) · Structure · doi:10.1016/j.str.2006.07.006 · Cited by 158
“…of reversal potentials demonstrated that the current response is associated with a nonselective cation conductance, having approximately equal permeability to Na+, K+, and Cs+, lower but measurable permeability to tetraethylammonium ion, and no appreciable Cl2 permeability (Yool et al., 1996).”
BackgroundSelf-citationLiu, K., Kozono, D., Kato, Y., Agre, P., Hazama, A., & Yasui, M. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0409232102 · Cited by 84
Metadata
- Authors
- Yool, A. J., Stamer, W. D., & Regan, J. W.
- Venue
- Science
- Published
- 1996-08-30
- Volume
- 273
- Issue
- 5279
- Pages
- 1216-1218
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2031638883
- Cited by
- 173
- References
- 15
- FWCI
- 4.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.