The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Scanning Single-Electron Transistor Microscopy: Imaging Individual Charges
Abstract
A single-electron transistor scanning electrometer (SETSE)—a scanned probe microscope capable of mapping static electric fields and charges with 100-nanometer spatial resolution and a charge sensitivity of a small fraction of an electron—has been developed. The active sensing element of the SETSE, a single-electron transistor fabricated at the end of a sharp glass tip, is scanned in close proximity across the sample surface. Images of the surface electric fields of a GaAs/Al x Ga 1− x As heterostructure sample show individual photo-ionized charge sites and fluctuations in the dopant and surface-charge distribution on a length scale of 100 nanometers. The SETSE has been used to image and measure depleted regions, local capacitance, band bending, and contact potentials at submicrometer length scales on the surface of this semiconductor sample.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Observation of single-electron charging effects in small tunnel junctions
Fulton, T. A., & Dolan, G. J. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.109 · Cited by 1,295
Self-citationAshoori, R. C. (1996) · Nature · doi:10.1038/379413a0 · Cited by 1,198
Observation of single charge carriers by force microscopy
Schönenberger, C., & Alvarado, S. F. (1990) · Physical Review Letters · doi:10.1103/physrevlett.65.3162 · Cited by 267
Ballistic conductance of interacting electrons in the quantum Hall regime
Chklovskii, D. B., Matveev, K. A., & Shklovskii, B. I. (1993) · Physical Review B · doi:10.1103/physrevb.47.12605 · Cited by 193
Diagnostics of individual quasi-one-dimensional electronic channels
Larkin, I. A., & Shikin, V. B. (1990) · Physics Letters A · doi:10.1016/0375-9601(90)90293-w · Cited by 29
Cited by
From Molecules to Crystal Engineering: Supramolecular Isomerism and Polymorphism in Network Solids
Moulton, B., & Zaworotko, M. J. (2001) · Chemical Reviews · doi:10.1021/cr9900432 · Cited by 6,395
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Observation of electron–hole puddles in graphene using a scanning single-electron transistor
Martin, J., Akerman, N., Ulbricht, G., Lohmann, T., Smet, J. H., von Klitzing, K., & Yacoby, A. (2008) · Nature Physics · doi:10.1038/nphys781 · Cited by 1,566
Single-electron devices and their applications
Likharev, K. K. (1999) · Proceedings of the IEEE · doi:10.1109/5.752518 · Cited by 1,453
Electric-field sensing using single diamond spins
Dolde, F., Fedder, H., Doherty, M. W., Nöbauer, T., Rempp, F., Balasubramanian, G., Wolf, T., Reinhard, F., Hollenberg, L. C. L., Jelezko, F., et al. (2011) · Nature Physics · doi:10.1038/nphys1969 · Cited by 1,334
Metadata
- Authors
- Yoo, M. J., Fulton, T. A., Hess, H. F., Willett, R. L., Dunkleberger, L. N., Chichester, R. J., Pfeiffer, L. N., & West, K. W.
- Venue
- Science
- Published
- 1997-04-25
- Volume
- 276
- Issue
- 5312
- Pages
- 579-582
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2019176261
- Cited by
- 323
- References
- 5
- FWCI
- 17.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.