The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Exceeding 5000-Fold Concentration of Dilute Analytes in Micellar Electrokinetic Chromatography
Abstract
When a neutral analyte zone is injected into a charged pseudostationary phase, the length of the zone is predicted to be narrowed by 1/(1 + k ), where k is the retention factor. The conditions for zone narrowing to occur assume negligible electroosmotic flow, a relatively constant electric field along the capillary column, and no pseudostationary phase in the injected analyte mixture. The theoretically expected concentration enhancement was demonstrated experimentally. Consequently, the detection sensitivity of analytes in micellar electrokinetic chromatography (MEKC) can be improved significantly. For example, 9 to 18 parts per billion of an environmentally important racemic herbicide spiked in lake water was separated by MEKC and detected by ultraviolet absorption.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrokinetic separations with micellar solutions and open-tubular capillaries
Terabe, S., Otsuka, K., Ichikawa, K., Tsuchiya, A., & Ando, T. (1984) · Analytical Chemistry · doi:10.1021/ac00265a031 · Cited by 1,970
Self-citation
Cited by
Samsidar, A., Siddiquee, S., & Shaarani, S. M. (2018) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2017.11.011 · Cited by 416
Breadmore, M. C., Shallan, A. I., Rabanes, H. R., Gstoettenmayr, D., Abdul Keyon, A. S., Gaspar, A., Dawod, M., & Quirino, J. P. (2013) · ELECTROPHORESIS · doi:10.1002/elps.201200396 · Cited by 372
Self-citationSweeping of Analyte Zones in Electrokinetic Chromatography
Quirino, J. P., & Terabe, S. (1999) · Analytical Chemistry · doi:10.1021/ac9810866 · Cited by 349
Self-citationOn-line sample preconcentration in capillary electrophoresis
Simpson, S. L., Quirino, J. P., & Terabe, S. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.11.001 · Cited by 342
Self-citationOn-line preconcentration methods for capillary electrophoresis
Osbourn, D. M., Weiss, D. J., & Lunte, C. E. (2000) · Electrophoresis · doi:10.1002/1522-2683(20000801)21:14<2768::aid-elps2768>3.0.co;2-p · Cited by 327
Chen, Y., Guo, Z., Wang, X., & Qiu, C. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.026 · Cited by 316
Britz-McKibbin, P., & Chen, D. D. Y. (2000) · Analytical Chemistry · doi:10.1021/ac990898e · Cited by 310
Handbook of Affinity Chromatography
(2005) · CRC Press eBooks · doi:10.1201/9780824751982 · Cited by 310
Microfluidic Temperature Gradient Focusing
Ross, D., & Locascio, L. E. (2002) · Analytical Chemistry · doi:10.1021/ac025528w · Cited by 278
High-Resolution NMR Spectroscopy of Sample Volumes from 1 nL to 10 μL
Lacey, M. E., Subramanian, R., Olson, D. L., Webb, A. G., & Sweedler, J. V. (1999) · Chemical Reviews · doi:10.1021/cr980140f · Cited by 252
Wang, C., Li, C., Zang, X., Han, D., Liu, Z., & Wang, Z. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.01.027 · Cited by 56
Metadata
- Authors
- Quirino, J. P., & Terabe, S.
- Venue
- Science
- Published
- 1998-10-16
- Volume
- 282
- Issue
- 5388
- Pages
- 465-468
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2005086794
- Cited by
- 644
- References
- 1
- FWCI
- 26.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.