Prolonged Activation of Mitochondrial Conductances During Synaptic Transmission
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Although ion channels have been detected in mitochondria, scientists have not been able to record ion transport in mitochondria of intact cells. A variation of the patch clamp technique was used to record ion channel activity from intracellular organelles in the presynaptic terminal of the squid. Electron microscopy indicated that mitochondria are numerous in this terminal and are the only organelles compatible with the tips of the pipettes. Before synaptic stimulation, channel activity was infrequent and its conductance was small, although large conductances (∼0.5 to 2.5 nanosiemens) could be detected occasionally. During a train of action potentials, the conductance of the mitochondrial membrane increased up to 60-fold. The conductance increased after a delay of several hundred milliseconds and continued to increase after stimulation had stopped. Recovery occurred over tens of seconds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coupling of phosphorylation to electron and hydrogen transfer by a chemi-osmotic type of mechanism
MITCHELL, P. (1961) · Nature · doi:10.1038/191144a0 · Cited by 4,704
Close Contacts with the Endoplasmic Reticulum as Determinants of Mitochondrial Ca 2+ Responses
Rizzuto, R., Pinton, P., Carrington, W., Fay, F. S., Fogarty, K. E., Lifshitz, L. M., Tuft, R. A., & Pozzan, T. (1998) · Science · doi:10.1126/science.280.5370.1763 · Cited by 2,257
Mechanisms by which mitochondria transport calcium
Gunter, T. E., & Pfeiffer, D. R. (1990) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1990.258.5.c755 · Cited by 1,640
Mitochondria and calcium ion transport
Lehninger, A. L. (1970) · Biochemical Journal · doi:10.1042/bj1190129 · Cited by 835
Mitochondrial Involvement in Post-Tetanic Potentiation of Synaptic Transmission
Tang, Y.-G., & Zucker, R. S. (1997) · Neuron · doi:10.1016/s0896-6273(00)81248-9 · Cited by 441
Cited by
Mitochondria and neuronal activity
Kann, O., & Kovács, R. (2007) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00222.2006 · Cited by 855
Mitochondria in health and disease: perspectives on a new mitochondrial biology
Duchen, M. R. (2004) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2004.03.001 · Cited by 721
Alavian, K. N., Beutner, G., Lazrove, E., Sacchetti, S., Park, H.-A., Licznerski, P., Li, H., Nabili, P., Hockensmith, K., Graham, M., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1401591111 · Cited by 592
Self-citationEmptage, N. J., Reid, C. A., & Fine, A. (2001) · Neuron · doi:10.1016/s0896-6273(01)00190-8 · Cited by 522
VDAC: The channel at the interface between mitochondria and the cytosol
Colombini, M. (2004) · Molecular and Cellular Biochemistry · doi:10.1023/b:mcbi.0000009862.17396.8d · Cited by 499
Metadata
- Authors
- Jonas, E. A., Buchanan, J., & Kaczmarek, L. K.
- Venue
- Science
- Published
- 1999-11-12
- Volume
- 286
- Issue
- 5443
- Pages
- 1347-1350
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2044090667
- Cited by
- 94
- References
- 5
- FWCI
- 1.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.