The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Microrobots for Micrometer-Size Objects in Aqueous Media: Potential Tools for Single-Cell Manipulation
Abstract
Conducting polymers are excellent materials for actuators that are operated in aqueous media. Microactuators based on polypyrrole-gold bilayers enable large movement of structures attached to these actuators and are of particular interest for the manipulation of biological objects, such as single cells. A fabrication method for creating individually addressable and controllable polypyrrole-gold microactuators was developed. With these individually controlled microactuators, a micrometer-size manipulator, or microrobotic arm, was fabricated. This microrobotic arm can pick up, lift, move, and place micrometer-size objects within an area of about 250 micrometers by 100 micrometers, making the microrobot an excellent tool for single-cell manipulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Fractional Quantum Hall Effect in Organic Molecular Semiconductors
Schön, J. H., Kloc, C., & Batlogg, B. (2000) · Science · doi:10.1126/science.288.5475.2338 · Cited by 212
RetractedXia, Y., & Whitesides, G. M. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980316)37:5<550::aid-anie550>3.0.co;2-g · Cited by 4,285
Controlled Folding of Micrometer-Size Structures
Smela, E., Inganäs, O., & Lundström, I. (1995) · Science · doi:10.1126/science.268.5218.1735 · Cited by 586
Microfabrication of PPy microactuators and other conjugated polymer devices
Smela, E. (1999) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/9/1/001 · Cited by 318
Mechanism of electromechanical actuation in polypyrrole
Gandhi, M. R., Murray, P., Spinks, G. M., & Wallace, G. G. (1995) · Synthetic Metals · doi:10.1016/0379-6779(95)80022-0 · Cited by 267
Conjugated polymers and the bending cantilever method: Electrical muscles and smart devices
Pei, Q., & Inganläs, O. (1992) · Advanced Materials · doi:10.1002/adma.19920040406 · Cited by 192
Jager, E. W. H., Smela, E., & Inganäs, O. (1999) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(99)00159-8 · Cited by 50
Self-citationFuhr, G., & Shirley, S. G. (1995) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/5/2/006 · Cited by 39
Cited by
Soft Actuators for Small-Scale Robotics
Hines, L., Petersen, K., Lum, G. Z., & Sitti, M. (2017) · Advanced Materials · doi:10.1002/adma.201603483 · Cited by 1,337
Stimuli-responsive polymers and their applications
Wei, M., Gao, Y., Li, X., & Serpe, M. J. (2017) · Polymer Chemistry · doi:10.1039/c6py01585a · Cited by 1,298
Controlled Propulsion of Artificial Magnetic Nanostructured Propellers
Ghosh, A., & Fischer, P. (2009) · Nano Letters · doi:10.1021/nl900186w · Cited by 1,296
Conjugated Polymer Actuators for Biomedical Applications
Smela, E. (2003) · Advanced Materials · doi:10.1002/adma.200390113 · Cited by 1,177
Evidence for Recent Groundwater Seepage and Surface Runoff on Mars
Malin, M. C., & Edgett, K. S. (2000) · Science · doi:10.1126/science.288.5475.2330 · Cited by 1,082
Metadata
- Authors
- Jager, E. W. H., Inganäs, O., & Lundström, I.
- Venue
- Science
- Published
- 2000-06-30
- Volume
- 288
- Issue
- 5475
- Pages
- 2335-2338
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2094083886
- Cited by
- 578
- References
- 8
- FWCI
- 13.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.