The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
The Use of a Charge-Coupled Device for Quantitative Optical Microscopy of Biological Structures
Abstract
The properties of a charge-coupled device (CCD) and its application to the high-resolution analysis of biological structures by optical microscopy are described. The CCD, with its high resolution, high sensitivity, wide dynamic range, photometric accuracy, and geometric stability, can provide data of such high quality that quantitative analysis on two- and three-dimensional microscopic images is possible. For example, the three-dimensional imaging properties of an epifluorescence microscope have been quantitatively determined with the CCD. This description of the imaging properties of the microscope, and the high-quality image data provided by the CCD, allow sophisticated computational image processing methods to be used that greatly improve the effective resolution obtainable for biological structures. Image processing techniques revealed fine substructures in Drosophila embryonic diploid chromosomes in two and three dimensions. The same approach can be extended to structures as small as yeast chromosomes or to other problems in structural cell biology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The embryonic cell lineage of the nematode Caenorhabditis elegans
Sulston, J. E., Schierenberg, E., White, J. G., & Thomson, J. N. (1983) · Developmental Biology · doi:10.1016/0012-1606(83)90201-4 · Cited by 4,199
Williams, D. A., Fogarty, K. E., Tsien, R. Y., & Fay, F. S. (1985) · Nature · doi:10.1038/318558a0 · Cited by 657
Optical Sectioning Microscopy: Cellular Architecture in Three Dimensions
Agard, D. A. (1984) · Annual Review of Biophysics and Bioengineering · doi:10.1146/annurev.bb.13.060184.001203 · Cited by 475
Self-citationHiraoka, Y., Toda, T., & Yanagida, M. (1984) · Cell · doi:10.1016/0092-8674(84)90013-8 · Cited by 474
Self-citationThe frequency response of a defocused optical system
Hopkins, H. H. (1955) · Proceedings of the Royal Society of London A Mathematical and Physical Sciences · doi:10.1098/rspa.1955.0158 · Cited by 465
Three-dimensional architecture of a polytene nucleus
Agard, D. A., & Sedat, J. W. (1983) · Nature · doi:10.1038/302676a0 · Cited by 446
Self-citationApplications of fluorescence in the biomedical sciences
Taylor, D. L., Waggoner, A. S., Lanni, F., Murphy, R. F., & Birge, R. (1986) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Cited by 371
Inoué, S. (1986) · Springer eBooks · doi:10.1007/978-1-4757-6925-8 · Cited by 342
Properties of a Defocused Optical System*
Stokseth, P. A. (1969) · Journal of the Optical Society of America · doi:10.1364/josa.59.001314 · Cited by 305
Connor, J. A. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.16.6179 · Cited by 294
Spatial organization of chromosomes in the salivary gland nuclei of Drosophila melanogaster.
Hochstrasser, M., Mathog, D., Gruenbaum, Y., Saumweber, H., & Sedat, J. W. (1986) · The Journal of cell biology · doi:10.1083/jcb.102.1.112 · Cited by 272
Self-citationLocalization of antigenic determinants in whole Drosophila embryos
Mitchison, T. J., & Sedat, J. (1983) · Developmental Biology · doi:10.1016/0012-1606(83)90275-0 · Cited by 262
Self-citationCharacteristic folding pattern of polytene chromosomes in Drosophila salivary gland nuclei
Mathog, D., Hochstrasser, M., Gruenbaum, Y., Saumweber, H., & Sedat, J. (1984) · Nature · doi:10.1038/308414a0 · Cited by 178
Self-citationVisualization of Individual DNA Molecules in Solution by Light Microscopy: DAPI Staining Method1
Morikawa, K., & Yanagida, M. (1981) · The Journal of Biochemistry · doi:10.1093/oxfordjournals.jbchem.a133247 · Cited by 149
New Observations on Cell Architecture and Dynamics by Video-Enhanced Contrast Optical Microscopy
ALLEN, R. D. (1985) · Annual Review of Biophysics and Biophysical Chemistry · doi:10.1146/annurev.bb.14.060185.001405 · Cited by 136
Matsumoto, S., Morikawa, K., & Yanagida, M. (1981) · Journal of Molecular Biology · doi:10.1016/0022-2836(81)90255-2 · Cited by 91
Ginzberg, E. (1982) · Scientific American · doi:10.1038/scientificamerican0982-66 · Cited by 84
Cited by
Fluorescence lifetime imaging of free and protein-bound NADH.
Lakowicz, J. R., Szmacinski, H., Nowaczyk, K., & Johnson, M. L. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.4.1271 · Cited by 766
Fluorescent Probes of Cell Signaling
Tsien, R. Y. (1989) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.12.030189.001303 · Cited by 652
Chapter 13 Fluorescence Microscopy in Three Dimensions
Agard, D. A., Hiraoka, Y., Shaw, P., & Sedat, J. W. (1989) · Methods in Cell Biology · doi:10.1016/s0091-679x(08)60986-3 · Cited by 649
Self-citationHuman genome organization: Alu, LINES, and the molecular structure of metaphase chromosome bands
Korenberg, J. R., & Rykowski, M. C. (1988) · Cell · doi:10.1016/0092-8674(88)90159-6 · Cited by 557
Three-Dimensional Imaging by Deconvolution Microscopy
McNally, J. G., Karpova, T., Cooper, J., & Conchello, J. A. (1999) · Methods · doi:10.1006/meth.1999.0873 · Cited by 449
Metadata
- Authors
- Hiraoka, Y., Sedat, J. W., & Agard, D. A.
- Venue
- Science
- Published
- 1987-10-02
- Volume
- 238
- Issue
- 4823
- Pages
- 36-41
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2025224752
- Cited by
- 300
- References
- 17
- FWCI
- 32.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.