The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Adhesion Forces Between Individual Ligand-Receptor Pairs
Abstract
The adhesion force between the tip of an atomic force microscope cantilever derivatized with avidin and agarose beads functionalized with biotin, desthiobiotin, or iminobiotin was measured. Under conditions that allowed only a limited number of molecular pairs to interact, the force required to separate tip and bead was found to be quantized in integer multiples of 160 ± 20 piconewtons for biotin and 85 ± 15 piconewtons for iminobiotin. The measured force quanta are interpreted as the unbinding forces of individual molecular pairs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intermolecular and Surface Forces
(2011) · Intermolecular and Surface Forces · doi:10.1016/b978-0-12-391927-4.10024-6 · Cited by 16,923
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Mechanotransduction Across the Cell Surface and Through the Cytoskeleton
Wang, N., Butler, J. P., & Ingber, D. E. (1993) · Science · doi:10.1126/science.7684161 · Cited by 3,003
Optical trapping and manipulation of single cells using infrared laser beams
Ashkin, A., Dziedzic, J. M., & Yamane, T. (1987) · Nature · doi:10.1038/330769a0 · Cited by 2,303
Direct observation of kinesin stepping by optical trapping interferometry
Svoboda, K., Schmidt, C. F., Schnapp, B. J., & Block, S. M. (1993) · Nature · doi:10.1038/365721a0 · Cited by 1,910
Direct Mechanical Measurements of the Elasticity of Single DNA Molecules by Using Magnetic Beads
Smith, S. B., Finzi, L., & Bustamante, C. (1992) · Science · doi:10.1126/science.1439819 · Cited by 1,817
Green, N. M. (1975) · Advances in Protein Chemistry · doi:10.1016/s0065-3233(08)60411-8 · Cited by 1,458
Imaging Crystals, Polymers, and Processes in Water with the Atomic Force Microscope
Drake, B., Prater, C. B., Weisenhorn, A. L., Gould, S. A. C., Albrecht, T. R., Quate, C. F., Cannell, D. S., Hansma, H. G., & Hansma, P. K. (1989) · Science · doi:10.1126/science.2928794 · Cited by 1,033
Conformational Substates in Proteins
Frauenfelder, H., Parak, F., & Young, R. D. (1988) · Annual Review of Biophysics and Biophysical Chemistry · doi:10.1146/annurev.bb.17.060188.002315 · Cited by 993
From Molecules to Cells: Imaging Soft Samples with the Atomic Force Microscope
Radmacher, M., Tillmann, R. W., Fritz, M., & Gaub, H. E. (1992) · Science · doi:10.1126/science.1411505 · Cited by 900
Self-citationSensing Discrete Streptavidin-Biotin Interactions with Atomic Force Microscopy
Lee, G. U., Kidwell, D. A., & Colton, R. J. (1994) · Langmuir · doi:10.1021/la00014a003 · Cited by 702
Three-dimensional structures of avidin and the avidin-biotin complex.
Livnah, O., Bayer, E. A., Wilchek, M., & Sussman, J. L. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.11.5076 · Cited by 652
Force of Single Kinesin Molecules Measured with Optical Tweezers
Kuo, S. C., & Sheetz, M. P. (1993) · Science · doi:10.1126/science.8469975 · Cited by 424
Darst, S. A., Ahlers, M., Meller, P. H., Kubalek, E. W., Blankenburg, R., Ribi, H. O., Ringsdorf, H., & Kornberg, R. D. (1991) · Biophysical Journal · doi:10.1016/s0006-3495(91)82232-9 · Cited by 339
Binomial smoothing filter: A way to avoid some pitfalls of least-squares polynomial smoothing
Marchand, P., & Marmet, L. (1983) · Review of Scientific Instruments · doi:10.1063/1.1137498 · Cited by 261
Measurement of ligand-receptor interactions.
Helm, C. A., Knoll, W., & Israelachvili, J. N. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.18.8169 · Cited by 170
Karrasch, S., Dolder, M., Schabert, F., Ramsden, J., & Engel, A. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81327-4 · Cited by 163
Synthetic lipid-anchored receptors based on the binding site of a monoclonal antibody
Egger, M., Heyn, S. P., & Gaub, H. E. (1992) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(92)90130-e · Cited by 28
Self-citation
Cited by
Synthesis and surface engineering of iron oxide nanoparticles for biomedical applications
Gupta, A. K., & Gupta, M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.10.012 · Cited by 6,771
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 3,709
Dynamic strength of molecular adhesion bonds
Evans, E., & Ritchie, K. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78802-7 · Cited by 2,549
Single-molecule force spectroscopy: optical tweezers, magnetic tweezers and atomic force microscopy
Neuman, K. C., & Nagy, A. (2008) · Nature Methods · doi:10.1038/nmeth.1218 · Cited by 2,406
Dynamic atomic force microscopy methods
García, R. (2002) · Surface Science Reports · doi:10.1016/s0167-5729(02)00077-8 · Cited by 2,076
Metadata
- Authors
- Florin, E.-L., Moy, V. T., & Gaub, H. E.
- Venue
- Science
- Published
- 1994-04-15
- Volume
- 264
- Issue
- 5157
- Pages
- 415-417
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1985900564
- Cited by
- 1,903
- References
- 18
- FWCI
- 36.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.