Recalibrating global data center energy-use estimates
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Growth in energy use has slowed owing to efficiency gains that smart policies can help maintain in the near term
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, the sustainability benefits of cloud computing are not automatic and depend on a range of factors, including the energy efficiency of the underlying data centers, the carbon intensity of the electricity grid, and the optimization of workload placement and resource allocation [15].”
From The evolution of green computing: Current practices and societal implications (2024) · cites this paper as [15]
In the citing paper
“accounting for an estimated 1% of global electricity consumption and 0.3% of global carbon emissions [15].”
From The evolution of green computing: Current practices and societal implications (2024) · cites this paper as [15]
In the citing paper
“This can lead to significant energy savings compared to traditional on-premises IT infrastructures, which often suffer from low utilization rates and inefficient resource management.”
From The evolution of green computing: Current practices and societal implications (2024) · cites this paper as [15]
In the citing paper
“Masanet et al.11 reported that data centers' operational energy consumption has increased only marginally from 194 TWh in 2010 to 205 TWh in 2020 despite global data center compute instances increasing by 550% over the same time period—showing the effectiveness of efficiency improvements in ICT.”
From The real climate and transformative impact of ICT: A critique of estimates, trends, and regulations (2021) · cites this paper as Masanet et al.11
In the citing paper
“The methodology and assumptions behind Mora et al.’s70 projections of blockchain's future energy use have been questioned by Masanet et al.,11 but proof of work is widely accepted to be energy-intensive.”
From The real climate and transformative impact of ICT: A critique of estimates, trends, and regulations (2021) · cites this paper as [11]
4 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
On Global Electricity Usage of Communication Technology: Trends to 2030
Andrae, A., & Edler, T. (2015) · Challenges · doi:10.3390/challe6010117 · Cited by 1,334
How to stop data centres from gobbling up the world’s electricity
Jones, N. (2018) · Nature · doi:10.1038/d41586-018-06610-y · Cited by 1,166
United States Data Center Energy Usage Report
Lawrence Berkeley National Laboratory (LBNL), B., Shehabi, A., USDOE, Smith, S., Sartor, D., Brown, R., Herrlin, M., Koomey, J., Masanet, E., Horner, N., et al. (2016) · doi:10.2172/1372902 · Cited by 1,040 · cited 5×
“In a series of reports starting in 2016, Lawrence Berkeley National Laboratory has published energy trend analyses of servers, storage devices, and network devices commonly used within data centers (8, 11, 13).”
BackgroundInfluentialSelf-citationWorldwide electricity used in data centers
Koomey, J. G. (2008) · Environmental Research Letters · doi:10.1088/1748-9326/3/3/034008 · Cited by 972
Self-citationAssessing ICT global emissions footprint: Trends to 2040 & recommendations
Belkhir, L., & Elmeligi, A. (2018) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2017.12.239 · Cited by 970
Ohno, K. (2021) · Journal of the Atomic Energy Society of Japan · doi:10.3327/jaesjb.63.3_283 · Cited by 376
Avgerinou, M., Bertoldi, P., & Castellazzi, L. (2017) · Energies · doi:10.3390/en10101470 · Cited by 363
Data center growth in the United States: decoupling the demand for services from electricity use
Shehabi, A., Smith, S. J., Masanet, E., & Koomey, J. (2018) · Environmental Research Letters · doi:10.1088/1748-9326/aaec9c · Cited by 189
Self-citationEstimating the Energy Use and Efficiency Potential of U.S. Data Centers
Masanet, E. R., Brown, R. E., Shehabi, A., Koomey, J. G., & Nordman, B. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2155610 · Cited by 87
Self-citationCharacteristics of low-carbon data centres
Masanet, E. R., Shehabi, A., & Koomey, J. (2013) · Nature Climate Change · doi:10.1038/nclimate1786 · Cited by 84
Self-citation
Research works printed but not linked: 5
- Cisco, “Cisco Global Cloud Index: Forecast and methodology, 2016–2021 white paper” (Cisco, document 1513879861264127, 2018).
- J. G. Koomey, “Growth in data center electricity use 2005 to 2010” (Analytics Press for the New York Times, 2011).
- B. Wagner, “Intergenerational energy efficiency of Dell EMC PowerEdge servers” (Dell, DellEMC white paper, 2018).
- IEA, “Tracking clean energy progress” (IEA, 2019); www.iea.org/tcep/.
- H. Fuchs . Energy Effic. 10.1007/s12053-019-09809-8 (2019). · DOI
Cited by
Items 801–900 of 1,007
Liu, M., Song, P., Yang, Q., Deng, S., & Zhu, Z. (2025) · Sustainable Energy Technologies and Assessments · doi:10.1016/j.seta.2025.104661 · Cited by 2
HRB: A backfilling algorithm for heterogeneous clusters with job prioritization
Palacios, J., Stafford, E., & Bosque, J. L. (2025) · Future Generation Computer Systems · doi:10.1016/j.future.2025.108309 · Cited by 2
Ruiu, M. L., Ruiu, G., Ragnedda, M., & Addeo, F. (2026) · Journal of Information Communication and Ethics in Society · doi:10.1108/jices-04-2025-0094 · Cited by 2
Carbon emissions flow and inequality embodied in cross-regional computility transfer in China
Zhou, K., Yang, Z., Lu, X., & Hu, R. (2026) · Humanities and Social Sciences Communications · doi:10.1057/s41599-025-06431-1 · Cited by 3
MetaFed: Advancing Privacy, Performance, and Sustainability in Federated Metaverse Systems
Yagiz, M. A., Cengiz, Z. S., & Göktaş, P. (2025) · IEEE International Symposium on Emerging Metaverse (ISEMV) · doi:10.1109/isemv67326.2025.00031 · Cited by 2
“Third, the environmental impact of these infrastructures is non-trivial; data centers are already responsible for 3–4% of global electricity 1 Available at: https://github.com/afrilab/MetaFed-FL use, with projections showing further escalation driven by artificial intelligence (AI) and XR [8], [9].”
Liu, L., Luo, C., Xie, Z., Tian, Z., Pi, P., Wang, S., Wen, X., & Shan, J. (2026) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5c20167 · Cited by 2
Carbon-Aware Scheduling and Distributionally Robust Optimization for Cloud Systems
Ruparel, H. (2025) · IEEE International Conference on Cloud Computing Technology and Science · doi:10.1109/cloudcom67567.2025.11331352 · Cited by 3
“Recent studies estimate that data centers and data transmission networks account for roughly 1–1.5% of global electricity use and about 1% of greenhouse gas (GHG) emissions [1], [2].”
InfluentialImproved superhydrophobic surface for new phase-change thermal diode in building thermal management
Zhao, H., Li, S., Wu, Y., Sun, H., & Lin, B. (2026) · Energy · doi:10.1016/j.energy.2026.140161 · Cited by 2
Sustainability In Large-Scale Cloud Operations: AI For Carbon Control
Palaniappan, S. (2026) · Journal of International Crisis and Risk Communication Research · doi:10.63278/jicrcr.vi.3621 · Cited by 2
From deep archival to real-time applications: Challenges and opportunities in DNA data storage
Liu, Q., Liu, Q.-J., Kang, S., Li, J., Xia, H., & Qi, H. (2026) · Biotechnology Advances · doi:10.1016/j.biotechadv.2026.108833 · Cited by 3
Pinto, R. C., Brockway, P. E., Domingos, T., & Sousa, T. (2026) · iScience · doi:10.1016/j.isci.2026.114876 · Cited by 3
“Regarding servers’ hours of use, we assume that servers work 24 h per day every day, based on Masanet et al., 11 while Hilbert and Lope´ z 34 assume only 8 h per day, which explains almost completely the differences in computed information for 1993 and 2000.”
Nonlinear optical extreme learner via data reverberation with incoherent light
Liu, B., Mei, X., Shafi, S., Xia, T., Khoo, I. C., Liu, Z., & Ni, X. (2026) · Science Advances · doi:10.1126/sciadv.aeb4237 · Cited by 6
Ahmadi, L., Baktash, I., Moghaddam, H. H., Heidari, R., Alhosseini, S., & Zahedi, R. (2026) · Case Studies in Thermal Engineering · doi:10.1016/j.csite.2026.107826 · Cited by 2
Tsai, A. (2026) · Pediatric Radiology · doi:10.1007/s00247-026-06553-x · Cited by 3
A self-assessment framework for evaluating efficiency of data centers
Kuzay, M., Demirel, E., Bayraktar, B., Vilestad, J., Kärnebro, A., Yilmaz, C., Melgaard, S. P., Juul, T., Nielsen, J. E., Fricker, R., et al. (2026) · Energy Informatics · doi:10.1186/s42162-026-00652-7 · Cited by 2
Evaluating internet accessibility and equity in Indonesia using integrated SUSENAS and OOKLA data
Caraka, R. E., Supardi, K., Kaban, P. A., Gio, P. U., Prakasa, E., Isnaniawardhani, V., Putri, R. L., Lukas, A., Risdianto, D. Y., Chen, R. C., et al. (2026) · Discover Sustainability · doi:10.1007/s43621-026-02882-x · Cited by 2
Study and analysis of runtime energy consumption in cellular 5G network: an empirical approach
Uitto, M., Mäkelä, J., Apilo, O., Rantala, S. J., Pinola, J., & Gupta, N. (2026) · Journal on Wireless Communications and Networking · doi:10.1186/s13638-026-02598-6 · Cited by 2
Machado, A. L. S., & Marreiros, M. G. (2026) · Discover Sustainability · doi:10.1007/s43621-026-02847-0 · Cited by 3
Furberg, A., & Finnveden, G. (2026) · Environmental Impact Assessment Review · doi:10.1016/j.eiar.2026.108445 · Cited by 2
Khalil, H. M., Elrefaiy, A., Elbaz, M., & Loey, M. (2026) · Scientific Reports · doi:10.1038/s41598-026-46375-3 · Cited by 2
Zhao, R., Hu, J., Sun, Y., Yang, H., Yu, H., Zhao, C., Wang, Q., Li, Z., Duan, F., Yang, C., et al. (2026) · Energy and Buildings · doi:10.1016/j.enbuild.2026.117535 · Cited by 2
Sultana, N., Haque, A., & Rupa, R. A. (2026) · Administrative Sciences · doi:10.3390/admsci16050215 · Cited by 3
Jones, E., & Jones, E. (2026) · Electricity · doi:10.3390/electricity7020043 · Cited by 2
“Historically, landmark studies [3,4] demonstrated that data centers maintained a relatively flat global energy footprint despite growing compute demand, owing to efficiency gains in hyperscale architecture and server utilization.”
Johnson, J. X., Wade, C., Blackhurst, M. F., DeCarolis, J. F., de Queiroz, A. R., Posen, I. D., & Jaramillo, P. (2026) · Environmental Research Letters · doi:10.1088/1748-9326/ae6c3d · Cited by 4
“Bottom-up approaches to estimate data center energy use detailed data on equipment and operations (e.g. [4, 25]), while top-down models draw on aggregated energy statistics [26] and extrapolation meth-ods project future energy use by applying growth rates [27].”
Zhang, Y., Han, X., Wu, X., Tang, T., Jiang, X., & Yan, J. (2026) · Energy · doi:10.1016/j.energy.2026.141426 · Cited by 2
Zhang, Z., & Liu, Z. (2026) · Sustainability · doi:10.3390/su18115383 · Cited by 2
Dai, Y., & Meng, Z. (2026) · Sustainability · doi:10.3390/su18115546 · Cited by 2
Tuersun, Y., Luo, W., Zhao, J., Li, B., & Zhu, G. (2026) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6c04094 · Cited by 2
Public perceptions of AI energy consumption: Awareness, responsibility attribution, and strategies
Klesel, M., & Messer, U. (2026) · Electronic Markets · doi:10.1007/s12525-026-00908-w · Cited by 2
“The deployment of GenAI demands a vast amount of resources, which increasingly strains energy supplies (see, e.g., Masanet et al., 2020; Ananthaswamy, 2023).”
Zarea, H., Shirkoohi, S. M., Ertz, M., & Hessas, D. (2026) · Economies · doi:10.3390/economies14070255 · Cited by 2
Chen, D., Fu, Y., Tan, M. K. H., Ye, L., Chui, C., & Lee, P.-S. (2026) · Applied Energy · doi:10.1016/j.apenergy.2026.128414 · Cited by 2
Alves, D. S., & Conceição, M. M. (2026) · Revista Científica SOL21 - Standard Open Literature · doi:10.67553/sol21.v2i1.29 · Cited by 2
From Scroll to Screen: Cultural Memory in Transition
Khatoon, R. (2026) · International Journal of Humanities Social Sciences and Development Studies (IJHSD) · doi:10.68219/kkdye964 · Cited by 2
One Quarter of Global Data Centers are Located in Water-Stressed Areas
Rosa, L., Sangiorgio, M., Scanlon, B. R., Mazzotti, M., Berry, J. A., & Michalak, A. M. (2026) · Environmental Science & Technology · doi:10.1021/acs.est.6c08088 · Cited by 3
Ge, Y., Zhang, W., Li, H., & Xie, Z. (2023) · International Journal of Emerging Electric Power Systems · doi:10.1515/ijeeps-2023-0092 · Cited by 3
INGR Roadmap Energy Efficiency Chapter
Zahnstecher, B., Carobolante, F., McCune, E., Gerber, D., Kirkpatrick, D., Olsson, M., Booth, R., Björnson, E., Bresniker, K., Draxler, P. J., et al. (2023) · IEEE Future Networks World Forum (FNWF) · doi:10.1109/fnwf58287.2023.10520551 · Cited by 2
VLC-FBMC Enabled Optical Wireless Data Centers
Srivastava, M. K., Shukla, M. K., & Singh, A. K. (2024) · Wireless Personal Communications · doi:10.1007/s11277-024-11330-w · Cited by 2
“1), improve flexibility and scalability, and reduce maintenance costs and energy consumption [2].”
Building a Greener Future : The Role of Data Centers in Eco-Friendly Computing
-, S. C., Srirangam, R. K., & Pendyala, V. (2024) · International Journal of Scientific Research in Computer Science Engineering and Information Technology · doi:10.32628/cseit241051021 · Cited by 2
S-ORCA: A Social-Based Consolidation Approach to Reduce Cloud Infrastructures Energy Consumption
Lambert, S., Caron, E., Lefèvre, L., & Grivel, R. (2024) · IEEE International Conference on Cloud Computing Technology and Science · doi:10.1109/cloudcom62794.2024.00030 · Cited by 2
“But the growth is DCs power consumption did not follow the same trend as the total amount of compute instances and supported workloads [19].”
GenAI: Unlocking Sustainability Insights and Driving Change in Fintech
Gopal, S., & Pitts, J. (2024) · Sustainable finance · doi:10.1007/978-3-031-74418-1_9 · Cited by 4
Silicon is Greener: Why Innovation in Circuits is Needed for Sustainability
Lloyd, J., Kearney, N., Lyden, C., McCartney, D., Robertson, D. H., & Shine, M. (2020) · Symposium on VLSI Technology · doi:10.1109/vlsitechnology18217.2020.9265102 · Cited by 2
“Data centers have quickly grown to be a large consumer of energy on the grid, over 60 B kWh per year in the United States alone [16].”
BackgroundCharan, B., Goutham, K. S., Mampilli, R. J., Kempaiah, B. U., & Phalachandra, H. L. (2021) · International Conference on Intelligent Technologies (CONIT) · doi:10.1109/conit51480.2021.9498421 · Cited by 2
Terenius, P., Garraghan, P., & Harper, R. H. R. (2021) · Journal of Strategic Innovation and Sustainability · doi:10.33423/jsis.v16i2.4297 · Cited by 2
“(Masanet et al., 2020; Mujawar et al., 2018) This energy, primarily used by”
Coupled Calculations of Data Center Cooling and Power Distribution Systems
Wemhoff, A. P., & Ahmed, F. (2021) · Journal of Electronic Packaging · doi:10.1115/1.4052101 · Cited by 2
On the energy consumption of online and on-site lectures
Holas, A., Koch, C. Y., Leibold, J. P., Prendi, A., Schlachta, T. P., Schmid, A. S., & Schmitt, L. (2022) · Environmental Research Communications · doi:10.1088/2515-7620/ac77df · Cited by 3
Multiphysics Thermal-Acoustic Modeling of a Server in a Data Center
Nagrani, P. P., Alfoqaha, A., Demetriou, D. W., & Bard, S. (2022) · I-THERM :/I-THERM - Intersociety Conference on Thermal Phenomena in Electronic Systems · doi:10.1109/itherm54085.2022.9899616 · Cited by 2
“One recent study estimated that global data center energy use rose to 205 TWh; however, this represented only a 6% increase since 2010, despite a 550% increase in the number of deployed compute instances [2].”
BackgroundINGR Roadmap Energy Efficiency Chapter
Zahnstecher, B., McCune, E., Kirkpatrick, D., Booth, R., Bresniker, K., Nease, L., Bandyopadhyay, A., Bruce Nordman, B., Carobolante, F., Olsson, M., et al. (2022) · IEEE Future Networks World Forum (FNWF) · doi:10.1109/fnwf55208.2022.00137 · Cited by 2
pHPCe: a hybrid power conservation approach for containerized HPC environment
Kuity, A., & Peddoju, S. K. (2023) · Cluster Computing · doi:10.1007/s10586-023-04105-8 · Cited by 2
“Environmental Protection Agency (EPA) [1] reported that the worldwide data centers consume 220-320 Tera Watt hours (TWh) of electricity in 2021, amounting to 0.9 (cid”
InfluentialEnergy-Efficient Integrated Photonics for Future Optical Interconnects and Neuromorphic Computing
Cheung, S. S., Liang, D., Tossoun, B. M., Yuan, Y., Kurczveil, G., Hu, Y., Descos, A., Peng, Y., Srinivasan, S., & Beausoleil, R. G. (2023) · IEEE CPMT Symposium Japan (ICSJ) · doi:10.1109/icsj59341.2023.10339591 · Cited by 2
Efficient Fiber-Inspection Method for Optical-Circuit Datacenter Networks
Anazawa, K., Inoue, T., Mano, T., Ishida, W., Obana, K., & Nishizawa, H. (2023) · Globecom · doi:10.1109/globecom54140.2023.10437204 · Cited by 2
Technologies and innovative solutions for sustainable data centers
Gloukhovtsev, M. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-13597-2.00003-0 · Cited by 3
Jiang, H., Li, Z., & Bai, X. (2024) · Energy and Buildings · doi:10.1016/j.enbuild.2024.114504 · Cited by 2
Zhao, J., Xia, Y., Sun, X., Long, T., Peng, Q., Guo, S., Meng, F., Dong, Y., & Xia, Q. (2024) · Wireless Networks · doi:10.1007/s11276-024-03820-3 · Cited by 2
“Consequently, the substantial rise in energy costs has become an exceed-ingly challenging issue [3].”
Towards a Framework for Carbon-Aware Virtual Machine Management
Pathania, P., Mehra, R., Sikand, S., Sharma, V. S., Kaulgud, V., Bamby, N., Podder, S., & Burden, A. P. (2024) · IEEE International Conference on Software Architecture Companion (ICSA-C) · doi:10.1109/icsa-c63560.2024.00052 · Cited by 2
“Moreover, the data center energy use has doubled in the last decade and is expected to triple in the coming decade [2].”
BackgroundUnveiling Key Performance Indicators for the Energy Efficiency of Cloud Data Storage
Banijamali, P., Fatima, I., Lago, P., & Heitlager, I. (2024) · IEEE International Conference on Software Architecture Companion (ICSA-C) · doi:10.1109/icsa-c63560.2024.00047 · Cited by 3
Serengil, S. I., & Ozpinar, A. (2024) · Symmetry · doi:10.3390/sym18050832 · Cited by 6
Application-Independent DVFS Method Based on OS Metrics Monitoring for Cloud Servers
Noguchi, H., & KANEKO, M. (2024) · International Conference on Communications, Computing, Cybersecurity, and Informatics (CCCI) · doi:10.1109/ccci61916.2024.10736461 · Cited by 2
“Since servers account for a large proportion of power consumption in data centers [2-3], saving server power is one of the most effective approaches to reduce power consumption.”
BackgroundAccelerating tensor multiplication by exploring hybrid product with hardware and software co-design
Zhang, Z., Fan, Z., Li, W., Qiu, Y., Wang, Z., Ye, X., Fan, D., & An, X. (2025) · Journal of Systems Architecture · doi:10.1016/j.sysarc.2025.103333 · Cited by 2
Unlocking Indonesia's Data Center Potential: Location Advantage and Cost Efficiency
Sebastian, A. (2024) · Dinasti International Journal of Education Management And Social Science · doi:10.38035/dijemss.v5i5.2804 · Cited by 2
A systematic mapping study on software approaches analyzing human behavior in energy efficiency
Zaragoza, T., Noureddine, A., & Expósito, E. (2025) · Energy Research & Social Science · doi:10.1016/j.erss.2025.103991 · Cited by 2
Impact of magnetic ion substitution on the crystal structure of multiferroic Aurivillius phases
Halpin, J., Schmidt, M., Whatmore, R. W., & Keeney, L. (2025) · APL Electronic Devices · doi:10.1063/5.0246803 · Cited by 2
Cloud Computing: Innovations and Impacts on Global Data Infrastructure
Banumathi, S., Sivajothi, E., Indumathi.G., S., Kefyalew, E. Y., Sivakumar, J., & Priya, V. B. (2025) · International Conference on Computational, Communication and Information Technology (ICCCIT) · doi:10.1109/icccit62592.2025.10927743 · Cited by 2
“There has also been a rise in interest in "green computing" and the effects of cloud data centers on the environment [13].”
Chen, L., Li, X., Wang, K., & Yu, X. (2025) · IEEE Data Driven Control and Learning Systems Conference (DDCLS) · doi:10.1109/ddcls66240.2025.11065957 · Cited by 3
“Globally, data centers account for 1% of energy use, underscoring efficiency optimization needs[3].”
Machine Learning-Based GPU Energy Prediction for Workload Management in Datacenters
Ismalej, B., Smith, M., & Jiang, X. (2025) · IEEE Annual Computing and Communication Workshop and Conference (CCWC) · doi:10.1109/ccwc62904.2025.10903830 · Cited by 2
“Due to their rapid rise in demand and their intensity in energy consumption, they account for approximately 1 % of worldwide energy consumption [1].”
Keleher, A., Dargusch, P., & Hill, G. (2022) · Advances in Environmental and Engineering Research · doi:10.21926/aeer.2202013 · Cited by 5
Two-phase modeling for porous micro-channel evaporators
Mendizabal, J. K., Amalfi, R. L., & Enright, R. (2022) · I-THERM :/I-THERM - Intersociety Conference on Thermal Phenomena in Electronic Systems · doi:10.1109/itherm54085.2022.9899638 · Cited by 4
“Considering that global DC electrical energy consumption was 200 TWh in 2010 [10], while the global energy consumption by buildings for space/water heating was 17.”
BackgroundOstapenco, V., Lefèvre, L., Orgerie, A., & Fichel, B. (2023) · The International Journal of High Performance Computing Applications · doi:10.1177/10943420231172978 · Cited by 5
“Even if some studies suggest some flat energy consumption of worldwide data centers over the last decade Masanet et al. (2020), some exhaustive review exhibit more contrasted results Mytton and Ashtine (2022).”
BackgroundResultWang, X., Yang, J., Wen, Q., Xiang, J., Shittu, S., Zhao, X., & Wang, Z. (2023) · International Journal of Green Energy · doi:10.1080/15435075.2023.2196335 · Cited by 2
“According to survey statistics, in 2018, the electricity consumption of global DC was about 205 TWh, accounted for 1% of the world electricity consumption, which represented a 6% increase compared with 2010 (Haddad et al. 2021; Masanet et al. 2020).”
Energy‐efficient load balancing for divisible tasks on heterogeneous clusters
Zhang, Y., Li, M., & Tong, F. (2023) · Transactions on Emerging Telecommunications Technologies · doi:10.1002/ett.4829 · Cited by 2
“More formally, the problem studied in this article can be formulated as a nonlinear program by subject to: where o i is a binary value that denotes the “on/off” status of server S i with 1 indicates “on” while 0 indicates “off,” as shown in Equation (7).”
BackgroundInfluentialFuture: The Foreseeable Development of AI
Floridi, L. (2023) · Oxford University Press eBooks · doi:10.1093/oso/9780198883098.003.0003 · Cited by 2
AI and the UN Sustainable Development Goals
Floridi, L. (2023) · Oxford University Press eBooks · doi:10.1093/oso/9780198883098.003.0012 · Cited by 2
A Network Topology for Composable Infrastructures
Ajibola, O. O., El-Gorashi, T. E. H., & Elmirghani, J. M. H. (2020) · International Conference on Transparent Optical Networks · doi:10.1109/icton51198.2020.9203275 · Cited by 2
“Between 2010 and 2018, the volume of compute instances in datacentres (DCs) increased by over 500% [1].”
BackgroundKosuke, S., Aoki, T., Komatsu, M., & Watanabe, T. (2020) · Energies · doi:10.3390/en13195222 · Cited by 3
Santos, A. F., Gaspar, P. D., & de Souza, H. J. L. (2021) · Applied Sciences · doi:10.3390/app11135950 · Cited by 2
“Growth of global data center instances [2].”
BackgroundSoftware-Defined Power Supply to Geo-Distributed Edge DCs
Tang, G., Guo, D., & Wu, K. (2022) · SpringerBriefs in computer science · doi:10.1007/978-981-16-9690-9_6 · Cited by 2
Les certificats de sobriété numérique comme instrument de régulation de la pollution numérique
Nicolaï, J., & Peragin, L. (2022) · Revue de l'OFCE/La Revue de l'OFCE · doi:10.3917/reof.176.0229 · Cited by 4
Battaglioli, S., Lebon, M., Jenkins, R., Summers, J. L., Sarkinen, J., & Robinson, A. J. (2022) · International Workshop on Thermal Investigations of ICs and Systems · doi:10.1109/therminic57263.2022.9950635 · Cited by 2
Environmental Impact of Robotics: Ethical Concerns and Legal Alternatives
Ó’Brolcháin, F., & Ruiz, M. A. G. (2020) · Encyclopedia of the UN sustainable development goals · doi:10.1007/978-3-319-71059-4_147-1 · Cited by 2
From Average to Marginal: Estimating Emission Factors in Europe's Electricity MarketsPreprint
Brander, M., Haxhimusa, A., Liebensteiner, M., & Taschini, L. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5212648 · Cited by 2
Green Computing: The Ultimate Carbon Destroyer for a Sustainable FuturePreprint
Amiri, S. M. H., GOSWAMI, P., Islam, M. M., Hossen, M. S., Mithila, M., & Akter, N. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5382837 · Cited by 4
Efficient and privacy-preserving compressive learning
Chatalic, A. (2020) · theses.fr (ABES) · doi:10.70675/32098958z1deez4f21zb51az429b616621fd · Cited by 4
A Novel Multiscale Evaluation Metric for the Thermal Management of Data Centers
Zhu, J., & Zhang, K. (2022) · Journal of Thermal Science and Engineering Applications · doi:10.1115/1.4055745 · Cited by 1
Data Center e Eficiência Energética
de Brito, J. L. R., Matai, P. H. L. D. S., & dos Santos, M. R. (2023) · Brazilian Journal of Business · doi:10.34140/bjbv5n2-002 · Cited by 1
Belkin, S. (2023) · Annual IEEE Semiconductor Thermal Measurement and Management Symposium/Proceedings · doi:10.23919/semi-therm59981.2023.10267885 · Cited by 1
Energy-Saving Practice of Variable Frequency Drive Technology in Data Center HVAC System
Ai, C., Yang, J., & Chen, R. (2023) · International Conference on Power and Energy Technology (ICPET) · doi:10.1109/icpet59380.2023.10367206 · Cited by 1
“Consequently, many researchers have focused on optimising the energy consumption of the ventilation and pumping systems of the HVAC system as a means of achieving energy efficiency in data centres [2] – [7].”
BackgroundPerformance Prediction Based Workload Scheduling in Co-Located Cluster
Ou, D., Ren, Y., & Jiang, C. (2024) · Computer Modeling in Engineering & Sciences · doi:10.32604/cmes.2023.029987 · Cited by 1
Climate impacts of digital use supply chains
Shi, L., Brandt, A. R., Iancu, D. A., Mach, K. J., Field, C. B., Cho, M.-J., Ng, M., Chey, K. J., Ram, N., Robinson, T. N., et al. (2024) · Environmental Research Climate · doi:10.1088/2752-5295/ad22eb · Cited by 1
Zhou, Y., Wang, Q., & Li, G. (2024) · International Conference on Science, Engineering and Technology Practices for Sustainable Development (ICSETPSD) · doi:10.4108/eai.17-11-2023.2342625 · Cited by 1
Mastroianni, M., Ficco, M., Palmieri, F., & Martone, V. E. (2024) · Lecture notes on data engineering and communications technologies · doi:10.1007/978-3-031-53555-0_17 · Cited by 1
Thanavanich, T., Kantawong, K., Yaibuates, M., Duangtang, P., Siri, A., & Sriwanna, K. (2024) · Joint International Conference on Digital Arts, Media and Technology with ECTI Northern Section Conference on Electrical, Electronics, Computer and Telecommunications Engineering (ECTI DAMT & NCON) · doi:10.1109/ectidamtncon60518.2024.10480095 · Cited by 1
“Estimations indicate that energy consumption in computing doubles every ten years [1].”
BackgroundThe Brazilian Practices for Handling Sustainability in Software Engineering: a Replicated Survey
Melo, R., Vilela, J., Silva, C., Peixoto, M., & Araújo, J. (2024) · Brazilian Symposium on Software Quality (SBQS) · doi:10.1145/3701625.3701668 · Cited by 3
“Furthermore, the energy demand for power data centers worldwide is expected to triple in the coming years [16].”
Data Center Resource Usage Forecasting with Convolutional Recurrent Neural Networks
Malin, M., & Suutala, J. (2025) · Linköping electronic conference proceedings · doi:10.3384/ecp212.061 · Cited by 2
Manchikanti, D. R. (2025) · International Journal of Scientific Research in Computer Science Engineering and Information Technology · doi:10.32628/cseit251112147 · Cited by 1
SAT-GAV: A Electricity-Costs Aware Resources Placement Strategy for Data Centers
Feng, H., Xu, X., Chen, L., & Li, J. (2024) · IEEE International Symposium on Parallel and Distributed Processing with Applications (ISPA) · doi:10.1109/ispa63168.2024.00195 · Cited by 1
“This study differs from prior work [11], [12] by focusing on minimizing global electricity costs through task scheduling and virtual machine placement (VMP).”
Altahat, M. A., Mhaidat, K. M., & Al-Khaleel, O. D. (2025) · Simulation Modelling Practice and Theory · doi:10.1016/j.simpat.2025.103102 · Cited by 1
Spatiotemporal Task Scheduling for Green Computing in Computing Power Networks
Wen, W., Xie, R., Tang, Q., Xiong, Z., Xie, G., & Huang, T. (2024) · Globecom · doi:10.1109/globecom52923.2024.10901134 · Cited by 1
Technology and Applications of Compiler-Based Precision Tuning
Cattaneo, D. (2025) · SpringerBriefs in applied sciences and technology · doi:10.1007/978-3-031-80268-3_3 · Cited by 1
Kamalakannan, N. K., Shariff, K. S. R., & Haider, U. (2024) · IEEE/ACM International Conference on Utility and Cloud Computing (UCC) · doi:10.1109/ucc63386.2024.00030 · Cited by 1
“Terraform ensures consistent deployment through an Infrastructure as Code approach, with integrations for AWS CLI to manage instances [9].”
Lee, M., Min, S., Kim, G., & Lee, S. (2025) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3706598.3713144 · Cited by 2
“…to addressing the energy consumption of digital infrastructures can be taken by 1) improving the efficiency of the underlying infrastructure [42, 48], 2) making algorithms and architectures more energy efficient [35, 44, 59], or 3) applying sustainable interaction design to digital…”
Bourgeois, G., Angulo, G., Elzein, H., Courboulay, V., & Cheriet, M. (2025) · Springer eBooks · doi:10.1007/978-3-031-82896-6_9 · Cited by 1
Metadata
- Authors
- Masanet, E., Shehabi, A., Lei, N., Smith, S., & Koomey, J.
- Affiliations
- Northwestern University (US)
- Lawrence Berkeley National Laboratory (US)
- Koomey Analytics, Burlingame, CA, USA.
- Venue
- Science
- Published
- 2020-02-28
- Volume
- 367
- Issue
- 6481
- Pages
- 984-986
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W3007855629
- Cited by
- 1,545
- References
- 11
- Citations by year
- 2026: 429 · 2025: 287 · 2024: 222 · 2023: 267 · 2022: 158 · 2021: 145 · 2020: 36
- FWCI
- 51.94
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Science (publishedVersion)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Green IT and Sustainability
- Physical Sciences › Computer Science › Hardware and Architecture › Energy Efficiency in Computing
- Physical Sciences › Computer Science › Information Systems › Cloud Computing and Resource Management
- Keywords
- data center energy consumption, global energy consumption, energy efficiency, energy policy, energy demand growth
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.