Metabolite-induced in vivo fabrication of substrate-free organic bioelectronics
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Interfacing electronics with neural tissue is crucial for understanding complex biological functions, but conventional bioelectronics consist of rigid electrodes fundamentally incompatible with living systems. The difference between static solid-state electronics and dynamic biological matter makes seamless integration of the two challenging. To address this incompatibility, we developed a method to dynamically create soft substrate-free conducting materials within the biological environment. We demonstrate in vivo electrode formation in zebrafish and leech models, using endogenous metabolites to trigger enzymatic polymerization of organic precursors within an injectable gel, thereby forming conducting polymer gels with long-range conductivity. This approach can be used to target specific biological substructures and is suitable for nerve stimulation, paving the way for fully integrated, in vivo–fabricated electronics within the nervous system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular dynamics with coupling to an external bath
Berendsen, H. J. C., Postma, J. P. M., van Gunsteren, W. F., DiNola, A., & Haak, J. R. (1984) · The Journal of Chemical Physics · doi:10.1063/1.448118 · Cited by 30,700
Canonical dynamics: Equilibrium phase-space distributions
Hoover, W. G. (1985) · Physical Review A · doi:10.1103/physreva.31.1695 · Cited by 23,465
Polymorphic transitions in single crystals: A new molecular dynamics method
Parrinello, M., & Rahman, A. (1981) · Journal of Applied Physics · doi:10.1063/1.328693 · Cited by 19,790
Canonical sampling through velocity rescaling
Bussi, G., Donadio, D., & Parrinello, M. (2007) · The Journal of Chemical Physics · doi:10.1063/1.2408420 · Cited by 18,089
Hehre, W. J., Ditchfield, R., & Pople, J. A. (1972) · The Journal of Chemical Physics · doi:10.1063/1.1677527 · Cited by 15,855
Automatic atom type and bond type perception in molecular mechanical calculations
Wang, J., Wang, W., Kollman, P. A., & Case, D. A. (2006) · Journal of Molecular Graphics and Modelling · doi:10.1016/j.jmgm.2005.12.005 · Cited by 5,477
Density Functional Theory of Electronic Structure
Kohn, W., Becke, A. D., & Parr, R. G. (1996) · The Journal of Physical Chemistry · doi:10.1021/jp960669l · Cited by 3,461
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Towards a Comprehensive Catalog of Zebrafish Behavior 1.0 and Beyond
Kalueff, A. V., Gebhardt, M., Stewart, A. M., Cachat, J. M., Brimmer, M., Chawla, J. S., Craddock, C., Kyzar, E. J., Roth, A., Landsman, S., et al. (2013) · Zebrafish · doi:10.1089/zeb.2012.0861 · Cited by 1,061
Electrical bioadhesive interface for bioelectronics
Deng, J., Yuk, H., Wu, J., Varela, C. E., Chen, X., Roche, E. T., Guo, C. F., & Zhao, X. (2021) · Nature Materials · doi:10.1038/s41563-020-00814-2 · Cited by 727
Cited by
Motion artefact management for soft bioelectronics
Yin, J., Wang, S., Tat, T., & Chen, J. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00175-4 · Cited by 220
Designing organic mixed conductors for electrochemical transistor applications
Wang, Y., Wustoni, S., Surgailis, J., Zhong, Y., Koklu, A., & Inal, S. (2024) · Nature Reviews Materials · doi:10.1038/s41578-024-00652-7 · Cited by 188
“OMIECs can even be chemically polymerized inside a living tissue, a step towards generating polymeric electrodes embedded in the tissue in the absence of rigid substrate carriers 18 .”
Organic mixed conductors for bioinspired electronics
Gkoupidenis, P., Zhang, Y., Kleemann, H., Ling, H., Santoro, F., Fabiano, S., Salleo, A., & van de Burgt, Y. (2023) · Nature Reviews Materials · doi:10.1038/s41578-023-00622-5 · Cited by 180
“Under these conditions, soft matter can evolve over space and time under the influence of triggering cues such as physical and chemical stimuli, catalysts or thermal energy 32,51,52 .”
Soft hydrogel semiconductors with augmented biointeractive functions
Dai, Y., Wai, S., Li, P., Shan, N., Cao, Z., Li, Y., Wang, Y., Liu, Y., Liu, W., Tang, K., et al. (2024) · Science · doi:10.1126/science.adp9314 · Cited by 175
Metadata
- Authors
- Strakosas, X., Biesmans, H., Abrahamsson, T., Hellman, K., Ejneby, M. S., Donahue, M. J., Ekström, P., Ek, F., Savvakis, M., Hjort, M., Bliman, D., Linares, M., Lindholm, C., Stavrinidou, E., Gerasimov, J. Y., Simon, D. T., Olsson, R., & Berggren, M.
- Venue
- Science
- Published
- 2023-02-24
- Volume
- 379
- Issue
- 6634
- Pages
- 795-802
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W4321749755
- Cited by
- 169
- References
- 37
- FWCI
- 18.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.