Direct observation of motor protein stepping in living cells using MINFLUX
Open accessPublished version of a preprint
Abstract
Dynamic measurements of molecular machines can provide invaluable insights into their mechanism, but these measurements have been challenging in living cells. Here, we developed live-cell tracking of single fluorophores with nanometer spatial and millisecond temporal resolution in two and three dimensions using the recently introduced super-resolution technique MINFLUX. Using this approach, we resolved the precise stepping motion of the motor protein kinesin-1 as it walked on microtubules in living cells. Nanoscopic tracking of motors walking on the microtubules of fixed cells also enabled us to resolve the architecture of the microtubule cytoskeleton with protofilament resolution.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Highly accurate protein structure prediction with AlphaFold
Jumper, J., Evans, R., Pritzel, A., Green, T., Figurnov, M., Ronneberger, O., Tunyasuvunakool, K., Bates, R., Žídek, A., Potapenko, A., et al. (2021) · Nature · doi:10.1038/s41586-021-03819-2 · Cited by 43,764 · see citing works
ColabFold - Making protein folding accessible to all
Mirdita, M., Schütze, K., Moriwaki, Y., Heo, L., Ovchinnikov, S., & Steinegger, M. (2021) · doi:10.1101/2021.08.15.456425 · Cited by 9,391 · see citing works
Yildiz, A., Tomishige, M., Vale, R. D., & Selvin, P. R. (2004) · Science · doi:10.1126/science.1093753 · Cited by 965 · see citing works
Kinesin׳s tail domain is an inhibitory regulator of the motor domain
Coy, D. L., Hancock, W. O., Wagenbach, M., & Howard, J. (1999) · Nature Cell Biology · doi:10.1038/13001 · Cited by 329 · see citing works
Schmidt, R., Weihs, T., Wurm, C. A., Jansen, I., Rehman, J., Sahl, S. J., & Hell, S. W. (2021) · Nature Communications · doi:10.1038/s41467-021-21652-z · Cited by 306 · see citing works
Self-citation‘MINFLUX monitors rapid molecular jumps with superior spatiotemporal resolution’
Eilers, Y., Ta, H., Gwosch, K. C., Balzarotti, F., & Hell, S. W. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1801672115 · Cited by 188 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Mechanism and regulation of kinesin motors.
Yildiz, A. (2025) · Nature reviews. Molecular cell biology · doi:10.1038/s41580-024-00780-6 · Cited by 88 · see citing works
Live-cell imaging powered by computation
Shroff, H., Testa, I., Jug, F., & Manley, S. (2024) · Nature Reviews Molecular Cell Biology · doi:10.1038/s41580-024-00702-6 · Cited by 75 · see citing works
- Authors
- Deguchi, T., Iwanski, M. K., Schentarra, E.-M., Heidebrecht, C., Schmidt, L., Heck, J., Weihs, T., Schnorrenberg, S., Hoess, P., Liu, S., Chevyreva, V., Noh, K.-M., Kapitein, L. C., & Ries, J.
- Affiliations
- European Molecular Biology Laboratory (DE)
- Utrecht University (NL)
- Heidelberg University (DE)
- Abberior Instruments GmbH, Göttingen, Germany.
- University of New Mexico (US)
- IFOM (IT)
- Corresponding author
- Ries, Jonas
- ORCID
- Venue
- Science
- Published
- 2023-03-10
- Volume
- 379
- Issue
- 6636
- Pages
- 1010-1015
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- PMC
- PMC7614483
- OpenAlex
- W4323811077
- Cited by
- 167
- References
- 6
- Citations by year
- 2026: 30 · 2025: 51 · 2024: 51 · 2023: 34 · 2022: 1
- FWCI
- 20.10
- Type
- journal article
- Language
- en
- Open access
- green
- doi.org
- Licence
- cc-by
- Locations
- Science (publishedVersion)
- bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion, cc-by)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Howard Hughes Medical Institute
- European Molecular Biology Laboratory (847543, EMBL001, EIPOD4)
- Horizon 2020 Framework Programme (847543, CoG-724489)
- H2020 European Research Council (819219)
- H2020 Marie Skłodowska-Curie Actions
- HORIZON EUROPE Marie Sklodowska-Curie Actions (847543, H2020, 945405)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Microtubule and mitosis dynamics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
- Keywords
- MINFLUX, kinesin-1, microtubules, super-resolution microscopy, molecular machines, microtubule protofilaments
- MeSH terms
- Cells, Fluorescent Dyes, Humans, Microscopy, Fluorescence, Microtubules, Motion, Kinesins
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review