The DOI matches its Crossref record; 91 of the 91 references it cites were found in a registry or an index.
Dexterous helical magnetic robot for improved endovascular access
Open accessAbstract
Treating vascular diseases in the brain requires access to the affected region inside the body. This is usually accomplished through a minimally invasive technique that involves the use of long, thin devices, such as wires and tubes, that are manually maneuvered by a clinician within the bloodstream. By pushing, pulling, and twisting, these devices are navigated through the tortuous pathways of the blood vessels. The outcome of the procedure heavily relies on the clinician’s skill and the device’s ability to navigate to the affected target region in the bloodstream, which is often inhibited by tortuous blood vessels. Sharp turns require high flexibility, but this flexibility inhibits translation of proximal insertion to distal tip advancement. We present a highly dexterous, magnetically steered continuum robot that overcomes pushability limitations through rotation. A helical protrusion on the device’s surface engages with the vessel wall and translates rotation to forward motion at every point of contact. An articulating magnetic tip allows for active steerability, enabling navigation from the aortic arch to millimeter-sized arteries of the brain. The effectiveness of the magnetic continuum robot has been demonstrated through successful navigation in models of the human vasculature and in blood vessels of a live pig.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“At a larger scale, magnetic field-based technologies are transforming endovascular and neurovascular interventions [153,154,155,156,157,158,159,160].”
In the citing paper
“Soft robots, steerable catheters, and magnetic microbots allow non-traumatic vascular navigation, targeted drug or clot therapies, and on-demand embolization [153,155,156,157,158,159,160] with MRI-guided magnetic navigation enhancing visualization and safety [17,155,156].”
In the citing paper
“Early pilots confirm feasibility, though issues of device visibility, retrieval, chronic biocompatibility, and workflow integration require further investigation [153,155,156,157,158,159,160].”
Citations
Cites
ROS: an open-source Robot Operating System
Quigley, M. (2009) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · Cited by 8,729
Microrobots for Minimally Invasive Medicine
Nelson, B. J., Kaliakatsos, I. K., & Abbott, J. J. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-010510-103409 · Cited by 1,968
Self-citationGlobal Epidemiology of Stroke and Access to Acute Ischemic Stroke Interventions
Saini, V., Guada, L., & Yavagal, D. R. (2021) · Neurology · doi:10.1212/wnl.0000000000012781 · Cited by 1,356
Ferromagnetic soft continuum robots
Kim, Y., Parada, G. A., Liu, S., & Zhao, X. (2019) · Science Robotics · doi:10.1126/scirobotics.aax7329 · Cited by 1,312
Medical robotics—Regulatory, ethical, and legal considerations for increasing levels of autonomy
Yang, G.-Z., Cambias, J., Cleary, K., Daimler, E., Drake, J., Dupont, P. E., Hata, N., Kazanzides, P., Martel, S., Patel, R. V., et al. (2017) · Science Robotics · doi:10.1126/scirobotics.aam8638 · Cited by 741
A decade retrospective of medical robotics research from 2010 to 2020
Dupont, P. E., Nelson, B. J., Goldfarb, M., Hannaford, B., Menciassi, A., O’Malley, M. K., Simaan, N., Valdastri, P., & Yang, G.-Z. (2021) · Science Robotics · doi:10.1126/scirobotics.abi8017 · Cited by 516
Self-citationTelerobotic neurovascular interventions with magnetic manipulation
Kim, Y., Genevriere, E., Harker, P., Choe, J., Balicki, M., Regenhardt, R. W., Vranic, J. E., Dmytriw, A. A., Patel, A. B., & Zhao, X. (2022) · Science Robotics · doi:10.1126/scirobotics.abg9907 · Cited by 422
van der Worp, H. B., & van Gijn, J. (2007) · New England Journal of Medicine · doi:10.1056/nejmcp072057 · Cited by 399
Treatment of Acute Ischemic Stroke
Brott, T., & Bogousslavsky, J. (2000) · New England Journal of Medicine · doi:10.1056/nejm200009073431007 · Cited by 398
Jeon, S., Hoshiar, A. K., Kim, K., Lee, S., Kim, E., Lee, S., Kim, J.-Y., Nelson, B. J., Cha, H.-J., Yi, B.-J., et al. (2019) · Soft Robotics · doi:10.1089/soro.2018.0019 · Cited by 301
Self-citationAttanasio, A., Scaglioni, B., De Momi, E., Fiorini, P., & Valdastri, P. (2021) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-062420-090543 · Cited by 263
Enabling the future of colonoscopy with intelligent and autonomous magnetic manipulation
Martin, J. W., Scaglioni, B., Norton, J. C., Subramanian, V., Arezzo, A., Obstein, K. L., & Valdastri, P. (2020) · Nature Machine Intelligence · doi:10.1038/s42256-020-00231-9 · Cited by 208
Hwang, J., Kim, J.-Y., & Choi, H. (2020) · Intelligent Service Robotics · doi:10.1007/s11370-020-00311-0 · Cited by 181
Soft robotic steerable microcatheter for the endovascular treatment of cerebral disorders
Gopesh, T., Wen, J. H., Santiago-Dieppa, D. R., Yan, B., Pannell, J. S., Khalessi, A. A., Norbash, A., & Friend, J. R. (2021) · Science Robotics · doi:10.1126/scirobotics.abf0601 · Cited by 161
Robot-assisted Fenestrated Endovascular Aneurysm Repair (FEVAR) Using the Magellan System
Riga, C. V., Bicknell, C. D., Rolls, A., Cheshire, N. J. W., & Hamady, M. (2013) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2012.10.006 · Cited by 152
First-in-human, robotic-assisted neuroendovascular intervention
Pereira, V. M., Cancelliere, N. M., Nicholson, P. J., Radovanovic, I., Drake, K. E., Sungur, J., Krings, T., & Turk, A. S. (2020) · Journal of NeuroInterventional Surgery · doi:10.1136/neurintsurg-2019-015671.rep · Cited by 151
Patient-Specific Magnetic Catheters for Atraumatic Autonomous Endoscopy
Pittiglio, G., Lloyd, P., da Veiga, T., Onaizah, O., Pompili, C., Chandler, J. H., & Valdastri, P. (2022) · Soft Robotics · doi:10.1089/soro.2021.0090 · Cited by 144
Adaptive wireless millirobotic locomotion into distal vasculature
Wang, T., Ugurlu, H., Yan, Y., Li, M., Li, M., Wild, A., Yıldız, E., Schneider, M., Sheehan, D., Hu, W., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-32059-9 · Cited by 143
Contact and friction between catheter and blood vessel
TAKASHIMA, K., Shimomura, R., Kitou, T., Terada, H., Yoshinaka, K., & IKEUCHI, K. (2006) · Tribology International · doi:10.1016/j.triboint.2005.10.010 · Cited by 134
Thermoset Shape Memory Polymer Variable Stiffness 4D Robotic Catheters
Mattmann, M., Marco, C. D., Vangosa, F. B., Tagliabue, S., Colusso, A., Chen, X., Lussi, J., Chautems, C., Pané, S., & Nelson, B. J. (2021) · Advanced Science · doi:10.1002/advs.202103277 · Cited by 122
Self-citationRai, A., Hogg, J. P., Cline, B. C., & Hobbs, G. R. (2012) · Journal of NeuroInterventional Surgery · doi:10.1136/neurintsurg-2012-010314 · Cited by 117
Overview of Mechanical Thrombectomy Techniques
Munich, S. A., Vakharia, K. V., & Levy, E. I. (2019) · Neurosurgery · doi:10.1093/neuros/nyz071 · Cited by 117
Neurovascular Modeling: Small-Batch Manufacturing of Silicone Vascular Replicas
Chueh, J.-Y., Wakhloo, A. K., & Gounis, M. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1543 · Cited by 106
Kaesmacher, J., Gralla, J., Mosimann, P. J., Zibold, F., Heldner, M. R., Piechowiak, E. I. I., Dobrocky, T., Arnold, M., Fischer, U., & Mordasini, P. (2018) · American Journal of Neuroradiology · doi:10.3174/ajnr.a5759 · Cited by 102
Magnetic Control of a Steerable Guidewire Under Ultrasound Guidance Using Mobile Electromagnets
Yang, Z., Yang, L., Zhang, M., Wang, Q., Simon, C. H., & Zhang, L. (2021) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2021.3057295 · Cited by 102
Steerable Catheters in Cardiology: Classifying Steerability and Assessing Future Challenges
Ali, A., Plettenburg, D. H., & Breedveld, P. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2525785 · Cited by 101
Vascular Guide Wire Navigation with a Magnetic Guidance System: Experimental Results in a Phantom
Schiemann, M., Killmann, R., Kleen, M. S., Abolmaali, N., Finney, J., & Vogl, T. J. (2004) · Radiology · doi:10.1148/radiol.2322030533 · Cited by 96
Lee, S., Lee, S.-M., Kim, S., Yoon, C.-H., Park, H., Kim, J., & Choi, H. (2018) · Scientific Reports · doi:10.1038/s41598-018-22110-5 · Cited by 95
Bakenecker, A. C., von Gladiss, A., Schwenke, H., Behrends, A., Friedrich, T., Lüdtke‐Buzug, K., Neumann, A., Barkhausen, J., Wegner, F., & Buzug, T. M. (2021) · Scientific Reports · doi:10.1038/s41598-021-93323-4 · Cited by 90
Development of a Tactile Sensing Robot-Assisted System for Vascular Interventional Surgery
Jin, X., Guo, S., Guo, J. F., Shi, P., Tamiya, T., & Hirata, H. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3066424 · Cited by 89
Mechanical Rubbing of Blood Clots Using Helical Robots Under Ultrasound Guidance
Khalil, I. S. M., Mahdy, D. S. A., Sharkawy, A. E., Moustafa, R. R., Tabak, A. F., Mitwally, M. E., Hesham, S., Hamdi, N., Klingner, A., Mohamed, A., et al. (2018) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2018.2792156 · Cited by 88
Rubbing Against Blood Clots Using Helical Robots: Modeling and In Vitro Experimental Validation
Khalil, I. S. M., Tabak, A. F., Sadek, K., Mahdy, D. S. A., Hamdi, N., & Sitti, M. (2017) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2017.2654546 · Cited by 85
Patel, T. M., Shah, S. C., Soni, Y. Y., Radadiya, R., Patel, G. A., Tiwari, P., & Pancholy, S. B. (2020) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.119.008888 · Cited by 83
Montalverne, F. J., Lima, F. O., Rocha, F., Bandeira, D., de Lucena, A. F., Silva, H. C., Lee, J. S., & Nogueira, R. G. (2020) · Journal of Stroke · doi:10.5853/jos.2020.00227 · Cited by 82
Total motorized spiral enteroscopy: first prospective clinical feasibility trial
ten Beyna, T., Arvanitakis, M., Schneider, M., Gerges, C., Höllerich, J., Deviere, J. M. E., & Neuhaus, H. (2020) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2020.10.028 · Cited by 80
Catheter Ablation Utilizing Remote Magnetic Navigation: A Review of Applications and Outcomes
Bradfield, J. S., Tung, R. H., Mandapati, R., Boyle, N. G., & Shivkumar, K. (2012) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2012.03382.x · Cited by 79
Model-Based Calibration for Magnetic Manipulation
Petruska, A. J., Edelmann, J., & Nelson, B. J. (2017) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2017.2653080 · Cited by 78
Self-citationLeclerc, J., Zhao, H., Bao, D., & Becker, A. T. (2020) · IEEE Transactions on Robotics · doi:10.1109/tro.2020.2988636 · Cited by 78
A Review of Robotic Interventional Neuroradiology
Beaman, C. B., Kaneko, N., Meyers, P. M., & Tateshima, S. (2021) · American Journal of Neuroradiology · doi:10.3174/ajnr.a6976 · Cited by 73
Grundeken, M. J., Li, X., Kurpershoek, C. E., Kramer, M. C. A., Vink, A., Piek, J. J., Tijssen, J. G. P., Koch, K. T., Wykrzykowska, J. J., de Winter, R. J., et al. (2015) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.114.001816 · Cited by 69
Chun, K. R. J., Wißner, E., Koektuerk, B., Konstantinidou, M., Schmidt, B., Zerm, T., Metzner, A., Tilz, R. R., Boczor, S., Fuernkranz, A., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.110.942672 · Cited by 66
Design optimization of a shape memory alloy–actuated robotic catheter
Crews, J. H., & Buckner, G. D. (2012) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x12436738 · Cited by 66
Zhang, S., Yin, M. D., Lai, Z., Huang, C., Wang, C., Shang, W., Wu, X., Zhang, Y., & Xu, T. (2022) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2022.3146909 · Cited by 62
The functional vascular anatomy of the swine for research
Edwards, J., Abdou, H., Patel, N., Madurska, M. J., Poe, K., Bonin, J. E., Richmond, M. J., Rasmussen, T. E., & Morrison, J. J. (2021) · Vascular · doi:10.1177/1708538121996500 · Cited by 61
3D path planning for flexible needle steering in neurosurgery
Hong, A., Boehler, Q., Moser, R., Zemmar, A., Stieglitz, L. H., & Nelson, B. J. (2019) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.1998 · Cited by 58
Self-citationBritz, G. W., Tomas, J., & Lumsden, A. B. (2019) · Neurosurgery · doi:10.1093/neuros/nyz064 · Cited by 58
Magnetic versus manual guidewire manipulation in neuroradiology: in vitro results
Krings, T., Finney, J., Niggemann, P., Reinacher, P. C., Lück, N., Drexler, A. Y., Lovell, J. F., Meyer, A., Sehra, R., SCHAUERTE, P. N., et al. (2006) · Neuroradiology · doi:10.1007/s00234-006-0082-3 · Cited by 54
Karstensen, L., Ritter, J., Hatzl, J., Pätz, T., Langejürgen, J., Uhl, C., & Mathis-Ullrich, F. (2022) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-022-02646-8 · Cited by 53
Three-Degree-of-Freedom MR-Compatible Multisegment Cardiac Catheter Steering Mechanism
Ataollahi, A., Karim, R., Fallah, A. S., Rhode, K., Razavi, R., Seneviratne, L. D., Schaeffter, T., & Althoefer, K. A. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2276739 · Cited by 50
Transradial versus transfemoral approach for cerebral angiography: A prospective comparison
Wang, Z., Xia, J., Wang, W., Xu, G., Gu, J., Wang, Y., & Li, T. (2019) · Journal of interventional medicine · doi:10.1016/j.jimed.2019.05.008 · Cited by 44
X-ray to MR: the progress of flexible instruments for endovascular navigation
Abdelaziz, M. E. M. K., Tian, L., Hamady, M., Yang, G., & Temelkuran, B. (2021) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ac12d6 · Cited by 41
A Simulation Framework for Magnetic Continuum Robots
Dreyfus, R., Boehler, Q., & Nelson, B. J. (2022) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2022.3187249 · Cited by 41
Self-citationOn the Workspace of Electromagnetic Navigation Systems
Boehler, Q., Gervasoni, S., Charreyron, S., Chautems, C., & Nelson, B. J. (2022) · IEEE Transactions on Robotics · doi:10.1109/tro.2022.3197107 · Cited by 41
Self-citationSheng, J., Wang, X., Dickfeld, T.-M. L., & Desai, J. P. (2018) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2018.2861011 · Cited by 40
The post-buckling behavior of a beam constrained by springy walls
Katz, S. M., & Givli, S. (2015) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2015.02.004 · Cited by 39
Hosney, A., Klingner, A., Misra, S., & Khalil, I. S. M. (2015) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2015.7353639 · Cited by 38
How to select a guidewire: technical features and key characteristics
Tóth, G. G., Yamane, M., & Heyndrickx, G. R. (2014) · Heart · doi:10.1136/heartjnl-2013-304243 · Cited by 37
A Sensor-less Catheter Contact Force Estimation Approach in Endovascular Intervention Procedures
Razban, M., Dargahi, J., & Boulet, B. (2018) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2018.8593387 · Cited by 35
Separable and Recombinable Magnetic Robot for Robotic Endovascular Intervention
Sa, J., Park, J., Jung, E., Kim, N., Lee, D., Bae, S., Lee, Y., & Jang, G. (2023) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2023.3243801 · Cited by 33
Candio, P., Violato, M., Leal, J., & Luengo-Fernández, R. (2021) · Stroke · doi:10.1161/strokeaha.120.031027 · Cited by 31
Robotics in therapeutic endoscopy (with video)
Cui, Y., Thompson, C. C., Chiu, P. W. Y., & Gross, S. A. (2022) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2022.05.019 · Cited by 31
Design and Experimental Validation of an Active Catheter for Endovascular Navigation
Couture, T., & Szewczyk, J. (2017) · Journal of Medical Devices · doi:10.1115/1.4038334 · Cited by 29
Swimming characteristics of helical microrobots in fibrous environments
Mathis-Ullrich, F., Qiu, F., Pokki, J., Huang, T., Pané, S., & Nelson, B. J. (2016) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2016.7523671 · Cited by 28
Self-citationUse of Stents to Treat Intracranial Cerebrovascular Disease
Meyers, P. M., Schumacher, H. C., Tanji, K., Higashida, R. T., & Caplan, L. R. (2006) · Annual Review of Medicine · doi:10.1146/annurev.med.58.121205.100631 · Cited by 28
Dual-body magnetic helical robot for drilling and cargo delivery in human blood vessels
Lee, W., Jeon, S., Nam, J., & Jang, G. (2015) · Journal of Applied Physics · doi:10.1063/1.4917067 · Cited by 27
Human placenta as an ex vivo vascular model for neurointerventional research
Kwok, J. C. K., Huang, W., Leung, W., Chan, S., Chan, K., Leung, K., Chu, A. C. H., & Lam, A. K. N. (2013) · Journal of NeuroInterventional Surgery · doi:10.1136/neurintsurg-2013-010813 · Cited by 25
Language of CTO interventions – Focus on hardware
Mishra, S. (2016) · Indian Heart Journal · doi:10.1016/j.ihj.2016.06.015 · Cited by 25
Neurointerventional Robotics: Challenges and Opportunities
Goyal, M., Sutherland, G. R., Lama, S., Cimflová, P., Kashani, N., Mayank, A., Psychogios, M., Spelle, L., Costalat, V., Sakai, N., et al. (2020) · Clinical Neuroradiology · doi:10.1007/s00062-020-00913-2 · Cited by 25
Automated Planning for Robotic Guidewire Navigation in the Coronary Arteries
Schegg, P., Dequidt, J., Coevoet, E., Leurent, E., Sabatier, R., Preux, P., & Christian Duriez, A. (2022) · IEEE International Conference on Soft Robotics (RoboSoft) · doi:10.1109/robosoft54090.2022.9762096 · Cited by 24
Sidiq, M., Scheidecker, E., Potreck, A., Neuberger, U., Weyland, C. S., Mundiyanapurath, S., Bendszus, M., Möhlenbruch, M. A., & Şeker, F. (2022) · Clinical Neuroradiology · doi:10.1007/s00062-022-01181-y · Cited by 22
Magnetically Guided Laser Surgery for the Treatment of Twin‐to‐Twin Transfusion Syndrome
Lussi, J., Gervasoni, S., Mattille, M., Dreyfus, R., Boehler, Q., Reinehr, M. D., Ochsenbein‐Kölble, N., Nelson, B. J., & Moehrlen, U. (2022) · Advanced Intelligent Systems · doi:10.1002/aisy.202200182 · Cited by 22
Self-citationYun, C.-H., Yeo, L. Y., Friend, J. R., & Yan, B. (2012) · Applied Physics Letters · doi:10.1063/1.3702579 · Cited by 21
Steerable Guidewire for Magnetic Resonance Guided Endovascular Interventions
Clogenson, H. C. M., Dankelman, J., & van den Dobbelsteen, J. J. (2014) · Journal of Medical Devices · doi:10.1115/1.4026560 · Cited by 21
Vertebral artery origin stenting with buddy wire technique in tortuous subclavian artery
Kızılkılıç, O. (2006) · European Journal of Radiology · doi:10.1016/j.ejrad.2006.08.023 · Cited by 21
Ultrasound-guided minimally invasive grinding for clearing blood clots: promises and challenges
Mahdy, D. S. A., Reda, R., Hamdi, N., & Khalil, I. S. M. (2018) · IEEE Instrumentation & Measurement Magazine · doi:10.1109/mim.2018.8327972 · Cited by 19
Karstensen, L., Ritter, J., Hatzl, J., Ernst, F., Langejürgen, J., Uhl, C., & Mathis-Ullrich, F. (2023) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-023-02938-7 · Cited by 19
Neuroendovascular magnetic navigation: clinical experience in ten patients
Dabus, G. C., Gerstle, R. J., Cross, D. T., Derdeyn, C. P., & Moran, C. J. (2007) · Neuroradiology · doi:10.1007/s00234-006-0202-0 · Cited by 17
Bydlon, T. M., Torjesen, A. A., Fokkenrood, S., Tullio, A. D., & Flexman, M. L. (2023) · EJVES Vascular Forum · doi:10.1016/j.ejvsvf.2023.05.006 · Cited by 16
Screw-Tip Soft Magnetically Steerable Needles
Sperry, A. J., Schwehr, T. J., Pinegar, E. K., Richards, O. B., Rolston, J. D., Alexander, M. D., Coats, B., Abbott, J. J., & Kuntz, A. (2023) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2023.3265721 · Cited by 12
Wiest, J. H., & Buckner, G. D. (2014) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.10.019 · Cited by 10
Yu, C., & Kim, S. H. (2016) · Journal of Magnetics · doi:10.4283/jmag.2016.21.4.616 · Cited by 9
Deflection modeling of permanent magnet spherical chains in the presence of external magnetic fields
O’Donoghue, K., & Cantillon‐Murphy, P. (2013) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2013.05.006 · Cited by 6
Gradient-based Design Optimization of Shape Memory Alloy Active Catheters
Langelaar, M., & van Keulen, F. (2007) · AIAA/ASME/ASCE/AHS/ASC Structures, Structural Dynamics, and Materials Conference (SDM) · doi:10.2514/6.2007-1744 · Cited by 6
Burel, J., Cornacchini, J., Garnier, M., Patrier, S., Guigné, A., Gérardin, E., Papagiannaki, C., Sourour, N. A., Shotar, E., Premat, K., et al. (2022) · Frontiers in Neurology · doi:10.3389/fneur.2022.925763 · Cited by 5
Multi-Scale Robotics Lab, E. Z., Dreyfus, R., Boehler, Q., Chautems, C., & Nelson, B. J. (2022) · Hamlyn Symposium on Medical Robotics (HSMR) · doi:10.31256/hsmr2022.39 · Cited by 4
Self-citationClosed-form Kinematic Model and Workspace Characterization for Magnetic Ball Chain Robots
Pittiglio, G., Mencattelli, M., & Dupont, P. E. (2023) · International Symposium on Medical Robotics · doi:10.1109/ismr57123.2023.10130219 · Cited by 3
Usefulness of the Turnpike Gold Catheter in Balloon Uncrossable Coronary Lesions
Egred, M. (2020) · Clinical Cardiology and Cardiovascular Interventions · doi:10.31579/2641-0419/064 · Cited by 2
A CI Study in Cerebral Angiography for Product Development Strategy and Clinical Training
Privitera, M. B., & Ringer, A. J. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-801852-1.00008-3 · Cited by 1
Pressure pulse driven method for precise bending control of hydraulic active catheter
Ikuta, K., MATSUDA, Y., Yajima, D., & Ota, Y. (2010) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2010.5627740 · Cited by 1
Caenazzo, A., & Althoefer, K. A. (2018) · Lecture notes in computer science · doi:10.1007/978-3-319-96728-8_24 · Cited by 1
Novel Technique to Cross Infrapopliteal Artery Chronic Total Occlusions
Purushottam, B., & Krishnan, P. (2020) · Journal of Vascular and Endovascular Therapy · doi:10.21767/2573-4482.20.05.22 · Cited by 1
Research works printed but not linked: 3
- Y. Haga Y. Muyari T. Mineta T. Matsunaga H. Akahori M. Esashi Small diameter hydraulic active bending catheter using laser processed super elastic alloy and silicone rubber tube in 2005 3rd IEEE/EMBS Special Topic Conference on Microtechnology in Medicine and Biology (IEEE 2005) Oahu HI USA 12 to 15 May 2005.
- K. Ishiyama K. I. Arai M. Sendoh A. Yamazaki Spiral-type micro-machine for medical applications in MHS2000. Proceedings of 2000 International Symposium on Micromechatronics and Human Science (Cat. No.00TH8530) (IEEE 2000) Nagoya Japan 22 to 25 October 2000.
- P. M. Scheikl B. Gyenes R. Younis C. Haas G. Neumann M. Wagner F. Mathis-Ullrich LapGym – An open source framework for reinforcement learning in robot-assisted laparoscopic surgery. arXiv: 2302.09606 (2023). · arXiv
Cited by
Soft Materials and Devices Enabling Sensorimotor Functions in Soft Robots
Su, J., He, K., Li, Y., Tu, J., & Chen, X. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00906 · Cited by 124
Gervasoni, S., Pedrini, N., Rifai, T., Fischer, C., Landers, F. C., Mattmann, M., Dreyfus, R., Viviani, S., Veciana, A., Masina, E., et al. (2024) · Advanced Materials · doi:10.1002/adma.202310701 · Cited by 79
Self-citationHuo, Y., Yang, L., Xu, T., & Sun, D. B. (2024) · Advanced Intelligent Systems · doi:10.1002/aisy.202400403 · Cited by 64
Magnetic Continuum Robot for Intelligent Manipulation in Medical Applications
Ma, Y., An, X., Yang, Q., Cai, M., Tang, Z., Chang, J., Iacovacci, V., Xu, T., Zhang, L., & Wang, Q. (2025) · SmartBot · doi:10.1002/smb2.12011 · Cited by 56
Multi-Section Magnetic Soft Robot with Multirobot Navigation System for Vasculature Intervention
Li, Z., & Xu, Q. (2024) · Cyborg and Bionic Systems · doi:10.34133/cbsystems.0188 · Cited by 55
Metadata
- Authors
- Dreyfus, R., Boehler, Q., Lyttle, S., Gruber, P., Lussi, J., Chautems, C., Gervasoni, S., Berberat, J., Seibold, D., Ochsenbein-Kölble, N., Reinehr, M., Weisskopf, M., Remonda, L., & Nelson, B. J.
- Affiliations
- ETH Zurich (CH)
- Kantonsspital Aarau (CH)
- Department of Obstetrics, University Hospital Zurich, Zurich, Switzerland.
- University of Zurich (CH)
- Corresponding author
- Nelson, B. J.
- ORCID
- Venue
- Science Robotics
- Published
- 2024-02-14
- Volume
- 9
- Issue
- 87
- Pages
- eadh0298-eadh0298
- ISSN
- 2470-9476 (ISSN-L)
- OpenAlex
- W4391807372
- Cited by
- 185
- References
- 91
- Citations by year
- 2026: 72 · 2025: 86 · 2024: 27
- FWCI
- 20.37
- Type
- journal article
- Language
- en
- Open access
- Licence
- other-oa
- Locations
- Science Robotics (publishedVersion)
- PubMed (publishedVersion)
- Repository for Publications and Research Data (ETH Zurich) (submittedVersion, other-oa)
- Zurich Open Repository and Archive (University of Zurich) (submittedVersion)
- ETH Zürich Research Collection
- Funders
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (185039)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Physical Sciences › Physics and Astronomy › Condensed Matter Physics › Micro and Nano Robotics
- Physical Sciences › Engineering › Mechanical Engineering › Advanced Materials and Mechanics
- Keywords
- endovascular navigation, cerebrovascular disease, minimally invasive neurosurgery, magnetic tip, vascular access
- MeSH terms
- Animals, Humans, Motion, Robotics, Swine, Magnetic Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.