The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
First-in-Human Testing of a Wirelessly Controlled Drug Delivery Microchip
Abstract
Implanted in humans, a wirelessly controlled, microchip-based drug delivery device demonstrates pharmacokinetic profiles of an anti-osteoporosis drug that are similar to subcutaneous injections.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neer, R. M., Arnaud, C. D., Zanchetta, J. R., Prince, R., Gaich, G. A., Reginster, J.-Y., Hodsman, A. B., Eriksen, E. F., Ish-Shalom, S., Genant, H. K., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200105103441904 · Cited by 4,602
Self-citationIncidence and Economic Burden of Osteoporosis-Related Fractures in the United States, 2005–2025
Burge, R., Dawson-Hughes, B., Solomon, D. H., Wong, J. B., King, A., & Tosteson, A. (2007) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.061113 · Cited by 4,026
A Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O'Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032441 · Cited by 2,749
Biological Responses to Materials
Anderson, J. M. (2001) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.31.1.81 · Cited by 1,465
Self-citationA controlled-release microchip
Santini, J. T., Cima, M. J., & Langer, R. (1999) · Nature · doi:10.1038/16898 · Cited by 868
Self-citationKratz (2004) · doi:10.1056/nejmcpc049016 · Cited by 593
Multi-pulse drug delivery from a resorbable polymeric microchip device
Grayson, A. C. R., Choi, I. S., Tyler, B. M., Wang, P. P., Brem, H., Cima, M. J., & Langer, R. (2003) · Nature Materials · doi:10.1038/nmat998 · Cited by 444
Self-citationHock, J. M., & Gera, I. (1992) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650070110 · Cited by 367
Dobnig, H. (1997) · Endocrinology · doi:10.1210/en.138.11.4607 · Cited by 322
Chronic, programmed polypeptide delivery from an implanted, multireservoir microchip device
Prescott, J. H., Lipka, S., Baldwin, S., Sheppard, N. F., Maloney, J. M., Coppeta, J., Yomtov, B., Staples, M. A., & Santini, J. T. (2006) · Nature Biotechnology · doi:10.1038/nbt1199 · Cited by 219
Self-citation
Research works printed but not linked: 5
- 10.1007/s11095-007-9243-2 · doi:10.1007/s11095-007-9243-2
- 10.1007/s11095-008-9544-0 · doi:10.1007/s11095-008-9544-0
- Perry L., Karp F., Hauch K., Ratner B. D., Explanted pacemakers: Observations of the long-term foreign body response. J. Undergrad. Res. Bioeng. 7, 13–21 (2007).
- WHO Scientific Group on the Assessment of Osteoporosis at Primary Health Care Level Summary Meeting Report Brussels Belgium 5-7 May 2004 (WHO Press Geneva Switzerland 2007).
- 10.1210/endo.138.11.5505 · doi:10.1210/endo.138.11.5505 · Paper page
Cited by
Therapeutic Peptides: Current Applications and Future Directions
Wang, L., Wang, N., Zhang, W., Cheng, X., Yan, Z., Shao, G., Wang, X., Wang, R., & Fu, C. (2022) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-022-00904-4 · Cited by 2,131
Overcoming the challenges in administering biopharmaceuticals: Formulation and delivery strategies
Mitragotri, S., Burke, P. A., & Langer, R. (2014) · Nature Reviews Drug Discovery · doi:10.1038/nrd4363 · Cited by 1,702
Self-citationMultifunctional wearable devices for diagnosis and therapy of movement disorders
Son, D., Lee, J., Qiao, S., Ghaffari, R., Kim, J., Lee, J. E., Song, C., Kim, S. J., Lee, D. J., Jun, S. W., et al. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.38 · Cited by 1,462
Lu, Y., Aimetti, A. A., Langer, R., & Gu, Z. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.75 · Cited by 1,421
Self-citationRecent Advances in Flexible and Stretchable Bio‐Electronic Devices Integrated with Nanomaterials
Choi, S., Lee, H., Ghaffari, R., Hyeon, T., & Kim, D. (2016) · Advanced Materials · doi:10.1002/adma.201504150 · Cited by 1,104
Metadata
- Authors
- Farra, R., Sheppard, N. F., McCabe, L., Neer, R. M., Anderson, J. M., Santini, J. T., Cima, M. J., & Langer, R.
- Venue
- Science Translational Medicine
- Published
- 2012-02-22
- Volume
- 4
- Issue
- 122
- Pages
- 122ra21-122ra21
- ISSN
- 1946-6234 (ISSN-L)
- 1946-6242
- OpenAlex
- W2150250592
- Cited by
- 437
- References
- 16
- FWCI
- 21.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: First-in-Human Testing of a Wirelessly Controlled Drug Delivery Microchip. https://app.cochat.ai/papers/10.1126/scitranslmed.3003276
- The paper
- Farra, R., Sheppard, N. F., McCabe, L., Neer, R. M., Anderson, J. M., Santini, J. T., Cima, M. J., & Langer, R. (2012). First-in-Human Testing of a Wirelessly Controlled Drug Delivery Microchip. Science Translational Medicine. https://doi.org/10.1126/scitranslmed.3003276
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.