The DOI matches its Crossref record; 35 of the 36 references it cites were found in a registry or an index.
Clinical trial of blood-brain barrier disruption by pulsed ultrasound
Abstract
An implantable ultrasound device safely disrupts the blood-brain barrier in glioblastoma patients.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Disruption of the lipid organization of membranes by ultrasound increases membrane permeability and allows greater penetration of the therapeutic molecules [257].”
From Alzheimer's Disease: Treatment Strategies and Their Limitations. (2022) · cites this paper as [257]
Citations
Cites
Wen, P. Y., Macdonald, D. R., Reardon, D. A., Cloughesy, T. F., Sorensen, A. G., Galanis, E., DeGroot, J. F., Wick, W., Gilbert, M. R., Lassman, A. B., et al. (2010) · Journal of Clinical Oncology · doi:10.1200/jco.2009.26.3541 · Cited by 3,890
Carboplatin dosage: prospective evaluation of a simple formula based on renal function.
Calvert, H., Newell, D. R., Gumbrell, L. A., O’Reilly, S., Burnell, M., Boxall, F. E., Siddik, Z. H., Judson, I. R., Gore, M. E., & Wiltshaw, E. (1989) · Journal of Clinical Oncology · doi:10.1200/jco.1989.7.11.1748 · Cited by 1,862
Noninvasive MR Imaging–guided Focal Opening of the Blood-Brain Barrier in Rabbits
Hynynen, K., McDannold, N. J., Vykhodtseva, N. I., & Jolesz, F. A. (2001) · Radiology · doi:10.1148/radiol.2202001804 · Cited by 1,463
Direct brain infusion of glial cell line–derived neurotrophic factor in Parkinson disease
Gill, S. S., Patel, N. K., Hotton, G. R., O'Sullivan, K., McCarter, R., Bunnage, M., Brooks, D. J., Svendsen, C. N., & Heywood, P. (2003) · Nature Medicine · doi:10.1038/nm850 · Cited by 1,290
Accelerated Titration Designs for Phase I Clinical Trials in Oncology
Simon, R. M., Rubinstein, L., Arbuck, S. G., Christian, M. C., Freidlin, B., & Collins, J. M. (1997) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/89.15.1138 · Cited by 641
McDannold, N. J., Arvanitis, C., Vykhodtseva, N. I., & Livingstone, M. S. (2012) · Cancer Research · doi:10.1158/0008-5472.can-12-0128 · Cited by 600
Scanning ultrasound removes amyloid-β and restores memory in an Alzheimer’s disease mouse model
Leinenga, G., & Götz, J. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa2512 · Cited by 498
Liu, H.-L., Hua, M., Chen, P.-Y., Chu, P.-C., Pan, C.-H., Yang, H.-W., Huang, C.-Y., Wang, J.-J., Yen, T., & Wei, K.-C. (2010) · Radiology · doi:10.1148/radiol.10090699 · Cited by 387
Jordão, J. F., Thévenot, E., Markham-Coultes, K., Scarcelli, T., Weng, Y.-Q., Xhima, K., O'Reilly, M., Huang, Y., McLaurin, J., Hynynen, K., et al. (2013) · Experimental Neurology · doi:10.1016/j.expneurol.2013.05.008 · Cited by 326
Treat, L. H., McDannold, N. J., Zhang, Y., Vykhodtseva, N. I., & Hynynen, K. (2012) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.04.015 · Cited by 296
Cited by
Sorted by citations
The blood–brain barrier and blood–tumour barrier in brain tumours and metastases
Arvanitis, C., Ferraro, G. B., & Jain, R. K. (2019) · Nature reviews. Cancer · doi:10.1038/s41568-019-0205-x · Cited by 1,919
van der Meel, R., Sulheim, E., Shi, Y., Kiessling, F. M., Mulder, W. J. M., & Lammers, T. (2019) · Nature Nanotechnology · doi:10.1038/s41565-019-0567-y · Cited by 1,279
Strategies for delivering therapeutics across the blood–brain barrier
Terstappen, G. C., Meyer, A. H., Bell, R. D., & Zhang, W. (2021) · Nature Reviews Drug Discovery · doi:10.1038/s41573-021-00139-y · Cited by 1,138
Rethinking cancer nanotheranostics
Chen, H., Zhang, W., Zhu, G., Xie, J., & Chen, X. S. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.24 · Cited by 1,113
Challenges to curing primary brain tumours
Aldape, K., Brindle, K. M., Chesler, L., Chopra, R., Gajjar, A., Gilbert, M. R., Gottardo, N., Gutmann, D. H., Hargrave, D., Holland, E. C., et al. (2019) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-019-0177-5 · Cited by 959
Metadata
- Authors
- Carpentier, A., Canney, M., Vignot, A., Reina, V., Beccaria, K., Horodyckid, C., Karachi, C., Leclercq, D., Lafon, C., Chapelon, J.-Y., Capelle, L., Cornu, P., Sanson, M., Hoang-Xuan, K., Delattre, J.-Y., & Idbaih, A.
- Affiliations
- Sorbonne Université (FR)
- Institut du Cerveau (FR)
- Assistance Publique–Hôpitaux de Paris (AP-HP), Hôpitaux Universitaires La Pitié-Salpêtrière, Service de Neurochirurgie, F-75013 Paris, France.
- Assistance Publique – Hôpitaux de Paris (FR)
- Inserm (FR)
- Centre National de la Recherche Scientifique (FR)
- Sorbonne Universités, UPMC Univ Paris 06, UMR S 1127, F-75013 Paris, France.
- Corresponding author
- Carpentier, Alexandre
- ORCID
- Venue
- Science Translational Medicine
- Published
- 2016-06-15
- Volume
- 8
- Issue
- 343
- Pages
- 343re2-343re2
- ISSN
- 1946-6234 (ISSN-L)
- 1946-6242
- OpenAlex
- W2433010802
- Cited by
- 757
- References
- 36
- Citations by year
- 2026: 55 · 2025: 74 · 2024: 75 · 2023: 73 · 2022: 92 · 2021: 104 · 2020: 101 · 2019: 73 · 2018: 65 · 2017: 34 · 2016: 10
- FWCI
- 29.25
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Science Translational Medicine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- CarThera (#12109)
- Investissements d'avenir (ANR-10-IAIHU-06)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Ultrasound and Hyperthermia Applications
- Life Sciences › Neuroscience › Neurology › Barrier Structure and Function Studies
- Health Sciences › Medicine › Oncology › Glioma Diagnosis and Treatment
- Keywords
- blood-brain barrier disruption, pulsed ultrasound, recurrent glioblastoma, carboplatin, microbubbles, contrast-enhanced MRI
- MeSH terms
- Ultrasonic Waves, Blood-Brain Barrier, Brain, Female, Glioblastoma, Humans, Magnetic Resonance Imaging, Male, Carboplatin, Microbubbles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review