The DOI matches its Crossref record.
Bioluminescent sensors for detection of bioavailable Hg(II) in the environment
Open accessAbstract
Biosensors for the detection of pollutants in the environment can complement analytical methods by distinguishing bioavailable from inert, unavailable forms of contaminants. By using fusions of the well-understood Tn21 mercury resistance operon (mer) with promoterless luxCDABE from Vibrio fischeri, we have constructed and tested three biosensors for Hg(II). Bioluminescence specified by pRB28, carrying merRo/pT, by pOS14, mediating active transport of Hg(II), and by pOS15, containing an intact mer operon, was measured in rich and minimal media. The highest sensitivities were achieved in minimal medium and were 1, 0.5, and 25 nM Hg(II) for pRB28, pOS14, and pOS15, respectively. The utility of the biosensors in natural waters was demonstrated with freshwater, rain, and estuarine samples supplemented with Hg(II). mer-lux carried by pRB28 and pOS14 responded to Hg(II) in mercury-contaminated water samples collected from a freshwater pond. Semiquantitative analyses based on light emission in samples collected from the inlet (analytically determined total mercury, approximately 20 nM) and outlet (total mercury, approximately 7 nM) of the pond showed bioavailable mercury at approximately 20 and 1 to 2 nM, respectively. Thus, the biosensors described here semiquantitatively detect bioavailable inorganic mercury (at a nanomolar to micromolar concentration range) in contaminated waters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bacterial mercury resistance from atoms to ecosystems
Barkay, T., Miller, S. M., & Summers, A. O. (2003) · FEMS Microbiology Reviews · doi:10.1016/s0168-6445(03)00046-9 · Cited by 1,054
Self-citationWhere microbiology meets microengineering: design and applications of reporter bacteria
van der Meer, J. R., & Belkin, S. (2010) · Nature Reviews Microbiology · doi:10.1038/nrmicro2392 · Cited by 533
Geochemistry of Mercury in the Environment
Fitzgerald, W. F., & Lamborg, C. H. (2014) · Treatise on Geochemistry · doi:10.1016/b978-0-08-095975-7.00904-9 · Cited by 275
Applications of whole-cell bacterial sensors in biotechnology and environmental science
Yagi, K. (2007) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-006-0718-6 · Cited by 254
Detecting adenosine triphosphate in the pericellular space
Falzoni, S., Donvito, G., & Di Virgilio, F. (2013) · Interface Focus · doi:10.1098/rsfs.2012.0101 · Cited by 136
Metadata
- Authors
- Selifonova, O., Burlage, R., & Barkay, T.
- Venue
- Applied and Environmental Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1993-09
- Volume
- 59
- Issue
- 9
- Pages
- 3083-3090
- ISSN
- 0099-2240 (ISSN-L)
- 1098-5336
- OpenAlex
- W1869278765
- Cited by
- 358
- References
- 0
- FWCI
- 4.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bioluminescent sensors for detection of bioavailable Hg(II) in the environment. https://app.cochat.ai/papers/10.1128/aem.59.9.3083-3090.1993
- The paper
- Selifonova, O., Burlage, R., & Barkay, T. (1993). Bioluminescent sensors for detection of bioavailable Hg(II) in the environment. Applied and Environmental Microbiology. https://doi.org/10.1128/aem.59.9.3083-3090.1993
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.