Bioluminescent sensors for detection of bioavailable Hg(II) in the environment
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Biosensors for the detection of pollutants in the environment can complement analytical methods by distinguishing bioavailable from inert, unavailable forms of contaminants. By using fusions of the well-understood Tn21 mercury resistance operon (mer) with promoterless luxCDABE from Vibrio fischeri, we have constructed and tested three biosensors for Hg(II). Bioluminescence specified by pRB28, carrying merRo/pT, by pOS14, mediating active transport of Hg(II), and by pOS15, containing an intact mer operon, was measured in rich and minimal media. The highest sensitivities were achieved in minimal medium and were 1, 0.5, and 25 nM Hg(II) for pRB28, pOS14, and pOS15, respectively. The utility of the biosensors in natural waters was demonstrated with freshwater, rain, and estuarine samples supplemented with Hg(II). mer-lux carried by pRB28 and pOS14 responded to Hg(II) in mercury-contaminated water samples collected from a freshwater pond. Semiquantitative analyses based on light emission in samples collected from the inlet (analytically determined total mercury, approximately 20 nM) and outlet (total mercury, approximately 7 nM) of the pond showed bioavailable mercury at approximately 20 and 1 to 2 nM, respectively. Thus, the biosensors described here semiquantitatively detect bioavailable inorganic mercury (at a nanomolar to micromolar concentration range) in contaminated waters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular Cloning: A Laboratory Manual
Sambrook, J., Fritsch, E., & Maniatis, T. (1989) · UCLA - Biblioteca de Ciencias de la Salud · Cited by 133,589
Experiments in molecular genetics
Miller, J. H. (1972) · Medical Entomology and Zoology · Cited by 27,157
Studies on transformation of Escherichia coli with plasmids
Hanahan, D. (1983) · Journal of Molecular Biology · doi:10.1016/s0022-2836(83)80284-8 · Cited by 11,157
Bloom, N. (1989) · Canadian Journal of Fisheries and Aquatic Sciences · doi:10.1139/f89-147 · Cited by 885
Bloom, N., & Fitzgerald, W. F. (1988) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)80743-6 · Cited by 867
Molecular biology of bacterial bioluminescence
Meighen, E. A. (1991) · Microbiological Reviews · doi:10.1128/mmbr.55.1.123-142.1991 · Cited by 796
Mercury methylation in aquatic systems affected by acid deposition
Gilmour, C. C., & Henry, E. A. (1991) · Environmental Pollution · doi:10.1016/0269-7491(91)90031-q · Cited by 652
Rapid, Sensitive Bioluminescent Reporter Technology for Naphthalene Exposure and Biodegradation
King, J. M., DiGrazia, P. M., Applegate, B. M., Burlage, R. S., Sanseverino, J., Dunbar, P., Larimer, F. W., & Sayler, G. S. (1990) · Science · doi:10.1126/science.249.4970.778 · Cited by 459
Self-citationGene regulation of plasmid- and chromosome-determined inorganic ion transport in bacteria
Silver, S. D., & WALDERHAUG, M. O. (1992) · Microbiological Reviews · doi:10.1128/mmbr.56.1.195-228.1992 · Cited by 424
Total Quantum Flux of Isotropic Sources*
Hastings, J. W., & Weber, G. (1963) · Journal of the Optical Society of America · doi:10.1364/josa.53.001410 · Cited by 403
Cited by
Bacterial mercury resistance from atoms to ecosystems
Barkay, T., Miller, S. M., & Summers, A. O. (2003) · FEMS Microbiology Reviews · doi:10.1016/s0168-6445(03)00046-9 · Cited by 1,054
Self-citationOlaniran, A., Balgobind, A., & Pillay, B. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms140510197 · Cited by 652
D'Souza, S. F. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00125-7 · Cited by 569
Dynamic Oxidation of Gaseous Mercury in the Arctic Troposphere at Polar Sunrise
Lindberg, S. E., Brooks, S., Lin, C.-J., Scott, K. J., Landis, M. S., Stevens, R. K., Goodsite, M., & Richter, A. (2002) · Environmental Science & Technology · doi:10.1021/es0111941 · Cited by 534
Where microbiology meets microengineering: design and applications of reporter bacteria
van der Meer, J. R., & Belkin, S. (2010) · Nature Reviews Microbiology · doi:10.1038/nrmicro2392 · Cited by 533
Daunert, S., Barrett, G., Feliciano, J. S., Shetty, R. S., Shrestha, S., & Smith-Spencer, W. (2000) · Chemical Reviews · doi:10.1021/cr990115p · Cited by 445
Lei, Y., Chen, W., & Mulchandani, A. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.11.065 · Cited by 406
Development and Application of Cell-Based Biosensors
Pancrazio, J. J., Whelan, J. P., Borkholder, D. A., Ma, W., & Stenger, D. A. (1999) · Annals of Biomedical Engineering · doi:10.1114/1.225 · Cited by 391
Impact of metals on the biodegradation of organic pollutants.
Sandrin, T. R., & Maier, R. M. (2003) · Environmental Health Perspectives · doi:10.1289/ehp.5840 · Cited by 386
Effects of dissolved organic carbon and salinity on bioavailability of mercury
Barkay, T., Gillman, M., & Turner, R. R. (1997) · Applied and Environmental Microbiology · doi:10.1128/aem.63.11.4267-4271.1997 · Cited by 362
Self-citationBousse, L. (1996) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(96)01906-5 · Cited by 345
Janata, J., Josowicz, M., Vanýsek, P., & DeVaney, D. M. (1998) · Analytical Chemistry · doi:10.1021/a1980010w · Cited by 330
Barkay, T., & Wagner‐Döbler, I. (2005) · Advances in Applied Microbiology · doi:10.1016/s0065-2164(05)57001-1 · Cited by 315
Self-citationTrace metal speciation and bioavailability in anaerobic digestion: A review
Thanh, P. M., Ketheesan, B., Yan, Z., & Stuckey, D. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2015.12.006 · Cited by 309
Hg(II) sensing based on functionalized carbon dots obtained by direct laser ablation
Gonçalves, H., Jorge, P. A. S., Fernandes, J. R. A., & Esteves da Silva, J. C. G. (2010) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2010.01.031 · Cited by 290
Boyd, E. S., & Barkay, T. (2012) · Frontiers in Microbiology · doi:10.3389/fmicb.2012.00349 · Cited by 286
Self-citationGeochemistry of Mercury in the Environment
Fitzgerald, W. F., & Lamborg, C. H. (2014) · Treatise on Geochemistry · doi:10.1016/b978-0-08-095975-7.00904-9 · Cited by 275
Microbial growth and substrate utilization kinetics
Okpokwasili, G. C., & Nweke, C. O. (2006) · TSpace (University of Toronto) · doi:10.5897/ajb2006.000-5041 · Cited by 255
Applications of whole-cell bacterial sensors in biotechnology and environmental science
Yagi, K. (2007) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-006-0718-6 · Cited by 254
Heitzer, A., Malachowsky, K., Thonnard, J. E., Bienkowski, P. R., White, D. C., & Sayler, G. S. (1994) · Applied and Environmental Microbiology · doi:10.1128/aem.60.5.1487-1494.1994 · Cited by 248
Luminescent bacterial sensor for cadmium and lead
Tauriainen, S., Karp, M., Chang, W., & Virta, M. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(98)00027-x · Cited by 240
Secrets of Soil Survival Revealed by the Genome Sequence of Arthrobacter aurescens TC1
Mongodin, E. F., Shapir, N., Daugherty, S. C., DeBoy, R. T., Emerson, J. B., Shvartzbeyn, A., Radune, D., Vamathevan, J., Riggs, F., Grinberg, V., et al. (2006) · PLoS Genetics · doi:10.1371/journal.pgen.0020214 · Cited by 235
“The bacterium was routinely grown at 30 8C in modified R minimal medium [76] containing 500 lg/g atrazine as the sole nitrogen and carbon source.”
MethodMicrobes and Microbial Technology: Agricultural and Environmental Applications
(2011) · Springer eBooks · doi:10.1007/978-1-4419-7931-5 · Cited by 225
Arthrobacter aurescens TC1 Metabolizes Diverse s -Triazine Ring Compounds
Strong, L. C., Rosendahl, C., Johnson, G., Sadowsky, M. J., & Wackett, L. P. (2002) · Applied and Environmental Microbiology · doi:10.1128/aem.68.12.5973-5980.2002 · Cited by 223
“agar plates (13, 27) containing 500 mg of atrazine per liter (R-ATZ) as the sole”
MethodBiotests and Biosensors for Ecotoxicology of Metal Oxide Nanoparticles: A Minireview
Kahru, A., Dubourguier, H.-C., Blinova, I., Ivask, A., & Kasemets, K. (2008) · Sensors · doi:10.3390/s8085153 · Cited by 219
“Metal-specific recombinant bacterial sensors have been constructed and used for the determination of bioavailable fractions of inorganic mercury [96, 97], organomercurials [98], zinc, cadmium, cobalt and”
BackgroundSticher, P., Jaspers, M. C., Stemmler, K., Harms, H., Zehnder, A. J., & van der Meer, J. R. (1997) · Applied and Environmental Microbiology · doi:10.1128/aem.63.10.4053-4060.1997 · Cited by 207
“Whole-cell biosensors that can detect naphthalene and salicylate (15, 16), toluene (3), and mercury (27) have been developed.”
BackgroundEffects of Halides on Plasmid-Mediated Silver Resistance in Escherichia coli
Gupta, A., Maynes, M., & Silver, S. (1998) · Applied and Environmental Microbiology · doi:10.1128/aem.64.12.5042-5045.1998 · Cited by 203
“These factors, for example, alter the bioavailability of metal ions (1, 3, 15).”
BackgroundIvask, A., Rõlova, T., & Kahru, A. (2009) · BMC Biotechnology · doi:10.1186/1472-6750-9-41 · Cited by 201
“Although the relevance of this bacterium for environmental testing is questionable, it has been widely used in the construction of various bacterial sensors [9,10,12,14,17], mainly due to its compatibility with the chemical-response elements used.”
BackgroundDissolved Organic Matter Kinetically Controls Mercury Bioavailability to Bacteria
Chiasson-Gould, S. A., Blais, J. M., & Poulain, A. J. (2014) · Environmental Science & Technology · doi:10.1021/es4038484 · Cited by 198
Applegate, B. M., Kehrmeyer, S. R., & Sayler, G. S. (1998) · Applied and Environmental Microbiology · doi:10.1128/aem.64.7.2730-2735.1998 · Cited by 195
A review of environmental applications of bioluminescence measurements
Steinberg, S. M., Poziomek, E. J., Engelmann, W. H., & Rogers, K. R. (1995) · Chemosphere · doi:10.1016/0045-6535(95)00087-o · Cited by 188
Application of a mer-lux biosensor for estimating bioavailable mercury in soil
Rasmussen, L. D., Sørensen, S. J., Turner, R. R., & Barkay, T. (2000) · Soil Biology and Biochemistry · doi:10.1016/s0038-0717(99)00190-x · Cited by 172
“Growth and preparation of cells for mer-lux assays were as described by Selifonova et al. (1993).”
Self-citationStrong, L. C., McTavish, H., Sadowsky, M. J., & Wackett, L. P. (2000) · Environmental Microbiology · doi:10.1046/j.1462-2920.2000.00079.x · Cited by 170
“Modi®ed R-minimal medium (Eaton and Ribbons, 1982; Selifonova et al., 1993) plates containing 500 p.”
MethodNies, D. H. (2000) · Extremophiles · doi:10.1007/s007920050140 · Cited by 169
“Bacteria harboring mer-lux fusions were able to sense Hg21 in the environment down to “chemical” concentrations of 0.5nM (Selifonova et al. 1993).”
Effect of pH on Mercury Uptake by an Aquatic Bacterium: Implications for Hg Cycling
Kelly, C. A., Rudd, J. W. M., & Holoka, M. H. (2003) · Environmental Science & Technology · doi:10.1021/es026366o · Cited by 163
Illuminating the detection chain of bacterial bioreporters
Van Der Meer, J. R., Tropel, D., & Jaspers, M. (2004) · Environmental Microbiology · doi:10.1111/j.1462-2920.2004.00655.x · Cited by 163
“, 1995) than in an equivalent luxbased bioreporter (Selifonova et al., 1993; Rasmussen et al., 1997).”
BackgroundDetecting adenosine triphosphate in the pericellular space
Falzoni, S., Donvito, G., & Di Virgilio, F. (2013) · Interface Focus · doi:10.1098/rsfs.2012.0101 · Cited by 136
Bioluminescent bacteria: lux genes as environmental biosensors
Nunes-Halldorson, V. D. S., & Duran, N. L. (2003) · Brazilian Journal of Microbiology · doi:10.1590/s1517-83822003000200001 · Cited by 65
Wlodkowic, D., & Karpiński, T. M. (2021) · Sensors · doi:10.3390/s21217028 · Cited by 28
“Already in the early 1990s, a Tn21 mercury resistance operon (mer) and naphthalene and salicylate catabolism promoter (nahG) were fused with promoterless luxCDABE to create biosensors for mercury and naphthalene pollution [72,74].”
Background
Metadata
- Authors
- Selifonova, O., Burlage, R., & Barkay, T.
- Venue
- Applied and Environmental Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1993-09
- Volume
- 59
- Issue
- 9
- Pages
- 3083-3090
- ISSN
- 0099-2240 (ISSN-L)
- 1098-5336
- OpenAlex
- W1869278765
- Cited by
- 358
- References
- 33
- FWCI
- 4.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.