Development and characterization of a whole-cell bioluminescent sensor for bioavailable middle-chain alkanes in contaminated groundwater samples
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
A microbial whole-cell biosensor was developed, and its potential to measure water-dissolved concentrations of middle-chain-length alkanes and some related compounds by bioluminescence was characterized. The biosensor strain Escherichia coli DH5 alpha(pGEc74, pJAMA7) carried the regulatory gene alkS from Pseudomonas oleovorans and a transcriptional fusion of PalkB from the same strain with the promoterless luciferase luxAB genes from Vibrio harveyi on two separately introduced plasmids. In standardized assays, the biosensor cells were readily inducible with octane, a typical inducer of the alk system. Light emission after induction periods of more than 15 min correlated well with octane concentration. In well-defined aqueous samples, there was a linear relationship between light output and octane concentrations between 24 and 100 nM. The biosensor responded to middle-chain-length alkanes but not to alicyclic or aromatic compounds. In order to test its applicability for analyzing environmentally relevant samples, the biosensor was used to detect the bioavailable concentration of alkanes in heating oil-contaminated groundwater samples. By the extrapolation of calibrated light output data to low octane concentrations with a hyperbolic function, a total inducer concentration of about 3 nM in octane equivalents was estimated. The whole-cell biosensor tended to underestimate the alkane concentration in the groundwater samples by about 25%, possibly because of the presence of unknown inhibitors. This was corrected for by spiking the samples with a known amount of an octane standard. Biosensor measurements of alkane concentrations were further verified by comparing them with the results of chemical analyses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular cloning: A laboratory manual
Deininger, P. (1990) · Analytical Biochemistry · doi:10.1016/0003-2697(90)90595-z · Cited by 84,682
Mechanisms of Slow Sorption of Organic Chemicals to Natural Particles
Pignatello, J. J., & Xing, B. (1996) · Environmental Science & Technology · doi:10.1021/es940683g · Cited by 1,718 · cited 1×
“In general, the bioavailability of hydrophobic compounds is determined by their sorption characteristics (12, 13, 22, 23, 25) and dissolution or partitioning rates (8, 13, 32, 33) and by transport processes to the microbial cell (12, 14).”
BackgroundHerrero, M., de Lorenzo, V, & Timmis, K. N. (1990) · Journal of Bacteriology · doi:10.1128/jb.172.11.6557-6567.1990 · Cited by 1,586
Rapid, Sensitive Bioluminescent Reporter Technology for Naphthalene Exposure and Biodegradation
King, J. M., DiGrazia, P. M., Applegate, B. M., Burlage, R. S., Sanseverino, J., Dunbar, P., Larimer, F. W., & Sayler, G. S. (1990) · Science · doi:10.1126/science.249.4970.778 · Cited by 459 · cited 1×
“Such a biosensor system is the extensively studied naphthalene/salicylate-degrading sensor strain Pseudomonas fluorescence HK44 (4, 15, 16, 20).”
BackgroundPlasmid vectors for the selection of promoters
Brosius, J. (1984) · Gene · doi:10.1016/0378-1119(84)90136-7 · Cited by 423
Bioluminescent sensors for detection of bioavailable Hg(II) in the environment
Selifonova, O., Burlage, R., & Barkay, T. (1993) · Applied and Environmental Microbiology · doi:10.1128/aem.59.9.3083-3090.1993 · Cited by 358 · cited 1×
“Whole-cell biosensors that can detect naphthalene and salicylate (15, 16), toluene (3), and mercury (27) have been developed.”
BackgroundRapid and sensitive pollutant detection by induction of heat shock gene-bioluminescence gene fusions
Van Dyk, T. K., Majarian, W. R., Konstantinov, K. B., Young, R. M., Dhurjati, P. S., & LaRossa, R. A. (1994) · Applied and Environmental Microbiology · doi:10.1128/aem.60.5.1414-1420.1994 · Cited by 298 · cited 1×
“Other biosensor strains were constructed to detect toxic compounds, generally by coupling the lux genes with a stress-inducible promoter (34).”
BackgroundRole of dissolution rate and solubility in biodegradation of aromatic compounds
Stucki, G., & Alexander, M. (1987) · Applied and Environmental Microbiology · doi:10.1128/aem.53.2.292-297.1987 · Cited by 249
Heitzer, A., Malachowsky, K., Thonnard, J. E., Bienkowski, P. R., White, D. C., & Sayler, G. S. (1994) · Applied and Environmental Microbiology · doi:10.1128/aem.60.5.1487-1494.1994 · Cited by 248
Rates of dissolution and biodegradation of water-insoluble organic compounds
Thomas, J. M., Yordy, J. R., Amador, J. A., & Alexander, M. (1986) · Applied and Environmental Microbiology · doi:10.1128/aem.52.2.290-296.1986 · Cited by 215 · cited 1×
“In general, the bioavailability of hydrophobic compounds is determined by their sorption characteristics (12, 13, 22, 23, 25) and dissolution or partitioning rates (8, 13, 32, 33) and by transport processes to the microbial cell (12, 14).”
Background
Cited by
Recent Advances in Petroleum Microbiology
Van Hamme, J. D., Singh, A., & Ward, O. P. (2003) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.67.4.503-549.2003 · Cited by 1,477
Degradation of alkanes by bacteria
Rojo, F. (2009) · Environmental Microbiology · doi:10.1111/j.1462-2920.2009.01948.x · Cited by 822
Semple, K. T., Morriss, A. W. J., & Paton, G. I. (2003) · European Journal of Soil Science · doi:10.1046/j.1351-0754.2003.0564.x · Cited by 614
Rojo, F. (2010) · FEMS Microbiology Reviews · doi:10.1111/j.1574-6976.2010.00218.x · Cited by 539
Where microbiology meets microengineering: design and applications of reporter bacteria
van der Meer, J. R., & Belkin, S. (2010) · Nature Reviews Microbiology · doi:10.1038/nrmicro2392 · Cited by 533
Self-citationBiosensors as useful tools for environmental analysis and monitoring
Rodriguez-Mozaz, S., Lopez de Alda, M. J., & Barceló, D. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0574-3 · Cited by 451
Daunert, S., Barrett, G., Feliciano, J. S., Shetty, R. S., Shrestha, S., & Smith-Spencer, W. (2000) · Chemical Reviews · doi:10.1021/cr990115p · Cited by 445
Development and Application of Cell-Based Biosensors
Pancrazio, J. J., Whelan, J. P., Borkholder, D. A., Ma, W., & Stenger, D. A. (1999) · Annals of Biomedical Engineering · doi:10.1114/1.225 · Cited by 391
Bacterial Transcriptional Regulators for Degradation Pathways of Aromatic Compounds
Tropel, D., & van der Meer, J. R. (2004) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.68.3.474-500.2004 · Cited by 384
Self-citationGui, Q., Lawson, T., Shan, S., Yan, L., & Liu, Y. (2017) · Sensors · doi:10.3390/s17071623 · Cited by 347
(Bio)sensors for measurement of analytes implicated in food safety: a review
Patel, P. D. (2002) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(01)00136-4 · Cited by 314
Biosensors for wastewater monitoring: A review
Ejeian, F., Etedali, P., Mansouri-Tehrani, H.-A., Soozanipour, A., Low, Z.-X., Asadnia, M., Taheri-Kafrani, A., & Razmjou, A. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.07.019 · Cited by 287
Applications of whole-cell bacterial sensors in biotechnology and environmental science
Yagi, K. (2007) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-006-0718-6 · Cited by 254
Huang, C.-W., Lin, C., Nguyen, M. K., Hussain, A., Bui, X.-T., & Ngo, H. H. (2023) · Bioengineered · doi:10.1080/21655979.2022.2095089 · Cited by 227
Enzymes and genes involved in aerobic alkane degradation
Wang, W., & Shao, Z. (2013) · Frontiers in Microbiology · doi:10.3389/fmicb.2013.00116 · Cited by 213
“An AlkS-dependent reporter system based on a PalkB-luxAB fusion showed that C5–C10 alkanes are efficient activators of the AlkS regulator (Sticher et al., 1997).”
BackgroundWhole-cell living biosensors—are they ready for environmental application?
Harms, H., Wells, M. C., & van der Meer, J. R. (2006) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-006-0319-4 · Cited by 197
“1994) or middle-chain-length alkanes as indicators of contamination with fuels (Sticher et al. 1997).”
BackgroundSelf-citationIlluminating the detection chain of bacterial bioreporters
Van Der Meer, J. R., Tropel, D., & Jaspers, M. (2004) · Environmental Microbiology · doi:10.1111/j.1462-2920.2004.00655.x · Cited by 163
“for heavy metals and organic pollutants) display background expression levels of about 1–5% of the maximum response (Sticher et al., 1997; Jaspers et al., 2000b; 2001; Stocker et al., 2003).”
BackgroundSelf-citationBioluminescent bacteria: lux genes as environmental biosensors
Nunes-Halldorson, V. D. S., & Duran, N. L. (2003) · Brazilian Journal of Microbiology · doi:10.1590/s1517-83822003000200001 · Cited by 65
Metadata
- Authors
- Sticher, P., Jaspers, M. C., Stemmler, K., Harms, H., Zehnder, A. J., & van der Meer, J. R.
- Venue
- Applied and Environmental Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1997-10
- Volume
- 63
- Issue
- 10
- Pages
- 4053-4060
- ISSN
- 0099-2240 (ISSN-L)
- 1098-5336
- OpenAlex
- W1748737364
- Cited by
- 207
- References
- 23
- FWCI
- 2.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.