Simultaneous Detection of 15 Human Cytokines in a Single Sample of Stimulated Peripheral Blood Mononuclear Cells
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Cytokines secreted by cells of the immune system can alter the behavior and properties of immune or other cells. At a site of inflammation, sets of cytokines interact with immune cells, and their combined effect is often more important than the function of one isolated component. Conventional techniques, such as enzyme-linked immunosorbent assays, generally require large quantities of cells to characterize a complete cytokine profile of activated lymphocytes. The Bio-Plex system from Bio-Rad Laboratories combines the principle of a sandwich immunoassay with the Luminex fluorescent-bead-based technology. We developed a multiplex cytokine assay to detect different cytokines simultaneously in culture supernatant of human peripheral blood mononuclear cells stimulated with antigen and with mitogen. Fifteen human cytokines (interleukin 1α [IL-1α], IL-1β, IL-2, IL-4, IL-5, IL-6, IL-8, IL-10, IL-12p70, IL-13, IL-15, IL-17, IL-18, gamma interferon, and tumor necrosis factor alpha) were validated with a panel of healthy individuals, rheumatoid arthritis patients, and juvenile idiopathic arthritis patients. Comparing the multiplex assay with a regular enzyme-linked immunosorbent assay technique with this donor panel resulted in correlation coefficients for all cytokines ranging from 0.75 to 0.99. Intra-assay variance proved to be less then 10%, whereas interassay variability ranged between 10 and 22%. This multiplex system proved to be a powerful tool in the quantitation of cytokines. It will provide a more complete picture in differences between activated lymphocyte cytokine profiles from healthy individuals and those from patients with chronic inflammatory diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multiplexed particle-based flow cytometric assays
Vignali, D. A. A. (2000) · Journal of Immunological Methods · doi:10.1016/s0022-1759(00)00238-6 · Cited by 913
Advanced multiplexed analysis with the FlowMetrix system.
Fulton, R. J., McDade, R. L., Smith, P. L., Kienker, L. J., & Kettman, J. R. (1997) · PubMed · Cited by 704
Advanced multiplexed analysis with the FlowMetrixTM system
Fulton, R. J., McDade, R. L., Smith, P. L., Kienker, L. J., & Kettman, J. R. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.9.1749 · Cited by 650
Prussin, C., & Metcalfe, D. D. (1995) · Journal of Immunological Methods · doi:10.1016/0022-1759(95)00209-x · Cited by 458
The role of lymphocytes in allergic disease
Romagnani, S. (2000) · Journal of Allergy and Clinical Immunology · doi:10.1067/mai.2000.104575 · Cited by 446
Simultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay
Carson, R. T., & Vignali, D. A. A. (1999) · Journal of Immunological Methods · doi:10.1016/s0022-1759(99)00069-1 · Cited by 402
Role of cytokines in determining T-lymphocyte function
O'Garra, A., & Murphy, K. (1994) · Current Opinion in Immunology · doi:10.1016/0952-7915(94)90128-7 · Cited by 393
Cook, E. B., Stahl, J. L., Lowe, L., Chen, R., Morgan, E., Wilson, J., Varro, R., Chan, A., Graziano, F. M., & Barney, N. P. (2001) · Journal of Immunological Methods · doi:10.1016/s0022-1759(01)00407-0 · Cited by 285
Kellar, K. L., Kalwar, R. R., Dubois, K. A., Crouse, D., Chafin, W. D., & Kane, B.-E. (2001) · Cytometry · doi:10.1002/1097-0320(20010901)45:1<27::aid-cyto1141>3.0.co;2-i · Cited by 194
Simultaneous quantification of proinflammatory cytokines in human plasma using the LabMAP™ assay
Prabhakar, U., Eirikis, E., & Davis, H. M. (2002) · Journal of Immunological Methods · doi:10.1016/s0022-1759(01)00543-9 · Cited by 184
Pickering, J. W., Martins, T. B., Greer, R. W., Schroder, M. C., Astill, M. E., Litwin, C. M., Hildreth, S. W., & Hill, H. R. (2002) · American Journal of Clinical Pathology · doi:10.1309/lmch-c4q2-vfl9-3t1a · Cited by 177
Flow Cytometric Platform for High-Throughput Single Nucleotide Polymorphism Analysis
Taylor, J. D., Briley, D., Nguyen, Q., Long, K., Iannone, M. A., Li, M.-S., Ye, F., Afshari, A., Lai, E., Wagner, M., et al. (2001) · BioTechniques · doi:10.2144/01303dd04 · Cited by 173
BADGE, BeadsArray for the Detection of Gene Expression, a High-Throughput Diagnostic Bioassay
Yang, L., Tran, D. K., & Wang, X. (2001) · Genome Research · doi:10.1101/gr.190901 · Cited by 120
Hennig, C., Rink, L., Fagin, U., Jabs, W. J., & Kirchner, H. (2000) · Journal of Immunological Methods · doi:10.1016/s0022-1759(99)00206-9 · Cited by 117
Martins, T. B. (2002) · Clinical and Vaccine Immunology · doi:10.1128/cdli.9.1.41-45.2002 · Cited by 95
Multiplexed Quantification of Human IgG, IgA, and IgM with the FlowMetrixTM System,
Gordon, R. F., & McDade, R. L. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.9.1799 · Cited by 63
Hidaka, T., Suzuki, K., Kawakami, M., Okada, M., Kataharada, K., Shinohara, T., Takamizawa‐Matsumoto, M., & Ohsuzu, F. (2001) · Journal of Clinical Apheresis · doi:10.1002/jca.1016 · Cited by 59
Kardar, G., Jeddi‐Tehrani, M., & Shokri, F. (2002) · Scandinavian Journal of Immunology · doi:10.1046/j.1365-3083.2002.01057.x · Cited by 57
Multiplexed quantification of human IgG, IgA, and IgM with the FlowMetrix system.
Gordon, R. F., & McDade, R. L. (1997) · PubMed · Cited by 54
Camilla, C., Mély, L., Magnan, A., Casano, B., Prato, S., Debono, S., Montero, F., Defoort, J.-P., Martin, M. C. D., & Fert, V. (2001) · Clinical and Diagnostic Laboratory Immunology · doi:10.1128/cdli.8.4.776-784.2001 · Cited by 44
Cited by
Long‐term expanding human airway organoids for disease modeling
Sachs, N., Papaspyropoulos, A., Zomer‐van Ommen, D. D., Heo, I., Böttinger, L., Klay, D., Weeber, F., Huelsz‐Prince, G., Iakobachvili, N., Amatngalim, G. D., et al. (2019) · The EMBO Journal · doi:10.15252/embj.2018100300 · Cited by 1,082
Guidelines for the use of flow cytometry and cell sorting in immunological studies (second edition)
Cossarizza, A., Chang, H., Radbruch, A., Acs, A., Adam, D., Adam‐Klages, S., Agace, W. W., Aghaeepour, N., Akdis, M., Allez, M., et al. (2019) · European Journal of Immunology · doi:10.1002/eji.201970107 · Cited by 979
Distinct Cytokine Patterns Identified from Multiplex Profiles of Murine DSS and TNBS-Induced Colitis
Alex, P., Zachos, N. C., Nguyen, T., Gonzales, L., Chen, T.-E., Conklin, L. S., Centola, M., & Li, X. (2009) · Inflammatory Bowel Diseases · doi:10.1002/ibd.20753 · Cited by 750
Cytokine profiles as markers of disease severity in sepsis: a multiplex analysis
Bozza, F. A., Salluh, J. I., Japiassu, A. M., Soares, M., Assis, E. F., Gomes, R. N., Bozza, M. T., Castro-Faria-Neto, H. C., & Bozza, P. T. (2007) · Critical Care · doi:10.1186/cc5783 · Cited by 740
Multiplexed protein measurement: technologies and applications of protein and antibody arrays
Kingsmore, S. F. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd2006 · Cited by 715
Metadata
- Authors
- de Jager, W., te Velthuis, H., Prakken, B. J., Kuis, W., & Rijkers, G. T.
- Venue
- Clinical and Vaccine Immunology
- Publisher
- American Society for Microbiology
- Published
- 2003-01
- Volume
- 10
- Issue
- 1
- Pages
- 133-139
- ISSN
- 1556-679X (ISSN-L)
- 1556-6811
- OpenAlex
- W2103097055
- Cited by
- 568
- References
- 20
- FWCI
- 12.55
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.