Levels of Cytokines and Immune Activation Markers in Plasma in Human Immunodeficiency Virus Infection: Quality Control Procedures

Open access
Aziz, Najib, Nishanian, Parunag, Fahey, John L. · 1998 · Clinical Diagnostic Laboratory Immunology
Cited by 59

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Procedures for quality control (QC) in a laboratory that concentrates on cytokine and soluble marker measurements in biological fluids are outlined. Intra-assay, interassay, and interlaboratory experiences are presented. Plasma and serum β2-microglobulin (β2M) and neopterin test data are presented in greatest detail, along with substantial tumor necrosis factor alpha (TNF-α), gamma interferon, soluble interleukin-2 receptor-α (sIL-2Rα), sTNF-RII, IL-4, and IL-6 data. Recommended QC procedures for cytokine and soluble-marker testing include replicate testing of two or more reference samples provided by the kit manufacturer, replicate testing of in-house frozen reference QC samples that represent normal and abnormal analyte contents, retesting 15 to 20% of randomly selected samples, and comparing normal reference ranges each year. Also, eight cytokines and soluble markers were evaluated in human immunodeficiency virus (HIV)-seronegative and HIV-seropositive individuals stratified on the basis of CD4 T-cell numbers. Levels of some but not all cytokines in serum increased in HIV infection. There was a tendency for cytokines to increase with more advanced disease, defined by reduced CD4 T-cell numbers. Cytokine changes did not relate closely to CD4 level, indicating that separate information was provided by the measurements of TNF-α, sTNF-RII, sIL-2Rα, β2M, and neopterin. Serum IL-4 and TNF-α levels were not increased. The quality of laboratory data can impact on clinical relevance. Interlaboratory comparisons revealed substantial differences at some sites and documented the need for external proficiency-testing quality assurance programs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/cdli.5.6.755-761.1998

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Measuring cytokine levels in blood

    Thavasu, P. W., Longhurst, S., Joel, S. P., Slevin, M. L., & Balkwill, F. R. (1992) · Journal of Immunological Methods · doi:10.1016/0022-1759(92)90313-i · Cited by 241 · cited 1×

    “Variations in results have been shown to be due at least in part to differences in the standards used in the assays (16, 26, 30–33, 40) or in sample collection, processing, and storage (9, 27, 41, 45).”
    Result

Show all 1 references

Cited by

Metadata

Authors
Aziz, N., Nishanian, P., & Fahey, J. L.
Venue
Clinical Diagnostic Laboratory Immunology
Published
1998-11
Volume
5
Issue
6
Pages
755-761
ISSN
  • 1071-412X (ISSN-L)
  • 1098-6588
OpenAlex
W2147006136
Cited by
59
References
1
FWCI
1.20
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.