The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Magnetic separation techniques in diagnostic microbiology
Open accessAbstract
The principles of magnetic separation aided by antibodies or other specific binding molecules have been used for isolation of specific viable whole organisms, antigens, or nucleic acids. Whereas growth on selective media may be helpful in isolation of a certain bacterial species, immunomagnetic separation (IMS) technology can isolate strains possessing specific and characteristic surface antigens. Further separation, cultivation, and identification of the isolate can be performed by traditional biochemical, immunologic, or molecular methods. PCR can be used for amplification and identification of genes of diagnostic importance for a target organism. The combination of IMS and PCR reduces the assay time to several hours while increasing both specificity and sensitivity. Use of streptavidin-coated magnetic beads for separation of amplified DNA fragments, containing both biotin and a signal molecule, has allowed for the conversion of the traditional PCR into an easy-to-read microtiter plate format. The bead-bound PCR amplicons can also easily be sequenced in an automated DNA sequencer. The latter technique makes it possible to obtain sequence data of 300 to 600 bases from 20 to 30 strains, starting with clinical samples, within 12 to 24 h. Sequence data can be used for both diagnostic and epidemiologic purposes. IMS has been demonstrated to be a useful method in diagnostic microbiology. Most recent publications describe IMS as a method for enhancing the specificity and sensitivity of other detection systems, such as PCR, and providing considerable savings in time compared with traditional diagnostic systems. The relevance to clinical diagnosis has, however, not yet been fully established for all of these new test principles. In the case of PCR, for example, the presence of specific DNA in a food sample does not demonstrate the presence of a live organism capable of inducing a disease. However, all tests offering increased sensitivity and specificity of detection, combined with reduced time of analysis, have to be seriously evaluated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Identification of the Uncultured Bacillus of Whipple’s Disease
Relman, D. A., Schmidt, T. M., MacDermott, R. P., & Falkow, S. (1992) · New England Journal of Medicine · doi:10.1056/nejm199207303270501 · Cited by 1,157
Direct solid phase sequencing of genomic and plasmid DNA using magnetic beads as solid support
Hultman, T., Stahl, S., Homes, E., & Uhlén, M. (1989) · Nucleic Acids Research · doi:10.1093/nar/17.13.4937 · Cited by 723
Self-citationPreparation and application of new monosized polymer particles
Ugelstad, J., Berge, A., Ellingsen, T., Schmid, R., Nilsen, T.-N., Mørk, P. C., Stenstad, P., Hornes, E., & Olsvik, Ø. (1992) · Progress in Polymer Science · doi:10.1016/0079-6700(92)90017-s · Cited by 459
Self-citationWilde, J. A., Eiden, J. J., & Yolken, R. H. (1990) · Journal of Clinical Microbiology · doi:10.1128/jcm.28.6.1300-1307.1990 · Cited by 280
Fields, P. I., Popovic, T., Wachsmuth, K., & Olsvik, O. (1992) · Journal of Clinical Microbiology · doi:10.1128/jcm.30.8.2118-2121.1992 · Cited by 240
Self-citationWidjojoatmodjo, M. N., Fluit, A. C., Torensma, R., Verdonk, G. P., & Verhoef, J. (1992) · Journal of Clinical Microbiology · doi:10.1128/jcm.30.12.3195-3199.1992 · Cited by 219
Uhlen, M. (1989) · Nature · doi:10.1038/340733a0 · Cited by 219
Polymerase chain reaction: trenches to benches
Persing, D. H. (1991) · Journal of Clinical Microbiology · doi:10.1128/jcm.29.7.1281-1285.1991 · Cited by 211
Krogfelt, K. A. (1991) · Clinical Infectious Diseases · doi:10.1093/clinids/13.4.721 · Cited by 197
Kapperud, G., Vardund, T., Skjerve, E., Hornes, E., & Michaelsen, T. E. (1993) · Applied and Environmental Microbiology · doi:10.1128/aem.59.9.2938-2944.1993 · Cited by 170
Self-citation
Cited by
Synthesis and surface engineering of iron oxide nanoparticles for biomedical applications
Gupta, A. K., & Gupta, M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.10.012 · Cited by 6,771
Electrochemiluminescence (ECL)
Richter, M. M. (2004) · Chemical Reviews · doi:10.1021/cr020373d · Cited by 2,588
Neuberger, T., Schöpf, B., Hofmann, H., Hofmann, M., & von Rechenberg, B. (2005) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2005.01.064 · Cited by 1,728
Huang, X., Jain, P. K., El-Sayed, I. H., & El-Sayed, M. A. (2007) · Nanomedicine · doi:10.2217/17435889.2.5.681 · Cited by 1,503
High-Efficiency Intracellular Magnetic Labeling with Novel Superparamagnetic-Tat Peptide Conjugates
Josephson, L., Tung, C.-H., Moore, A., & Weissleder, R. (1999) · Bioconjugate Chemistry · doi:10.1021/bc980125h · Cited by 882
Microfluidic Applications of Magnetic Particles for Biological Analysis and Catalysis
Gijs, M. A. M., Lacharme, F., & Lehmann, U. (2010) · Chemical Reviews · doi:10.1021/cr9001929 · Cited by 679
Use of magnetic techniques for the isolation of cells
Šafařı́k, I., & Šafařı́ková, M. (1999) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(98)00338-7 · Cited by 617
Magnetic particles for the separation and purification of nucleic acids
Berensmeier, S. (2006) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-006-0675-0 · Cited by 593
Magnetic nanoparticles with dual functional properties: Drug delivery and magnetic resonance imaging
Jain, T. K., Richey, J., Strand, M., Leslie-Pelecky, D. L., Flask, C. A., & Labhasetwar, V. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.07.004 · Cited by 491
Hong, X., Gao, X., & Jiang, L. (2007) · Journal of the American Chemical Society · doi:10.1021/ja065537c · Cited by 442
Morel, A.-L., Nikitenko, S. I., Gionnet, K., Wattiaux, A., Lai-Kee-Him, J., Labrugere, C., Chevalier, B., Deleris, G., Petibois, C., Brisson, A., et al. (2008) · ACS Nano · doi:10.1021/nn800091q · Cited by 418
Magnetic Iron Oxide Nanoparticle (IONP) Synthesis to Applications: Present and Future
Ajinkya, N., Yu, X., Kaithal, P., Luo, H., Somani, P., & Ramakrishna, S. (2020) · Materials · doi:10.3390/ma13204644 · Cited by 362
Horák, D., Babič, M., Macková, H., & Beneš, M. J. (2007) · Journal of Separation Science · doi:10.1002/jssc.200700088 · Cited by 342
Gupta, A. K., & Curtis, A. S. G. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.095 · Cited by 302
Magnetic polymer beads: Recent trends and developments in synthetic design and applications
Philippova, O., Barabanova, A., Molchanov, V., & Khokhlov, A. (2011) · European Polymer Journal · doi:10.1016/j.eurpolymj.2010.11.006 · Cited by 292
Poly(l-lysine)-Modified Iron Oxide Nanoparticles for Stem Cell Labeling
Babič, M., Horák, D., Trchová, M., Jendelová, P., Glogarová, K., Lesný, P., Herynek, V., Hájek, M., & Syková, E. (2008) · Bioconjugate Chemistry · doi:10.1021/bc700410z · Cited by 291
Drug loaded magnetic nanoparticles for cancer therapy
Jurgons, R., Seliger, C., Hilpert, A., Trahms, L., Odenbach, S., & Alexiou, C. (2006) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/18/38/s24 · Cited by 281
Nano-magnetic particles used in biomedicine: Core and coating materials
Karimi, Z., Karimi, L., & Shokrollahi, H. (2013) · Materials Science and Engineering: C · doi:10.1016/j.msec.2013.01.045 · Cited by 276
Magnetic targeting for site-specific drug delivery: applications and clinical potential
Polyak, B., & Friedman, G. (2009) · Expert Opinion on Drug Delivery · doi:10.1517/17425240802662795 · Cited by 260
Schlenk, F., Werner, S., Rabel, M., Jacobs, F., Bergemann, C., Clement, J. H., & Fischer, D. (2017) · Archives of Toxicology · doi:10.1007/s00204-017-1968-z · Cited by 51
Metadata
- Authors
- Olsvik, O., Popovic, T., Skjerve, E., Cudjoe, K. S., Hornes, E., Ugelstad, J., & Uhlén, M.
- Venue
- Clinical Microbiology Reviews
- Publisher
- American Society for Microbiology
- Published
- 1994-01
- Volume
- 7
- Issue
- 1
- Pages
- 43-54
- ISSN
- 0893-8512 (ISSN-L)
- 1098-6618
- OpenAlex
- W1915493158
- Cited by
- 504
- References
- 38
- FWCI
- 12.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.