Antibodies to Plasmodium falciparum are classically measured using the enzyme-linked immunosorbent assay (ELISA). Although highly sensitive, this technique is labor-intensive when large numbers of samples must be screened against multiple antigens. The suspension array technology (SAT) might be an alterative to ELISA, as it allows measurement of antibodies against multiple antigens simultaneously with a small volume of sample. This study sought to adapt the new SAT multiplex system for measuring antibodies against nine malarial vaccine candidate antigens, including recombinant proteins from two variants of merozoite surface protein 1, two variants of apical merozoite antigen 1, erythrocyte binding antigen 175, merozoite surface protein 3, and peptides from the circumsporozoite protein, ring erythrocyte surface antigen, and liver-stage antigen 1. Various concentrations of the antigens were coupled to microspheres with different spectral addresses, and plasma samples from Cameroonian adults were screened by SAT in mono- and multiplex formats and by ELISA. Optimal amounts of protein required to perform the SAT assay were 10- to 100-fold less than that needed for ELISA. Excellent agreement was found between the single and multiplex formats ( R ≥ 0.96), even when two variants of the same antigen were used. The multiplex assay was rapid, reproducible, required less than 1 μl of plasma, and had a good correlation with ELISA. Thus, SAT provides an important new tool for studying the immune response to malaria rapidly and efficiently in large populations, even when the amount of plasma available is limited, e.g., in studies of neonates or finger-prick blood.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Multiplexed particle-based flow cytometric assays
Vignali, D. A. A. (2000) · Journal of Immunological Methods · doi:10.1016/s0022-1759(00)00238-6 · Cited by 913 · cited 1×
“The use of a filter plate is believed to play a role in the increase in sensitivity (16).”
BackgroundBouharoun-Tayoun, H., Attanath, P., Sabchareon, A., Chongsuphajaisiddhi, T., & Druilhe, P. (1990) · The Journal of experimental medicine · doi:10.1084/jem.172.6.1633 · Cited by 544 · cited 1×
“Individuals living in areas where malaria is transmitted often become immune to the disease, with antibodies (Abs) being an important component of immunity (2).”
BackgroundSelf-citationSimultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay
Carson, R. T., & Vignali, D. A. A. (1999) · Journal of Immunological Methods · doi:10.1016/s0022-1759(99)00069-1 · Cited by 402 · cited 4×
“The SAT has a sensitivity equal to, or better than, ELISA for measuring cytokines (6) and has been reported to have a higher dynamic range (3).”
BackgroundInfluentialSuspension array technology: evolution of the flat-array paradigm
Nolan, J. P., & Sklar, L. A. (2002) · Trends in Biotechnology · doi:10.1016/s0167-7799(01)01844-3 · Cited by 349 · cited 1×
“Flow cytometry was originally used to study whole cells, organelles, or nuclei (5), but it can also measure biological reactions on the surface of solid fluorospheres using suspension array technology (SAT) (10, 11, 15).”
BackgroundOpalka, D., Lachman, C. E., MacMullen, S. A., Jansen, K. U., Smith, J. F., Chirmule, N., & Esser, M. T. (2003) · Clinical and Vaccine Immunology · doi:10.1128/cdli.10.1.108-115.2003 · Cited by 276
Kellar, K. L., Kalwar, R. R., Dubois, K. A., Crouse, D., Chafin, W. D., & Kane, B.-E. (2001) · Cytometry · doi:10.1002/1097-0320(20010901)45:1<27::aid-cyto1141>3.0.co;2-i · Cited by 194 · cited 1×
“The SAT has a sensitivity equal to, or better than, ELISA for measuring cytokines (6) and has been reported to have a higher dynamic range (3).”
BackgroundPickering, J. W., Martins, T. B., Greer, R. W., Schroder, M. C., Astill, M. E., Litwin, C. M., Hildreth, S. W., & Hill, H. R. (2002) · American Journal of Clinical Pathology · doi:10.1309/lmch-c4q2-vfl9-3t1a · Cited by 177 · cited 2×
“The technique has been used to measure Ab levels to protein Ags of several microbes (12, 14, 17) but not for more complex parasites.”
MethodResultProbability binning comparison: A metric for quantitating univariate distribution differences
Roederer, M., Treister, A., Moore, W., & Herzenberg, L. A. (2001) · Cytometry · doi:10.1002/1097-0320(20010901)45:1<79::aid-cyto1147>3.0.co;2-q · Cited by 173
Lal, G., Balmer, P., Stanford, E., Martin, S., Warrington, R., & Borrow, R. (2004) · Journal of Immunological Methods · doi:10.1016/j.jim.2004.11.006 · Cited by 142 · cited 2×
“Multiplex assays have been developed for detecting Abs to combinations of viral and bacterial pathogens (7, 13) and to different bacterial serotypes (8, 9).”
MethodResultPickering, J. W., Martins, T. B., Schroder, M. C., & Hill, H. R. (2002) · Clinical and Vaccine Immunology · doi:10.1128/cdli.9.4.872-876.2002 · Cited by 131 · cited 5×
“The shorter incubation and, thus, shorter total assay time of the SAT assay has been described previously (13).”
BackgroundMethodResultInfluential
Cited by
Doolan, D. L., Dobaño, C., & Baird, J. K. (2009) · Clinical Microbiology Reviews · doi:10.1128/cmr.00025-08 · Cited by 1,301
“At between 4 and 10 months of age many infants are seronegative to specific malaria antigens (1, 254), but the kinetics of decay of maternal antibodies show interindividual variations which depend on the antigen and the epidemiological setting (119).”
BackgroundOsier, F. H. A., Fegan, G., Polley, S. D., Murungi, L., Verra, F., Tetteh, K. K. A., Lowe, B., Mwangi, T., Bull, P. C., Thomas, A. W., et al. (2008) · Infection and Immunity · doi:10.1128/iai.01585-07 · Cited by 387
“High-throughput assays employing suspension array technology (27) or microarrays (29, 64) now allow for simultaneous analysis of antibodies to multiple antigens using minimal amounts of sera.”
BackgroundRecent Progress in the Development of Diagnostic Tests for Malaria
Krampa, F. D., Aniweh, Y., Awandare, G. A., & Kanyong, P. (2017) · Diagnostics · doi:10.3390/diagnostics7030054 · Cited by 85
“An attempt to ease the laborious burden of screening large samples against multiple antigens by enzyme immunoassays (EIA) saw Fouda and colleagues [68] implement the suspension array technology (SAT), which employs a fluorescent labelled microsphere with diverse optical properties.”
BackgroundTutterrow, Y. L., Avril, M., Singh, K., Long, C. A., LEKE, R. J. I., Sama, G., Salanti, A., Smith, J. D., Leke, R. G. F., & Taylor, D. W. (2012) · Infection and Immunity · doi:10.1128/iai.00071-12 · Cited by 75
“formed at pH 7 overnight at 4°C as previously described (22), followed by”
MethodSelf-citationHigh Avidity Antibodies to Full-Length VAR2CSA Correlate with Absence of Placental Malaria
Tutterrow, Y. L., Salanti, A., Avril, M., Smith, J. D., Pagano, I., Ako, S. E., Fogako, J., Leke, R. G. F., & Taylor, D. W. (2012) · PLoS ONE · doi:10.1371/journal.pone.0040049 · Cited by 75
“) at pH 7 [40].”
Self-citation
Metadata
- Authors
- Fouda, G. G., Leke, R. F. G., Long, C., Druilhe, P., Zhou, A., Taylor, D. W., & Johnson, A. H.
- Affiliations
- Georgetown University (US)
- Université de Yaoundé I (CM)
- National Institutes of Health (US)
- Institut Pasteur (FR)
- AZ DataClinic, Inc., Rockville, Maryland 20850
- Corresponding author
- Taylor, Diane Wallace
- Venue
- Clinical and Vaccine Immunology
- Publisher
- American Society for Microbiology
- Published
- 2006-12
- Volume
- 13
- Issue
- 12
- Pages
- 1307-1313
- ISSN
- 1556-679X (ISSN-L)
- 1556-6811
- PMC
- PMC1694450
- OpenAlex
- W2091354877
- Cited by
- 80
- References
- 17
- Citations by year
- 2025: 1 · 2023: 4 · 2022: 4 · 2021: 5 · 2020: 9 · 2019: 1 · 2018: 7 · 2017: 8 · 2016: 6 · 2015: 6 · 2014: 3 · 2013: 4 · 2012: 6
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Licence
- journals.asm.org/non-commercial-tdm-license (tdm)
- Locations
- Clinical and Vaccine Immunology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Public Health Agency
- National Institute of Allergy and Infectious Diseases (R21AI053798, U01 AI43888, U01AI043888, R21AI53798)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Malaria Research and Control
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced Biosensing Techniques and Applications
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Drug Discovery › Phytochemical compounds biological activities
- Keywords
- Plasmodium falciparum, malaria antibodies, multiplex immunoassay, merozoite surface protein 1, MSP3, circumsporozoite protein, antibody measurement, microsphere immunoassay, ELISA comparison, finger prick blood, neonatal immune response
- MeSH terms
- Adult, Amino Acid Sequence, Animals, Antibodies, Protozoan, Antigens, Protozoan, Enzyme-Linked Immunosorbent Assay, Humans, Microspheres, Molecular Sequence Data, Plasmodium falciparum, Recombinant Proteins, Sensitivity and Specificity, Reproducibility of Results, Protozoan Proteins, Malaria, Falciparum, Malaria Vaccines
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiplex Assay for Simultaneous Measurement of Antibodies to Multiple Plasmodium falciparum Antigens. https://app.cochat.ai/papers/10.1128/cvi.00183-06
- The paper
- Fouda, G. G., Leke, R. F. G., Long, C., Druilhe, P., Zhou, A., Taylor, D. W., & Johnson, A. H. (2006). Multiplex Assay for Simultaneous Measurement of Antibodies to Multiple Plasmodium falciparum Antigens. Clinical and Vaccine Immunology. https://doi.org/10.1128/cvi.00183-06
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.