Evaluation of a New Etest Vancomycin-Teicoplanin Strip for Detection of Glycopeptide-Intermediate Staphylococcus aureus (GISA), in Particular, Heterogeneous GISA
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Glycopeptide-intermediate Staphylococcus aureus (GISA) and, in particular, heterogeneous GISA (hGISA) are difficult to detect by standard MIC methods, and thus, an accurate detection method for clinical practice and surveillances is needed. Two prototype Etest strips designed for hGISA/GISA resistance detection (GRD) were evaluated using a worldwide collection of hGISA/GISA strains covering the five major clonal lineages. A total of 150 strains comprising 15 GISA and 60 hGISA strains (defined by population analysis profiles-area under the curve [PAP-AUC]), 70 glycopeptide-susceptible S. aureus (GSSA) strains, and 5 S. aureus ATCC reference strains were tested. For standardized Etest vancomycin (VA) MIC testing, the modified Etest macromethod with VA and teicoplanin (TP) strips tested with a heavier inoculum using brain heart infusion agar (BHI) and two glycopeptide screening agar plates (6 μg/ml VA/BHI and 5 μg/ml Mueller-Hinton agar [MHA]) were tested in parallel with the two new Etest GRD strips: a VA 32 (0.5-μg/ml)-TP 32 (0.5-μg/ml) double-sided gradient (E-VA/TP) with one prototype overlaid with a nutrient (E-VA/TP+S) to enhance the growth of hGISA. The Etest GRD strips were tested with a standard 0.5-McFarland standard inoculum using MHA and MHA plus 5% blood (MHB) and were read at 18 to 24 and 48 h. The interpretive MIC cutoffs used for the new Etest GRD strips at 24 and 48 h were as follows: for GISA, TP or VA, ≥8, and a standard VA MIC of ≥6; for hGISA, TP or VA, ≥8, and a standard VA MIC of ≤4. The results on MHB at 48 h showed that E-VA/TP+S had high specificity (94%) and sensitivity (95%) in comparison to PAP-AUC and was able to detect all GISA ( n = 15) and 98% of hGISA ( n = 60) strains. In contrast, the glycopeptide screening plates performed poorly for hGISA. The new Etest GRD strip (E-VA/TP+S), utilizing standard media and inocula, is a simple and acceptable tool for detection of hGISA/GISA for clinical and epidemiologic purposes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Methicillin-resistant Staphylococcus aureus clinical strain with reduced vancomycin susceptibility
Hiramatsu, K. (1997) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/40.1.135 · Cited by 1,984 · cited 1×
“As disk diffusion testing was quickly recognized to be unsuitable (16), other methods have been proposed, such as glycopeptide screening plates (6) and various population studies (11, 29).”
MethodWootton, M. (2001) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/47.4.399 · Cited by 414 · cited 1×
“As disk diffusion testing was quickly recognized to be unsuitable (16), other methods have been proposed, such as glycopeptide screening plates (6) and various population studies (11, 29).”
MethodSelf-citationFridkin, S. K., Hageman, J., McDougal, L. K., Mohammed, J., Jarvis, W. R., Perl, T. M., Tenover, F. C., & the Vancomycin‐Intermediate Staphylococcus aureus Epidemiology Study Group (2003) · Clinical Infectious Diseases · doi:10.1086/346207 · Cited by 344 · cited 1×
“This type of heterogeneous and variable resistance in staphylococci, which is expressed at various frequencies within the population, is not detectable by either disk diffusion (16, 27) or automated susceptibility testing systems (8, 24), a phenomenon recognized by TABLE 2.”
Background
Cited by
Liu, C., Bayer, A., Cosgrove, S. E., Daum, R. S., Fridkin, S. K., Gorwitz, R. J., Kaplan, S. L., Karchmer, A. W., Levine, D. P., Murray, B. E., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/ciq146 · Cited by 4,191
Howden, B. P., Davies, J. K., Johnson, P. D. R., Stinear, T. P., & Grayson, M. L. (2010) · Clinical Microbiology Reviews · doi:10.1128/cmr.00042-09 · Cited by 962
Antimicrobial Susceptibility Testing: A Comprehensive Review of Currently Used Methods
Gajic, I., Kabic, J., Kekic, D., Jovicevic, M., Milenkovic, M., Mitic Culafic, D., Trudic, A., Ranin, L., & Opavski, N. (2022) · Antibiotics · doi:10.3390/antibiotics11040427 · Cited by 557
Antimicrobial heteroresistance: An emerging field in need of clarity
El-Halfawy, O. M., & Valvano, M. A. (2015) · Clinical Microbiology Reviews · doi:10.1128/cmr.00058-14 · Cited by 489
“The lack of standard test formats and global guidelines for determining heteroresistance contributes to disagreements between outcomes of different methods and diverse results from different laboratories (69, 74, 75).”
ResultHuang, Y., Zhang, Y., Yang, S., Lu, H., Yu, H., Wang, X., Jia, X., Tang, D., Wu, L., Huang, S., et al. (2024) · Microbiology Spectrum · doi:10.1128/spectrum.00725-24 · Cited by 12
“Overall, there is a lack of standardized definitions for heteroresistance, as well as standard assays and global guidelines for determining heteroresistance (16, 17), leading to discrepancies in the results obtained from various methods and between different laboratories (28–30).”
Result
Metadata
- Authors
- Yusof, A., Engelhardt, A., Karlsson, A., Bylund, L., Vidh, P., Mills, K., Wootton, M., & Walsh, T. R.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2008-09
- Volume
- 46
- Issue
- 9
- Pages
- 3042-3047
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2124256044
- Cited by
- 97
- References
- 3
- FWCI
- 7.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of a New Etest Vancomycin-Teicoplanin Strip for Detection of Glycopeptide-Intermediate Staphylococcus aureus (GISA), in Particular, Heterogeneous GISA. https://app.cochat.ai/papers/10.1128/jcm.00265-08
- The paper
- Yusof, A., Engelhardt, A., Karlsson, A., Bylund, L., Vidh, P., Mills, K., Wootton, M., & Walsh, T. R. (2008). Evaluation of a New Etest Vancomycin-Teicoplanin Strip for Detection of Glycopeptide-Intermediate Staphylococcus aureus (GISA), in Particular, Heterogeneous GISA. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.00265-08
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.