CoChat

Diagnostic Value of Galactomannan Antigen Test in Serum and Bronchoalveolar Lavage Fluid Samples from Patients with Nonneutropenic Invasive Pulmonary Aspergillosis

Open access
Zhou, Wei, Li, Hongxing, Zhang, Yan, Huang, Mei, He, Qian, Li, Pei, Zhang, Fang, Shi, Yi, Su, Xin · 2017 · Journal of Clinical Microbiology
Cited by 206

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Abstract

The objective of this study was to compare the diagnostic value of galactomannan (GM) detection in bronchoalveolar lavage fluid (BALF) and serum samples from nonneutropenic patients with invasive pulmonary aspergillosis (IPA) and determine the optimal BALF GM cutoff value for pulmonary aspergillosis. GM detection in BALF and serum samples was performed by enzyme-linked immunosorbent assay (ELISA) in 128 patients with clinically suspected nonneutropenic pulmonary aspergillosis between June 2014 and June 2016. On the basis of the clinical and pathological diagnoses, 8 patients were excluded because their diagnosis was uncertain. The remaining 120 patients were diagnosed with either IPA ( n = 37), community-acquired pneumonia (CAP; n = 59), noninfectious diseases ( n = 19), or tuberculosis ( n = 5). At a cutoff optical density index (ODI) value of ≥0.5, the sensitivity of BALF GM detection was much higher than that of serum GM detection (75.68% versus 37.84%; P = 0.001), but there was no significant difference between their specificities (80.72% versus 87.14%; P = 0.286). At a cutoff value of ≥1.0, the sensitivity of BALF GM detection was still much higher than that of serum GM detection (64.86% versus 24.32%; P < 0.001), and their specificities were similar (90.36% versus 95.71%; P = 0.202). Receiver operating characteristic (ROC) curve analysis showed that when the BALF GM detection cutoff value was 0.7, its diagnostic value for pulmonary aspergillosis was optimized, and the sensitivity and specificity reached 72.97% and 89.16%, respectively. BALF GM detection was valuable for the diagnosis of IPA in nonneutropenic patients, and its diagnostic value was superior to that of serum GM detection. The optimal BALF GM cutoff value was 0.7.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.00345-17

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

Metadata

Authors
Zhou, W., Li, H., Zhang, Y., Huang, M., He, Q., Li, P., Zhang, F., Shi, Y., & Su, X.
Venue
Journal of Clinical Microbiology
Published
2017-07
Volume
55
Issue
7
Pages
2153-2161
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2609820370
Cited by
206
References
22
FWCI
11.19
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.