Multicenter Comparison of Different Real-Time PCR Assays for Quantitative Detection of Epstein-Barr Virus
Open accessThe DOI matches its Crossref record.
Abstract
Quantification of Epstein-Barr virus (EBV) in peripheral blood is important for the diagnosis and management of serious EBV diseases, including posttransplant lymphoproliferative disorder. A variety of PCR-based methods are currently in use; however, there is little information on their comparability. This study assessed the relative performance of different quantitative assays. A multicenter comparative study was performed at eight sites using three panels consisting of serial dilutions of quantified EBV DNA and extracts from a total of 19 whole-blood specimens. Samples were distributed and tested blindly. Instrumentation, probe chemistries, amplification targets, and other test-related aspects varied considerably between laboratories. Each laboratory's calibration curve indicated strong evidence of a consistent log-linear relationship between viral load and cycle threshold, suggesting that intralaboratory tracking of a given patient would yield similar relative quantitative trends among the participating test sites. There was strong concordance among laboratories with respect to qualitative test results; however, marked quantitative discordance was seen. For most samples, the across-laboratory interquartile range of the reported viral load (in copies/μl) was roughly 0.6 log-units, and for one sample the overall range was approximately 4.2 log-units. While intralaboratory tracking of patients may yield similar results, these data indicate a need for caution when attempting to compare clinical results obtained at different institutions and suggest the potential value to be gained by more standardized testing methodology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Ultimate qPCR Experiment: Producing Publication Quality, Reproducible Data the First Time
Taylor, S. C., Nadeau, K., Abbasi, M., Lachance, C., Nguyen, M., & Fenrich, J. (2019) · Trends in Biotechnology · doi:10.1016/j.tibtech.2018.12.002 · Cited by 830
Quan, P.-L., Sauzade, M., & Brouzes, E. (2018) · Sensors · doi:10.3390/s18041271 · Cited by 664
Progress and Problems in Understanding and Managing Primary Epstein-Barr Virus Infections
Odumade, O. A., Hogquist, K. A., & Balfour, H. H. (2011) · Clinical Microbiology Reviews · doi:10.1128/cmr.00044-10 · Cited by 458
Self-citationWhy the need for qPCR publication guidelines?—The case for MIQE
Bustin, S. A. (2010) · Methods · doi:10.1016/j.ymeth.2009.12.006 · Cited by 375
Allen, U. D., Preiksaitis, J. K., & Practice, T. A. I. D. C. O. (2019) · Clinical Transplantation · doi:10.1111/ctr.13652 · Cited by 375
Comparison of Droplet Digital PCR to Real-Time PCR for Quantitative Detection of Cytomegalovirus
Hayden, R. T., Gu, Z., Ingersoll, J., Abdul-Ali, D., Shi, L., Pounds, S., & Caliendo, A. M. (2013) · Journal of Clinical Microbiology · doi:10.1128/jcm.02620-12 · Cited by 335
Self-citationSerological diagnosis of Epstein-Barr virus infection: Problems and solutions
De Paschale, M. (2012) · World Journal of Virology · doi:10.5501/wjv.v1.i1.31 · Cited by 333
Laboratory Assays for Epstein-Barr Virus-Related Disease
Gulley, M. L., & Tang, W. (2008) · The Journal of Molecular Diagnostics · doi:10.2353/jmoldx.2008.080023 · Cited by 324
Smatti, M. K., Al-Sadeq, D. W., Ali, N. H., Pintus, G., Abou-Saleh, H., & Nasrallah, G. K. (2018) · Frontiers in Oncology · doi:10.3389/fonc.2018.00211 · Cited by 309
Post-transplant lymphoproliferative disorders
Dharnidharka, V. R., Webster, A. C., Martinez, O. M., Preiksaitis, J. K., Leblond, V., & Choquet, S. (2016) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2015.88 · Cited by 235
Allen, U., & Preiksaitis, J. (2009) · American Journal of Transplantation · doi:10.1111/j.1600-6143.2009.02898.x · Cited by 214
“However, significant and extreme interlaboratory variability exists in both qualitative and quantitative viral load results, raising questions regarding the validity of interinstitutional result comparison in the absence of formal cross-referencing of assays between institutions (25,26).”
BackgroundMethodHayden, R. T., Yan, X., Wick, M. T., Rodriguez, A. B., Xiong, X., Ginocchio, C. C., Mitchell, M. J., & Caliendo, A. M. (2012) · Journal of Clinical Microbiology · doi:10.1128/jcm.01287-11 · Cited by 159
“While a limited number of studies have addressed this issue, most have focused solely on lack of standardized quantitative calibrators as a primary reason for differences in precision and accuracy among laboratories (2, 6, 18).”
BackgroundSelf-citationTaylor, S. C., Carbonneau, J., Shelton, D. N., & Boivin, G. (2015) · Journal of Virological Methods · doi:10.1016/j.jviromet.2015.08.014 · Cited by 142
Hanson, K. E., Slechta, E. S., Killpack, J. A., Heyrend, C., Lunt, T., Daly, J. A., Hemmert, A. C., & Blaschke, A. J. (2016) · Journal of Clinical Microbiology · doi:10.1128/jcm.02850-15 · Cited by 86
Metadata
- Authors
- Hayden, R. T., Hokanson, K. M., Pounds, S. B., Bankowski, M. J., Belzer, S. W., Carr, J., Diorio, D., Forman, M. S., Joshi, Y., Hillyard, D., Hodinka, R. L., Nikiforova, M. N., Romain, C. A., Stevenson, J., Valsamakis, A., & Balfour, H. H.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2008-01
- Volume
- 46
- Issue
- 1
- Pages
- 157-163
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2100348181
- Cited by
- 138
- References
- 0
- FWCI
- 2.87
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.