Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 262

The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.

Diagnostic Accuracy of Rapid Antigen Detection Tests for Respiratory Syncytial Virus Infection: Systematic Review and Meta-analysis

Open access
Chartrand, Caroline, Tremblay, Nicolas, Renaud, Christian, Papenburg, Jesse · 2015 · Journal of Clinical Microbiology

Abstract

Respiratory syncytial virus (RSV) rapid antigen detection tests (RADT) are extensively used in clinical laboratories. We performed a systematic review and meta-analysis to evaluate the accuracy of RADTs for diagnosis of RSV infection and to determine factors associated with accuracy estimates. We searched EMBASE and PubMed for diagnostic-accuracy studies of commercialized RSV RADTs. Studies reporting sensitivity and specificity data compared to a reference standard (reverse transcriptase PCR [RT-PCR], immunofluorescence, or viral culture) were considered. Two reviewers independently extracted data on study characteristics, diagnostic-accuracy estimates, and study quality. Accuracy estimates were pooled using bivariate random-effects regression models. Heterogeneity was investigated with prespecified subgroup analyses. Seventy-one articles met inclusion criteria. Overall, RSV RADT pooled sensitivity and specificity were 80% (95% confidence interval [CI], 76% to 83%) and 97% (95% CI, 96% to 98%), respectively. Positive- and negative-likelihood ratios were 25.5 (95% CI, 18.3 to 35.5) and 0.21 (95% CI, 0.18 to 0.24), respectively. Sensitivity was higher in children (81% [95% CI, 78%, 84%]) than in adults (29% [95% CI, 11% to 48%]). Because of this disparity, further subgroup analyses were restricted to pediatric data (63 studies). Test sensitivity was poorest using RT-PCR as a reference standard and highest using immunofluorescence (74% versus 88%; P < 0.001). Industry-sponsored studies reported significantly higher sensitivity (87% versus 78%; P = 0.01). Our results suggest that the poor sensitivity of RSV RADTs in adults may preclude their use in this population. Furthermore, industry-sponsored studies and those that did not use RT-PCR as a reference standard likely overestimated test sensitivity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.01816-15

Cites

50 of 50 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 50 references

Cited by

See all 262

Metadata

Authors
Chartrand, C., Tremblay, N., Renaud, C., & Papenburg, J.
Venue
Journal of Clinical Microbiology
Published
2015-12
Volume
53
Issue
12
Pages
3738-3749
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W1836636493
Cited by
262
References
50
FWCI
2.63
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic Accuracy of Rapid Antigen Detection Tests for Respiratory Syncytial Virus Infection: Systematic Review and Meta-analysis. https://app.cochat.ai/papers/10.1128/jcm.01816-15
The paper
Chartrand, C., Tremblay, N., Renaud, C., & Papenburg, J. (2015). Diagnostic Accuracy of Rapid Antigen Detection Tests for Respiratory Syncytial Virus Infection: Systematic Review and Meta-analysis. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.01816-15

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.