Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 287

The DOI matches its Crossref record; 88 of the 88 references it cites were found in a registry or an index.

Diagnostic Accuracy of Novel and Traditional Rapid Tests for Influenza Infection Compared With Reverse Transcriptase Polymerase Chain Reaction: A Systematic Review and Meta-analysis

Merckx, Joanna, Wali, Rehab, Schiller, Ian, Caya, Chelsea, Gore, Genevieve C., Chartrand, Caroline, Dendukuri, Nandini, Papenburg, Jesse·2017·Annals of Internal Medicine

Abstract

BACKGROUND: Rapid and accurate influenza diagnostics can improve patient care. PURPOSE: To summarize and compare accuracy of traditional rapid influenza diagnostic tests (RIDTs), digital immunoassays (DIAs), and rapid nucleic acid amplification tests (NAATs) in children and adults with suspected influenza. DATA SOURCES: 6 databases from their inception through May 2017. STUDY SELECTION: Studies in English, French, or Spanish comparing commercialized rapid tests (that is, providing results in <30 minutes) with reverse transcriptase polymerase chain reaction reference standard for influenza diagnosis. DATA EXTRACTION: Data were extracted using a standardized form; quality was assessed using QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2) criteria. DATA SYNTHESIS: 162 studies were included (130 of RIDTs, 19 of DIAs, and 13 of NAATs). Pooled sensitivities for detecting influenza A from Bayesian bivariate random-effects models were 54.4% (95% credible interval [CrI], 48.9% to 59.8%) for RIDTs, 80.0% (CrI, 73.4% to 85.6%) for DIAs, and 91.6% (CrI, 84.9% to 95.9%) for NAATs. Those for detecting influenza B were 53.2% (CrI, 41.7% to 64.4%) for RIDTs, 76.8% (CrI, 65.4% to 85.4%) for DIAs, and 95.4% (CrI, 87.3% to 98.7%) for NAATs. Pooled specificities were uniformly high (>98%). Forty-six influenza A and 24 influenza B studies presented pediatric-specific data; 35 influenza A and 16 influenza B studies presented adult-specific data. Pooled sensitivities were higher in children by 12.1 to 31.8 percentage points, except for influenza A by rapid NAATs (2.7 percentage points). Pooled sensitivities favored industry-sponsored studies by 6.2 to 34.0 percentage points. Incomplete reporting frequently led to unclear risk of bias. LIMITATIONS: Underreporting of clinical variables limited exploration of heterogeneity. Few NAAT studies reported adult-specific data, and none evaluated point-of-care testing. Many studies had unclear risk of bias. CONCLUSION: Novel DIAs and rapid NAATs had markedly higher sensitivities for influenza A and B in both children and adults than did traditional RIDTs, with equally high specificities. PRIMARY FUNDING SOURCE: Québec Health Research Fund and BD Diagnostic Systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/m17-0848

Cites

88 of 88 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 88 references

Cited by

See all 287

Metadata

Authors
Merckx, J., Wali, R., Schiller, I., Caya, C., Gore, G. C., Chartrand, C., Dendukuri, N., & Papenburg, J.
Venue
Annals of Internal Medicine
Published
2017-09-19
Volume
167
Issue
6
Pages
394-409
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2752140764
Cited by
287
References
88
FWCI
23.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic Accuracy of Novel and Traditional Rapid Tests for Influenza Infection Compared With Reverse Transcriptase Polymerase Chain Reaction: A Systematic Review and Meta-analysis. https://app.cochat.ai/papers/10.7326/m17-0848
The paper
Merckx, J., Wali, R., Schiller, I., Caya, C., Gore, G. C., Chartrand, C., Dendukuri, N., & Papenburg, J. (2017). Diagnostic Accuracy of Novel and Traditional Rapid Tests for Influenza Infection Compared With Reverse Transcriptase Polymerase Chain Reaction: A Systematic Review and Meta-analysis. Annals of Internal Medicine. https://doi.org/10.7326/m17-0848

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.