CoChat

Rapid Detection of Staphylococcus aureus Panton-Valentine Leukocidin in Clinical Specimens by Enzyme-Linked Immunosorbent Assay and Immunochromatographic Tests

Open access
Badiou, Cedric, Dumitrescu, Oana, George, Narelle, Forbes, Andrea R. N., Drougka, Eleanna, Chan, Kian Sing, Ramdani-Bouguessa, Nadjia, Meugnier, Helene, Bes, Michele, Vandenesch, Francois, Etienne, Jerome, Hsu, Li Yang, Tazir, Mohamed, Spiliopoulou, Iris, Nimmo, Graeme R., Hulten, Kristina G., Lina, Gerard · 2010 · Journal of Clinical Microbiology
Cited by 79

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Staphylococcus aureus strains producing Panton-Valentine leukocidin (PVL) have been epidemiologically linked to specific human infections. To evaluate immunological tests that may be used to diagnose infections with PVL-producing strains, we prospectively collected pus, respiratory tract specimens, and joint fluid specimens from which S. aureus had been isolated in clinical laboratories in six countries. An enzyme-linked immunosorbent assay (ELISA) and an immunochromatographic test (ICT) targeting LukS-PV were performed directly with clinical samples for the detection of PVL. The same tests were applied to S. aureus culture supernatants. The corresponding S. aureus isolates were characterized by PCR for the presence of the PVL locus ( lukS-PV and lukF-PV ) and the mec A gene. A total of 185 samples from 144 skin infections, 23 bone and joint infections, and 18 lower respiratory tract infections were analyzed. By PCR, 72/185 S. aureus isolates were PVL locus positive (PVL + ); 28 of these were also mecA positive. PVL was detected in the supernatants of all PVL + strains by both ELISA and an ICT, while no signal was observed with PVL-negative strains. The PVL concentrations in human clinical samples that grew PVL + strains ranged from 0 to 399 μg/ml by ELISA. By the use of 0.015 μg/ml of PVL as a cutoff value, PVL was detected in 65/72 (90%) of the clinical samples by ELISA. The sensitivity and specificity of the ELISA test were 90% and 100%, respectively. By the ICT, PVL was detected in 57/72 (79%) of the samples, and the sensitivity and specificity of ICT were 79% and 100%, respectively. PVL is expressed by S. aureus during human infection, and a PVL-specific ELISA and ICT could be reliable tests for the diagnosis of infections caused by PVL-producing strains.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.02274-09

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 79

Metadata

Authors
Badiou, C., Dumitrescu, O., George, N., Forbes, A. R. N., Drougka, E., Chan, K. S., Ramdani-Bouguessa, N., Meugnier, H., Bes, M., Vandenesch, F., Etienne, J., Hsu, L. Y., Tazir, M., Spiliopoulou, I., Nimmo, G. R., Hulten, K. G., & Lina, G.
Venue
Journal of Clinical Microbiology
Published
2010-04
Volume
48
Issue
4
Pages
1384-1390
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2090578181
Cited by
79
References
5
FWCI
5.38
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.