Automated versus Manual Sample Inoculations in Routine Clinical Microbiology: a Performance Evaluation of the Fully Automated InoqulA Instrument
Open accessThe DOI matches its Crossref record.
Abstract
The process of plate streaking has been automated to improve the culture readings, isolation quality, and workflow of microbiology laboratories. However, instruments have not been well evaluated under routine conditions. We aimed to evaluate the performance of the fully automated InoqulA instrument (BD Kiestra B.V., The Netherlands) in the automated seeding of liquid specimens and samples collected using swabs with transport medium. We compared manual and automated methods according to the (i) within-run reproducibility using Escherichia coli -calibrated suspensions, (ii) intersample contamination using a series of alternating sterile broths and broths with >10 5 CFU/ml of either E. coli or Proteus mirabilis , (iii) isolation quality with standardized mixed bacterial suspensions of diverse complexity and a 4-category standardized scale (very poor, poor, fair to good, or excellent), and (iv) agreement of the results obtained from 244 clinical specimens. By involving 15 technicians in the latter part of the comparative study, we estimated the variability in the culture quality at the level of the laboratory team. The instrument produced satisfactory reproducibility with no sample cross-contamination, and it performed better than the manual method, with more colony types recovered and isolated (up to 11% and 17%, respectively). Finally, we showed that the instrument did not shorten the seeding time over short periods of work compared to that for the manual method. Altogether, the instrument improved the quality and standardization of the isolation, thereby contributing to a better overall workflow, shortened the time to results, and provided more accurate results for polymicrobial specimens.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Automation and artificial intelligence in the clinical laboratory
Naugler, C., & Church, D. L. (2019) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2018.1561640 · Cited by 112
Faron, M. L., Buchan, B. W., Relich, R. F., Clark, J., & Ledeboer, N. A. (2020) · Journal of Clinical Microbiology · doi:10.1128/jcm.01683-19 · Cited by 41
“Studies evaluating automated processing instruments found improved isolation and recovery of bacterial colonies, which allowed identification (ID) and antimicrobial susceptibility testing (AST) to be performed more often from primary plates than manual processing (7, 8).”
MethodGraham, M., Tilson, L., Streitberg, R., Hamblin, J., & Korman, T. M. (2016) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2016.06.020 · Cited by 40
Trigueiro, G., Oliveira, C., Rodrigues, A., Seabra, S., Pinto, R., Bala, Y., Gutiérrez Granado, M., Vallejo, S., Gonzalez, V., & Cardoso, C. (2024) · Microbiology Spectrum · doi:10.1128/spectrum.02153-23 · Cited by 17
Metadata
- Authors
- Froment, P., Marchandin, H., Vande Perre, P., & Lamy, B.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2014-03
- Volume
- 52
- Issue
- 3
- Pages
- 796-802
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2138528895
- Cited by
- 45
- References
- 0
- FWCI
- 2.05
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.