Development of a Respiratory Virus Panel Test for Detection of Twenty Human Respiratory Viruses by Use of Multiplex PCR and a Fluid Microbead-Based Assay

Open access
Mahony, J., Chong, S., Merante, F., Yaghoubian, S., Sinha, T., Lisle, C., Janeczko, R.·2007·Journal of Clinical Microbiology

Abstract

Virology laboratories historically have used direct fluorescent-antibody assay (DFA) and culture to detect six or seven respiratory viruses. Following the discovery of five new human respiratory viruses since 2000, there is an increasing need for diagnostic tests to detect these emerging viruses. We have developed a new test that can detect 20 different respiratory virus types/subtypes in a single 5-h test. The assay employs multiplex PCR using 14 virus-specific primer pairs, followed by a multiplexed target-specific primer extension (TSPE) reaction using 21 primers for specific respiratory virus types and subtypes. TSPE products were sorted and identified by using a fluid microsphere-based array (Universal Array; TmBioscience Corporation, Toronto, Canada) and the Luminex x-MAP system. The assay detected influenza A and B viruses; influenza A virus subtypes H1, H3, and H5 (including subtype H5N1 of the Asian lineage); parainfluenza virus types 1, 2, 3, and 4; respiratory syncytial virus types A and B; adenovirus; metapneumovirus; rhinovirus; enterovirus; and coronaviruses OC43, 229E, severe acute respiratory syndrome coronavirus, NL63, and HKU1. In a prospective evaluation using 294 nasopharyngeal swab specimens, DFA/culture detected 119 positives and the respiratory virus panel (RVP) test detected 112 positives, for a sensitivity of 97%. The RVP test detected an additional 61 positive specimens that either were not detected by DFA/culture or were positive for viruses not tested for by DFA/culture. After resolution of discordant results by using a second unique PCR assay and by using a combined reference standard of positivity, the RVP test detected 180 of 183 true positives, for a sensitivity of 98.5%, whereas DFA and culture detected only 126 of 183 true positives, for a sensitivity of 68.8%. The RVP test should improve the capabilities of hospital and public health laboratories for diagnosing viral respiratory tract infections and should assist public health agencies in identifying etiologic agents in respiratory tract infection outbreaks.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.02436-06

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 360

Metadata

Authors
Mahony, J., Chong, S., Merante, F., Yaghoubian, S., Sinha, T., Lisle, C., & Janeczko, R.
Venue
Journal of Clinical Microbiology
Published
2007-09
Volume
45
Issue
9
Pages
2965-2970
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2151916354
Cited by
360
References
7
FWCI
24.50
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development of a Respiratory Virus Panel Test for Detection of Twenty Human Respiratory Viruses by Use of Multiplex PCR and a Fluid Microbead-Based Assay. https://app.cochat.ai/papers/10.1128/jcm.02436-06
The paper
Mahony, J., Chong, S., Merante, F., Yaghoubian, S., Sinha, T., Lisle, C., & Janeczko, R. (2007). Development of a Respiratory Virus Panel Test for Detection of Twenty Human Respiratory Viruses by Use of Multiplex PCR and a Fluid Microbead-Based Assay. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.02436-06

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.