Cited by 17Tuberculosis Research and EpidemiologyInfectious Diseases and TuberculosisMycobacterium research and diagnosis

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Detection of Mycobacterium tuberculosis by EasyNAT Diagnostic Kit in Sputum Samples from Tanzania

Open access

Abstract

The EasyNAT assay was evaluated for the detection of tuberculosis in sputum smears from presumptive pulmonary tuberculosis (TB) patients in an African high-TB and high-HIV setting. The sensitivity of the EasyNAT assay was 66.7%, and the specificity and positive predictive value were 100% for the culture-positive patients. The sensitivity was only 10% in the smear-negative and culture-positive patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.03037-14

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The suboptimal limit of detection of EasyNAT probably explains its poor sensitivity in this paediatric study, where low density of mycobacteria is expected in lymph nodes.

    “Sensitivity in these studies was further reduced when only smear-negative but culture-positive pulmonary TB cases were tested (59.8 and 10 %) which indicates a suboptimal limit of detection that probably could explain the poor sensitivity with our paediatric patients, where low density of mycobacteria is expected in lymph nodes.”

    From Evaluation of Xpert® MTB/RIF and Ustar EasyNAT™ TB IAD for diagnosis of tuberculous lymphadenitis of children in Tanzania: a prospective descriptive study (2016) · cites this paper as [41]

    The passage labeled Abstract reports 10% EasyNAT sensitivity in smear-negative, culture-positive sputum samples and attributes the low detection rate to bacillary DNA below the assay’s detection limit. The paper does not study paediatric patients or lymph-node samples, so it does not establish that this mechanism explains the citing study’s poor sensitivity. (LLM, conf=0.86)

    Experimental — accuracy not yet measured
  • Until now, EasyNAT has only been evaluated for the detection of pulmonary TB in adults.

    “Until now, EasyNAT, a manual assay based on isothermal cross-priming amplification, has only been evaluated for the detection of pulmonary TB in adults [40, 41].”

    From Evaluation of Xpert® MTB/RIF and Ustar EasyNAT™ TB IAD for diagnosis of tuberculous lymphadenitis of children in Tanzania: a prospective descriptive study (2016) · cites this paper as [41]

    The study description (section labeled Abstract; page unavailable) evaluates EasyNAT using sputum from presumptive pulmonary TB patients, and the reported mean age is 40.5 years. The copy does not establish that all participants were adults or that EasyNAT had only been evaluated in adults for pulmonary TB. (LLM, conf=0.78)

    Experimental — accuracy not yet measured
  • Two studies reported sensitivity for M. tuberculosis detection against culture of 84.1% and 66.7%, and specificity of 97.8% and 100%, for EasyNAT.

    “These two studies reported sensitivity for M. tuberculosis detection against culture of 84.1 and 66.7 %, and specificity of 97.8 and 100 %.”
  • Sensitivity in prior EasyNAT studies was further reduced when only smear-negative but culture-positive pulmonary TB cases were tested (59.8% and 10%), indicating a suboptimal limit of detection.

    “Sensitivity in these studies was further reduced when only smear-negative but culture-positive pulmonary TB cases were tested (59.8 and 10 %) which indicates a suboptimal limit of detection that probably could explain the poor sensitivity with our paediatric patients, where low density of mycobacteria is expected in lymph nodes.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Metadata

Authors
Mhimbira, F. A., Bholla, M., Sasamalo, M., Mukurasi, W., Hella, J. J., Jugheli, L., & Reither, K.
Affiliations
Ifakara Health Institute (TZ)
Venue
Journal of Clinical Microbiology
Published
2015-04
Volume
53
Issue
4
Pages
1342-1344
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W1975783957
Cited by
17
References
12
Citations by year
2026: 1 · 2023: 3 · 2022: 1 · 2020: 1 · 2019: 1 · 2018: 4 · 2017: 2 · 2016: 2 · 2015: 2
FWCI
2.60
Type
journal article
Language
en
Open access
Locations
  • Journal of Clinical Microbiology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Utah Science Technology and Research
  • Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (131192)
  • European and Developing Countries Clinical Trials Partnership
Topics
  • Health Sciences › Medicine › Infectious Diseases › Tuberculosis Research and Epidemiology
  • Health Sciences › Medicine › Infectious Diseases › Infectious Diseases and Tuberculosis
  • Health Sciences › Medicine › Epidemiology › Mycobacterium research and diagnosis
Keywords
Mycobacterium tuberculosis, nucleic acid amplification tests, tuberculosis diagnosis, sputum smear microscopy, pulmonary tuberculosis, HIV coinfection, diagnostic sensitivity, culture-positive tuberculosis, Tanzania
MeSH terms
Bacteriological Techniques, Humans, Mycobacterium tuberculosis, Predictive Value of Tests, Reagent Kits, Diagnostic, Sensitivity and Specificity, Sputum, Tanzania, Tuberculosis, Pulmonary

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›