Clinical evaluation of the lysis-centrifugation blood culture system for the detection of fungemia and comparison with a conventional biphasic broth blood culture system
Open accessThe DOI matches its Crossref record.
Abstract
In a comparative fungal blood culture study, a lysis-centrifugation system (Isolator; Du Pont Co., Wilmington, Del.) detected 89% of all episodes of fungemia; the lysis-centrifugation system detected fungemia exclusively or significantly earlier than did a biphasic brain heart infusion bottle system 83% of the time. The lysis-centrifugation system was particularly useful in the early detection of fungemia caused by Candida tropicalis and Candida glabrata. In 53% of the clinically significant episodes, the earlier detection was directly helpful in the management of patients with fungemia. High-magnitude candidemia (greater than 5 CFU/ml of blood) was significantly associated with the presence of an infected intravascular catheter and with Candida species other than Candida albicans. The lysis-centrifugation system was sensitive in the detection of fungemia during the monitoring of patients receiving antifungal agents or after removal of an infected intravascular catheter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Update on detection of bacteremia and fungemia
Reimer, L. G., Wilson, M. L., & Weinstein, M. P. (1997) · Clinical Microbiology Reviews · doi:10.1128/cmr.10.3.444 · Cited by 482
Lamy, B., Dargère, S., Arendrup, M. C., Parienti, J.-J., & Tattevin, P. (2016) · Frontiers in Microbiology · doi:10.3389/fmicb.2016.00697 · Cited by 447
Berenguer, J., Buck, M., Witebsky, F., Stock, F., Pizzo, P. A., & Walsh, T. J. (1993) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/0732-8893(93)90020-8 · Cited by 290
Quantitation of Candida CFU in Initial Positive Blood Cultures
Pfeiffer, C. D., Samsa, G. P., Schell, W. A., Reller, L. B., Perfect, J. R., & Alexander, B. D. (2011) · Journal of Clinical Microbiology · doi:10.1128/jcm.00609-11 · Cited by 158
Time to blood culture positivity as a marker for catheter-related candidemia
Ben-Ami, R., Weinberger, M., Orni-Wasserlauff, R., Schwartz, D., Itzhaki, A., Lazarovitch, T., Bash, E., Aharoni, Y., Moroz, I., & Giladi, M. (2008) · Journal of Clinical Microbiology · doi:10.1128/jcm.00214-08 · Cited by 90
“High-grade candidemia ( 5 CFU/ml) detected in peripheral blood has previously been shown to correlate with the presence of an infected intravascular catheter (1).”
Background
Metadata
- Authors
- Bille, J., Edson, R. S., & Roberts, G. D.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1984-02
- Volume
- 19
- Issue
- 2
- Pages
- 126-128
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W1783713200
- Cited by
- 93
- References
- 0
- FWCI
- 4.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical evaluation of the lysis-centrifugation blood culture system for the detection of fungemia and comparison with a conventional biphasic broth blood culture system. https://app.cochat.ai/papers/10.1128/jcm.19.2.126-128.1984
- The paper
- Bille, J., Edson, R. S., & Roberts, G. D. (1984). Clinical evaluation of the lysis-centrifugation blood culture system for the detection of fungemia and comparison with a conventional biphasic broth blood culture system. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.19.2.126-128.1984
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.