Adherence of coagulase-negative staphylococci to plastic tissue culture plates: a quantitative model for the adherence of staphylococci to medical devices
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
The adherence of coagulase-negative staphylococci to smooth surfaces was assayed by measuring the optical densities of stained bacterial films adherent to the floors of plastic tissue culture plates. The optical densities correlated with the weight of the adherent bacterial film (r = 0.906; P less than 0.01). The measurements also agreed with visual assessments of bacterial adherence to culture tubes, microtiter plates, and tissue culture plates. Selected clinical strains were passed through a mouse model for foreign body infections and a rat model for catheter-induced endocarditis. The adherence measurements of animal passed strains remained the same as those of the laboratory-maintained parent strain. Spectrophotometric classification of coagulase-negative staphylococci into nonadherent and adherent categories according to these measurements had a sensitivity, specificity, and accuracy of 90.6, 80.8, and 88.4%, respectively. We examined a previously described collection of 127 strains of coagulase-negative staphylococci isolated from an outbreak of intravascular catheter-associated sepsis; strains associated with sepsis were more adherent than blood culture contaminants and cutaneous strains (P less than 0.001). We also examined a collection of 84 strains isolated from pediatric patients with cerebrospinal fluid (CSF) shunts; once again, pathogenic strains were more adherent than were CSF contaminants (P less than 0.01). Finally, we measured the adherence of seven endocarditis strains. As opposed to strains associated with intravascular catheters and CSF shunts, endocarditis strains were less adherent than were saprophytic strains of coagulase-negative staphylococci. The optical densities of bacterial films adherent to plastic tissue culture plates serve as a quantitative model for the study of the adherence of coagulase-negative staphylococci to medical devices, a process which may be important in the pathogenesis of foreign body infections.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Histochemistry: Theoretical and Applied
(1953) · Journal of the American Medical Association · doi:10.1001/jama.1953.02940280072039 · Cited by 7,021
A Semiquantitative Culture Method for Identifying Intravenous-Catheter-Related Infection
Maki, D. G., Weise, C. E., & Sarafin, H. W. (1977) · New England Journal of Medicine · doi:10.1056/nejm197706092962301 · Cited by 2,027
Adherence of slime-producing strains of Staphylococcus epidermidis to smooth surfaces
Christensen, G. D., Simpson, W. A., Bisno, A. L., & Beachey, E. H. (1982) · Infection and Immunity · doi:10.1128/iai.37.1.318-326.1982 · Cited by 1,410
Self-citationAdherence and Growth of Coagulase-Negative Staphylococci on Surfaces of Intravenous Catheters
Peters, G., Locci, R., & Pulverer, G. (1982) · Journal of Infectious Diseases · doi:10.1093/infdis/146.4.479 · Cited by 559
Fletcher, M. (1977) · Canadian Journal of Microbiology · doi:10.1139/m77-001 · Cited by 395
Marrie, T. J., & Costerton, J. W. (1984) · Journal of Clinical Microbiology · doi:10.1128/jcm.19.5.687-693.1984 · Cited by 327 · cited 1×
“In recent years, several groups of investigators have conducted scanning electron microscope surveys of naturally infected intravascular catheters (11, 21, 26), peritoneal dialysis catheters (23), and pacemaker leads (22, 28) and found adherent deposits of coagulase-negative staphylococci.”
BackgroundNosocomial Septicemia Due to Multiply Antibiotic-Resistant Staphylococcus epidermidis
CHRISTENSEN, G. D., BISNO, A. L., PARISI, J. T., McLAUGHLIN, B., HESTER, M. G., & LUTHER, R. W. (1982) · Annals of Internal Medicine · doi:10.7326/0003-4819-96-1-1 · Cited by 308
Self-citationNatural Populations of the Genus Staphylococcus
Kloos, W. E. (1980) · Annual Review of Microbiology · doi:10.1146/annurev.mi.34.100180.003015 · Cited by 297
Staphylococcus epidermidis Infections
Lowy, F. D., & HAMMER, S. M. (1983) · Annals of Internal Medicine · doi:10.7326/0003-4819-99-6-834 · Cited by 212
Adhesion of Coagulase-negative Staphylococci to Biomaterials
Hogt, A. H., Dankert, J., De Vries, J. A., & Feijen, J. (1983) · Microbiology · doi:10.1099/00221287-129-9-2959 · Cited by 188
The Effects of Proteins on Bacterial Attachment to Polystyrene
Fletcher, M. (1976) · Journal of General Microbiology · doi:10.1099/00221287-94-2-400 · Cited by 187
Peters, G., Locci, R., & Pulverer, G. (1981) · PubMed · Cited by 180
PENNY, R. B. S. R. (1972) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.1972.tb09769.x · Cited by 175
Marrie, T. J., Noble, M. A., & Costerton, J. W. (1983) · Journal of Clinical Microbiology · doi:10.1128/jcm.18.6.1388-1398.1983 · Cited by 138
Scanning electron microscopy of bacteria adherent to intravascular catheters
Franson, T. R., Sheth, N. K., Rose, H. D., & Sohnle, P. G. (1984) · Journal of Clinical Microbiology · doi:10.1128/jcm.20.3.500-505.1984 · Cited by 131
Attachment of staphylococci to various synthetic polymers
Ludwicka, A., Jansen, B., Wadström, T., & Pulverer, G. (1984) · Zentralblatt für Bakteriologie Mikrobiologie und Hygiene 1 Abt Originale A Medizinische Mikrobiologie Infektionskrankheiten und Parasitologie · doi:10.1016/s0174-3031(84)80024-4 · Cited by 110
Staat, R. H., Langley, S. D., & Doyle, R. J. (1980) · Infection and Immunity · doi:10.1128/iai.27.2.675-681.1980 · Cited by 100
Investigations on staphylococcal infection of transvenous endocardial pacemaker electrodes
Peters, G., Saborowski, F., Locci, R., & Pulverer, G. (1984) · American Heart Journal · doi:10.1016/0002-8703(84)90625-2 · Cited by 72
Morphology of bacterial attachment to cardiac pacemaker leads and power packs
Marrie, T. J., & Costerton, J. W. (1984) · Journal of Clinical Microbiology · doi:10.1128/jcm.19.6.911-914.1984 · Cited by 65
Locci, R., Peters, G., & Pulverer, G. (1981) · PubMed · Cited by 59
Locci, R., Peters, G., & Pulverer, G. (1981) · PubMed · Cited by 53
Cited by
A modified microtiter-plate test for quantification of staphylococcal biofilm formation
Stepanović, S., Vuković, D., Dakić, I., Savić, B., & Švabić-Vlahović, M. (2000) · Journal of Microbiological Methods · doi:10.1016/s0167-7012(00)00122-6 · Cited by 2,550
STEPANOVIĆ, S., VUKOVIĆ, D., HOLA, V., BONAVENTURA, G. D., DJUKIĆ, S., ĆIRKOVIĆ, I., & RUZICKA, F. (2007) · APMIS · doi:10.1111/j.1600-0463.2007.apm_630.x · Cited by 2,494
Ceri, H., Olson, M. E., Stremick, C., Read, R. R., Morck, D., & Buret, A. (1999) · Journal of Clinical Microbiology · doi:10.1128/jcm.37.6.1771-1776.1999 · Cited by 2,155
Comparison of multiple methods for quantification of microbial biofilms grown in microtiter plates
Peeters, E., Nelis, H. J., & Coenye, T. (2008) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2007.11.010 · Cited by 1,143
Growing and Analyzing Static Biofilms
Merritt, J. H., Kadouri, D. E., & O'Toole, G. A. (2006) · Current Protocols in Microbiology · doi:10.1002/9780471729259.mc01b01s00 · Cited by 1,086
Metadata
- Authors
- Christensen, G. D., Simpson, W. A., Younger, J. J., Baddour, L. M., Barrett, F. F., Melton, D. M., & Beachey, E. H.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1985-12
- Volume
- 22
- Issue
- 6
- Pages
- 996-1006
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W1929451968
- Cited by
- 2,255
- References
- 21
- FWCI
- 10.58
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.