Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 558

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Rapid and simple PCR assay for quantitation of human immunodeficiency virus type 1 RNA in plasma: application to acute retroviral infection

Open access
Mulder, J, McKinney, N, Christopherson, C, Sninsky, J, Greenfield, L, Kwok, S·1994·Journal of Clinical Microbiology

Abstract

A method for quantitating human immunodeficiency virus type 1 plasma viremia may be useful in monitoring disease progression and the responsiveness of patients to a therapeutic regimen or vaccine. A quantitative assay for viral RNA in plasma or sera that differs in several aspects from those reported previously was developed. First, whereas conventional reverse transcriptase-PCR assays involve a two-step process and use two enzymes, the method described uses a single enzyme, rTth DNA polymerase, for both reverse transcription and PCR. The reactions are carried out in a single tube and with a single buffer solution with uninterrupted thermal cycling. Second, uracil-N-glycosylase and dUTP are incorporated into the reaction mixtures to ensure that any carryover of DNA from previous amplifications will not compromise quantitation. Third, a quantitation standard is incorporated into each reaction mixture so that differences in amplification efficiency caused by sample interferents, variability in reaction conditions, or thermal cycling can be normalized. To ensure comparable amplification efficiency, the quantitation standard has the same primer-binding regions as the human immunodeficiency virus type 1 target and generates an amplified product of the same size and base composition. The probe-binding region was replaced with a sequence that can be detected separately. Fourth, a colorimetric detection format was modified to provide at least a four-log-unit dynamic range. The quantitative assay requires only a single amplification of the sample and can be completed in less than 8 h. The procedure was used on archival samples to demonstrate the viremic spike in acute infection and the suppressed levels of circulating virus following seroconversion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.32.2.292-300.1994

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 558

Metadata

Authors
Mulder, J., McKinney, N., Christopherson, C., Sninsky, J., Greenfield, L., & Kwok, S.
Venue
Journal of Clinical Microbiology
Published
1994-02
Volume
32
Issue
2
Pages
292-300
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W1618865275
Cited by
558
References
1
FWCI
21.35
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rapid and simple PCR assay for quantitation of human immunodeficiency virus type 1 RNA in plasma: application to acute retroviral infection. https://app.cochat.ai/papers/10.1128/jcm.32.2.292-300.1994
The paper
Mulder, J., McKinney, N., Christopherson, C., Sninsky, J., Greenfield, L., & Kwok, S. (1994). Rapid and simple PCR assay for quantitation of human immunodeficiency virus type 1 RNA in plasma: application to acute retroviral infection. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.32.2.292-300.1994

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.