Cited by 49Viral Infections and Outbreaks ResearchVirology and Viral DiseasesBiosensors and Analytical Detection

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Evaluation of ViroCyt® Virus Counter for Rapid Filovirus Quantitation

Open access

Abstract

Development and evaluation of medical countermeasures for diagnostics, vaccines, and therapeutics requires production of standardized, reproducible, and well characterized virus preparations. For filoviruses this includes plaque assay for quantitation of infectious virus, transmission electron microscopy (TEM) for morphology and quantitation of virus particles, and real-time reverse transcription PCR for quantitation of viral RNA (qRT-PCR). The ViroCyt® Virus Counter (VC) 2100 (ViroCyt, Boulder, CO, USA) is a flow-based instrument capable of quantifying virus particles in solution. Using a proprietary combination of fluorescent dyes that stain both nucleic acid and protein in a single 30 min step, rapid, reproducible, and cost-effective quantification of filovirus particles was demonstrated. Using a seed stock of Ebola virus variant Kikwit, the linear range of the instrument was determined to be 2.8E+06 to 1.0E+09 virus particles per mL with coefficient of variation ranging from 9.4% to 31.5% for samples tested in triplicate. VC particle counts for various filovirus stocks were within one log of TEM particle counts. A linear relationship was established between the plaque assay, qRT-PCR, and the VC. VC results significantly correlated with both plaque assay and qRT-PCR. These results demonstrated that the VC is an easy, fast, and consistent method to quantify filoviruses in stock preparations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/v7030857

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 2

  1. Stepp, 2010, New method for rapid virus quantification, Genet. Eng. Biotechnol. News, 30, 24
  2. Stepp, 2011, Comparing H1N1 virus quantification with a unique flow cytometer and quantitative PCR, BioProcess Int., 9, 50

Cited by

Sorted by citations

Metadata

Authors
Rossi, C., Kearney, B., Olschner, S., Williams, P., Robinson, C., Heinrich, M., Zovanyi, A., Ingram, M., Norwood, D., & Schoepp, R.
Affiliations
United States Army Medical Research Institute of Infectious Diseases (US)
Corresponding author
Rossi, Cynthia
Venue
Viruses
Publisher
MDPI AG
Published
2015-02-20
Volume
7
Issue
3
Pages
857-872
ISSN
1999-4915 (ISSN-L)
OpenAlex
W2148294427
Cited by
46
References
19
Citations by year
2025: 1 · 2024: 1 · 2023: 3 · 2022: 5 · 2021: 5 · 2020: 4 · 2019: 5 · 2018: 4 · 2017: 8 · 2016: 4 · 2015: 6
FWCI
5.70
Type
journal article
Language
en
Open access
Locations
  • Viruses (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Topics
  • Health Sciences › Medicine › Infectious Diseases › Viral Infections and Outbreaks Research
  • Health Sciences › Medicine › Epidemiology › Virology and Viral Diseases
  • Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
Keywords
flow cytometry, fluorescent dyes, Ebola virus, plaque assay, qRT-PCR, transmission electron microscopy, medical countermeasures
MeSH terms
Animals, Humans, Staining and Labeling, Time Factors, Viral Load, Ebolavirus

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review